| Literature DB >> 25473516 |
Esther N Maxkwee1, Jennifer J Perry2, Ken Lee1.
Abstract
Raw eggs are a potential health hazard and a new federally approved process uses ozone to maintain freshness while ensuring safety. The impact of an ozone process on the flavor, color, and shell integrity of eggs must be known for market acceptance. The visual perception and consumer acceptance of full commercial scale ozone-pasteurized eggs are reported, using a degree of liking test and a Just-About-Right analysis. Instrumental analysis of albumen turbidity, yolk color, and Haugh Units correlate with human perception. Visual tests reveal that ozone-pasteurized eggs were equivalent to thermally pasteurized eggs in attributes such as appearance, spread, and cloudiness. They were equivalent to untreated eggs in yolk height, yellowness, and appeal. There were no differences in taste among all egg treatments for measures of aroma, flavor, texture and overall liking. Ozone-pasteurized eggs have the same appeal as raw eggs, and can be cooked without flavor loss. This promising new ozone process maintains good sensory quality relative to thermal processing.Entities:
Keywords: Acceptance; egg; ozone; pasteurization; sensory
Year: 2014 PMID: 25473516 PMCID: PMC4237488 DOI: 10.1002/fsn3.134
Source DB: PubMed Journal: Food Sci Nutr ISSN: 2048-7177 Impact factor: 2.863
Figure 1Visual ratings of three egg treatments by 98 consumers viewing the freshly cracked, uncooked contents over a black matte background. Ratings are a linear 10-point scale with the endpoint descriptive anchors at 1 and 10 listed at left. (a–c) Within each group of three bars a different letter indicates a significant difference at P > 0.05. Error lines show one standard error of the mean.
Figure 2Consumer scores (n = 98) on a Just-About-Right (JAR) rating of scrambled eggs by three treatments for (A) Color, (B) Moistness, and (C) Texture.
Physical properties of egg quality before (raw) and after processing (ozone). Haugh Unit expressed as HU = 100 log10 (h − 1.7w0.37 + 7.6) is increased, while tristimulus colorimeter measures of value, hue and chroma, or L*, a*, b*, respectively, show no significant color change. Turbidity by optical density increased.
| Physical property | Before processing, raw | After ozone processing | |
|---|---|---|---|
| Haugh unit, HU | 10 | 85.6 ± 2.700b | 92.2 ± 1.220a |
| 10 | 61.7 ± 0.440a | 62.4 ± 0.370a | |
| 10 | 12.2 ± 0.230a | 12.2 ± 0.290a | |
| 10 | 57.1 ± 0.600a | 57.5 ± 0.340a | |
| Turbidity, OD | 12 | 0.020 ± 0.010b | 0.321 ± 0.040a |
Mean ± standard error of mean. Within each row, different letters indicate a significant difference at α = 0.05.