Literature DB >> 25473604

Open reduction internal fixation of distal clavicle fracture with supplementary button coracoclavicular fixation.

Andrew Hanflik1, Bryan T Hanypsiak2, Joshua Greenspoon3, Darren J Friedman4.   

Abstract

Distal clavicle fractures are common, and no standard treatment exists. Many different surgical modalities exist. This report describes an open reduction internal fixation technique that achieves both plate and coracoclavicular stabilization using a button device. A precontoured superior-lateral plate is secured to the clavicle. A 3.2-mm spade-tipped drill bit is drilled across the clavicle and coracoid, passing through 4 cortices. The button is loaded onto an insertion device, passed across the 4 cortices, and captured on the undersurface of the coracoid under fluoroscopic guidance. This construct is linked to the distal clavicle plate by heavy sutures using a second button that sits in the plate. The lateral locking holes are then filled to finalize fixation. This technique provides for a simplified way to achieve coracoclavicular stabilization when using a plate for fixation of distal clavicle fractures.

Entities:  

Year:  2014        PMID: 25473604      PMCID: PMC4246360          DOI: 10.1016/j.eats.2014.05.012

Source DB:  PubMed          Journal:  Arthrosc Tech        ISSN: 2212-6287


  8 in total

1.  Modified tension band fixation for unstable distal clavicle fractures.

Authors:  Jae-Myeung Chun; Soung-Yon Kim
Journal:  J Trauma       Date:  2011-05

2.  Fractures of the distal third of the clavicle.

Authors:  C S Neer
Journal:  Clin Orthop Relat Res       Date:  1968 May-Jun       Impact factor: 4.176

Review 3.  Treatment of distal clavicle fracture: a systematic review of treatment modalities in 425 fractures.

Authors:  Joo Han Oh; Sae Hoon Kim; Jung Ha Lee; Seung Han Shin; Hyun Sik Gong
Journal:  Arch Orthop Trauma Surg       Date:  2010-10-22       Impact factor: 3.067

4.  Simple, minimally invasive surgical technique for treatment of type 2 fractures of the distal clavicle.

Authors:  Ofer Levy
Journal:  J Shoulder Elbow Surg       Date:  2003 Jan-Feb       Impact factor: 3.019

5.  Fractures of the clavicle in the adult. Epidemiology and classification.

Authors:  C M Robinson
Journal:  J Bone Joint Surg Br       Date:  1998-05

6.  Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of type IIB distal clavicle fractures.

Authors:  Wes Madsen; Zaneb Yaseen; Russell LaFrance; Tony Chen; Hani Awad; Michael Maloney; Ilya Voloshin
Journal:  Arthroscopy       Date:  2013-06       Impact factor: 4.772

7.  Distal-third clavicle fracture fixation: a biomechanical evaluation of fixation.

Authors:  G Ryan Rieser; Kenny Edwards; Gregory C Gould; Ronald J Markert; Tarun Goswami; L Joseph Rubino
Journal:  J Shoulder Elbow Surg       Date:  2012-11-22       Impact factor: 3.019

8.  Surgical treatment of Neer type-II fractures of the distal clavicle: a meta-analysis.

Authors:  Sylvia A Stegeman; Hakan Nacak; Koen H J Huvenaars; Theo Stijnen; Pieta Krijnen; Inger B Schipper
Journal:  Acta Orthop       Date:  2013-03-19       Impact factor: 3.717

  8 in total
  4 in total

1.  Arthroscopic-Assisted Management of Unstable Distal-Third Clavicle Fractures: Conoid Ligament Reconstruction and Fracture Cerclage With Sutures.

Authors:  Luis Natera Cisneros; Juan Sarasquete Reiriz
Journal:  Arthrosc Tech       Date:  2015-11-09

2.  Management of unstable distal third clavicle fractures: clinical and radiological outcomes of the arthroscopy-assisted conoid ligament reconstruction and fracture cerclage with sutures.

Authors:  Luis Natera Cisneros; Juan Sarasquete Reiriz
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-02-22

3.  Innovative use of single-incision internal fixation of distal clavicle fractures augmented with coracoclavicular stabilisation.

Authors:  Rajpal Nandra; Tomasz Kowalski; Socrates Kalogrianitis
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-05-24

4.  Treatment of unstable distal-third clavicule fractures using minimal invasive closed-loop double endobutton technique.

Authors:  Yang Ruen Zheng; Yung Chang Lu; Chung Ting Liu
Journal:  J Orthop Surg Res       Date:  2019-01-31       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.