Literature DB >> 23726106

Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of type IIB distal clavicle fractures.

Wes Madsen1, Zaneb Yaseen, Russell LaFrance, Tony Chen, Hani Awad, Michael Maloney, Ilya Voloshin.   

Abstract

PURPOSE: The purpose of this study was to determine the effect of coracoclavicular (CC) fixation on biomechanical stability in type IIB distal clavicle fractures fixed with plate and screws.
METHODS: Twelve fresh-frozen matched cadaveric specimens were used to create type IIB distal clavicle fractures. Dual-energy x-ray absorptiometry (DEXA) scans ensured similar bone quality. Group 1 (6 specimens) was stabilized with a superior precontoured distal clavicle locking plate and supplemental suture anchor CC fixation. Group 2 (6 specimens) followed the same construct without CC fixation. Each specimen was cyclically loaded in the coronal plane at 40 to 80 N for 17,500 cycles. Load-to-failure testing was performed on the specimens that did not fail cyclic loading. Outcome measures included mode of failure and the number of cycles or load required to create 10 mm of displacement in the construct.
RESULTS: All specimens (12 of 12) completed cyclic testing without failure and underwent load-to-failure testing. Group 1 specimens failed at a mean of 808.5 N (range, 635.4 to 952.3 N), whereas group 2 specimens failed at a mean of 401.3 N (range, 283.6 to 656.0 N) (P = .005). Group 1 specimens failed by anchor pullout without coracoid fracture (4 of 6) and distal clavicle fracture fragment fragmentation (1 of 6); one specimen did not fail at the maximal load the materials testing machine was capable of exerting (1,000 N). Group 2 specimens failed by distal clavicle fracture fragment fragmentation (3 of 6) and acromioclavicular (AC) joint displacement (1 of 6); 2 specimens did not fail at the maximal load of the materials testing machine.
CONCLUSIONS: During cyclic loading, type IIB distal clavicle fractures with and without CC fixation remain stable. CC fixation adds stability to type IIB distal clavicle fractures fixed with plate and screws when loaded to failure. CLINICAL RELEVANCE: CC fixation for distal clavicle fractures is a useful adjunct to plate-and-screw fixation to augment stability of the fracture.
Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23726106     DOI: 10.1016/j.arthro.2013.02.024

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  20 in total

1.  What Regions of the Distal Clavicle Have the Greatest Bone Mineral Density and Cortical Thickness? A Cadaveric Study.

Authors:  Raymond E Chen; Sandeep P Soin; Rami El-Shaar; Gregg T Nicandri; Hani A Awad; Michael D Maloney; Ilya Voloshin
Journal:  Clin Orthop Relat Res       Date:  2019-12       Impact factor: 4.176

2.  Lateral clavicle fracture with coracoclavicular ligament injury: a biomechanical study of 4 different repair techniques.

Authors:  Farhang Alaee; John Apostolakos; Hardeep Singh; Christian Holwein; Theresa Diermeier; Mark P Cote; Knut Beitzel; Andreas B Imhoff; Augustus D Mazzocca; Andreas Voss
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-02-14       Impact factor: 4.342

3.  Arthroscopic-Assisted Management of Unstable Distal-Third Clavicle Fractures: Conoid Ligament Reconstruction and Fracture Cerclage With Sutures.

Authors:  Luis Natera Cisneros; Juan Sarasquete Reiriz
Journal:  Arthrosc Tech       Date:  2015-11-09

Review 4.  [Distal clavicle fractures. Classifications and management].

Authors:  Ben Ockert; E Wiedemann; F Haasters
Journal:  Unfallchirurg       Date:  2015-05       Impact factor: 1.000

5.  Management of unstable distal third clavicle fractures: clinical and radiological outcomes of the arthroscopy-assisted conoid ligament reconstruction and fracture cerclage with sutures.

Authors:  Luis Natera Cisneros; Juan Sarasquete Reiriz
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-02-22

6.  Innovative use of single-incision internal fixation of distal clavicle fractures augmented with coracoclavicular stabilisation.

Authors:  Rajpal Nandra; Tomasz Kowalski; Socrates Kalogrianitis
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-05-24

Review 7.  Fracture of distal end clavicle: A review.

Authors:  Balaji Sambandam; Rajat Gupta; Santosh Kumar; Lalit Maini
Journal:  J Clin Orthop Trauma       Date:  2014-06-19

8.  Open reduction internal fixation of distal clavicle fracture with supplementary button coracoclavicular fixation.

Authors:  Andrew Hanflik; Bryan T Hanypsiak; Joshua Greenspoon; Darren J Friedman
Journal:  Arthrosc Tech       Date:  2014-09-01

9.  [Clavicular hook plate with coracoclavicular ligament augmentation by suture anchor in the treatment of unstable distal clavicle fractures].

Authors:  Shuang Wu; Jialei Chen; Jie Zhang; Shakya Sujan; Fei Xing; Zhou Xiang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-08-15

10.  The use of Tightrope device as the sole method of fixation in treating lateral end clavicle fractures.

Authors:  K Al-Tawil; M Garner; T Antonios; K Karrupaiah; R Tahmassebi; T Colegate-Stone; A Tavakkolizadeh
Journal:  Shoulder Elbow       Date:  2020-10-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.