Dependence of ablative ability of high-intensity focused ultrasound cavitation-based histotripsy on mechanical properties of agar.

Jin Xu1, Timothy A Bigelow2, Gabriel Davis1, Alex Avendano1, Pranav Shrotriya1, Kevin Bergler1, Zhong Hu2.   

Abstract

Cavitation-based histotripsy uses high-intensity focused ultrasound at low duty factor to create bubble clouds inside tissue to liquefy a region, and provides better fidelity to planned lesion coordinates and the ability to perform real-time monitoring. The goal of this study was to identify the most important mechanical properties for predicting lesion dimensions, among these three: Young's modulus, bending strength, and fracture toughness. Lesions were generated inside tissue-mimicking agar, and correlations were examined between the mechanical properties and the lesion dimensions, quantified by lesion volume and by the width and length of the equivalent bubble cluster. Histotripsy was applied to agar samples with varied properties. A cuboid of 4.5 mm width (lateral to focal plane) and 6 mm depth (along beam axis) was scanned in a raster pattern with respective step sizes of 0.75 and 3 mm. The exposure at each treatment location was either 15, 30, or 60 s. Results showed that only Young's modulus influenced histotripsy's ablative ability and was significantly correlated with lesion volume and bubble cluster dimensions. The other two properties had negligible effects on lesion formation. Also, exposure time differentially affected the width and depth of the bubble cluster volume.

Entities:  

Year:  2014        PMID: 25480051     DOI: 10.1121/1.4898426

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  7 in total

1.  Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh Samples Under Varying Scan Parameters.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu; Kamal M F Itani
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06       Impact factor: 2.725

2.  Enhanced Shock Scattering Histotripsy With Pseudomonopolar Ultrasound Pulses.

Authors:  Yige Li; Timothy L Hall; Zhen Xu; Charles A Cain
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-04-15       Impact factor: 2.725

3.  Visualizing the Histotripsy Process: Bubble Cloud-Cancer Cell Interactions in a Tissue-Mimicking Environment.

Authors:  Eli Vlaisavljevich; Adam Maxwell; Lauren Mancia; Eric Johnsen; Charles Cain; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2016-07-09       Impact factor: 2.998

4.  Post Hoc Analysis of Passive Cavitation Imaging for Classification of Histotripsy-Induced Liquefaction in Vitro.

Authors:  Kenneth B Bader; Kevin J Haworth; Adam D Maxwell; Christy K Holland
Journal:  IEEE Trans Med Imaging       Date:  2017-08-02       Impact factor: 10.048

5.  Impact of High-Intensity Ultrasound on Strength of Surgical Mesh When Treating Biofilm Infections.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu; Kamal M F Itani
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-14       Impact factor: 2.725

6.  Scan Parameter Optimization for Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-18       Impact factor: 2.725

7.  Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh Samples Under Varying Pulse Durations.

Authors:  Timothy A Bigelow; Clayton L Thomas; Huaiqing Wu; Kamal M F Itani
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-06-22       Impact factor: 2.725