Literature DB >> 25476128

Intra-operative deviation in limb alignment occurring at implantation in total knee arthroplasty.

D F Howie1, G J Love2, A H Deakin2, A W G Kinninmonth2.   

Abstract

BACKGROUND: Long-term survival of knee replacement depends on accurate alignment. Despite improvements in cut accuracy mal-alignment of 3° or more is still seen. All methods share common implantation techniques. This study examines the effect of implantation on overall limb alignment relating it to cut alignment and trial alignment.
METHODS: A retrospective review of navigated primary knee replacements was undertaken (n=113). Overall coronal limb alignments for the aggregated cuts, trial and final implanted components were examined.
RESULTS: All 113 knees had coronal aggregated cut alignment within 2° of neutral (range: 2° varus to 2° valgus). With trial components 99 knees (88%) had an overall coronal limb alignment within 2° of neutral (range: 3° varus to 4° valgus). After final implantation 106 knees (94%) were within 2° of neutral (range: 4° varus to 4° valgus). Forty eight knees (42%) showed no alignment deviation occurring between trial and the final implanted prostheses and 16 knees (14%) shoed a deviation of 2° or more. There was a correlation of both aggregated cut (r=0.284, p=0.002) and trial (r=0.794, p<0.001) with final alignment. There was no significant difference between the final alignment and the aggregated cut alignment(mean difference=-0.15°, p=0.254) or trial alignment (mean difference -0.13°, p=0.155).
CONCLUSIONS: Even when the aggregated alignment produced by the bone cuts is accurate, inaccuracy in final alignment can result from the implantation process. It may be productive for surgeons to concentrate on the implantation process to improve alignment and reduce outliers.
Copyright © 2014 Elsevier B.V. All rights reserved.

Keywords:  Alignment; Cement; Deviation; TKR

Mesh:

Year:  2014        PMID: 25476128     DOI: 10.1016/j.knee.2014.11.005

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  4 in total

1.  Technical and surgical causes of outliers after computer navigated total knee arthroplasty.

Authors:  Siddharth M Shah; Nadia C Sciberras; David J Allen; Frederic Picard
Journal:  J Orthop       Date:  2019-11-06

2.  A randomized controlled trial to compare component placement in navigated total knee arthroplasty using original and streamlined registration processes.

Authors:  Nadia C Sciberras; Mohammed Almustafa; Benjamin R K Smith; David J Allen; Frederic Picard; Angela H Deakin
Journal:  Arthroplast Today       Date:  2016-10-04

3.  Is Immediate Postoperative Mechanical Axis Associated with the Revision Rate of Primary Total Knee Arthroplasty? A 10-Year Follow-up Study.

Authors:  Ju-Kwon Park; Jong-Keun Seon; Kyu-Jin Cho; Nam-Hoon Lee; Eun-Kyoo Song
Journal:  Clin Orthop Surg       Date:  2018-05-18

4.  Alignment evaluation using different distal reference points after total knee arthroplasty.

Authors:  Yoshinori Ishii; Hideo Noguchi; Junko Sato; Ikuko Takahashi; Hana Ishii; Ryo Ishii; Kei Ishii; Shin-Ichi Toyabe
Journal:  J Orthop       Date:  2021-05-12
  4 in total