Few-view cone-beam CT reconstruction with deformed prior image.

Hua Zhang1, Luo Ouyang2, Jing Huang3, Jianhua Ma3, Wufan Chen3, Jing Wang2.   

Abstract

PURPOSE: Prior images can be incorporated into the image reconstruction process to improve the quality of subsequent cone-beam CT (CBCT) images from sparse-view or low-dose projections. The purpose of this work is to develop a deformed prior image-based reconstruction (DPIR) strategy to mitigate the deformation between the prior image and the target image.
METHODS: The deformed prior image is obtained by a projection-based registration approach. Specifically, the deformation vector fields used to deform the prior image are estimated through iteratively matching the forward projection of the deformed prior image and the measured on-treatment projections. The deformed prior image is then used as the prior image in the standard prior image constrained compressed sensing (PICCS) algorithm. A simulation study on an XCAT phantom and a clinical study on a head-and-neck cancer patient were conducted to evaluate the performance of the proposed DPIR strategy.
RESULTS: The deformed prior image matches the geometry of the on-treatment CBCT more closely as compared to the original prior image. Consequently, the performance of the DPIR strategy from few-view projections is improved in comparison to the standard PICCS algorithm, based on both visual inspection and quantitative measures. In the XCAT phantom study using 20 projections, the average root mean squared error is reduced from 14% in PICCS to 10% in DPIR, and the average universal quality index increases from 0.88 in PICCS to 0.92 in DPIR.
CONCLUSIONS: The present DPIR approach provides a practical solution to the mismatch problem between the prior image and target image, which improves the performance of the original PICCS algorithm for CBCT reconstruction from few-view or low-dose projections.

Entities:  

Mesh:

Year:  2014        PMID: 25471965     DOI: 10.1118/1.4901265

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Robust dynamic myocardial perfusion CT deconvolution for accurate residue function estimation via adaptive-weighted tensor total variation regularization: a preclinical study.

Authors:  Dong Zeng; Changfei Gong; Zhaoying Bian; Jing Huang; Xinyu Zhang; Hua Zhang; Lijun Lu; Shanzhou Niu; Zhang Zhang; Zhengrong Liang; Qianjin Feng; Wufan Chen; Jianhua Ma
Journal:  Phys Med Biol       Date:  2016-10-26       Impact factor: 3.609

2.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

3.  Generalizable cone beam CT esophagus segmentation using physics-based data augmentation.

Authors:  Sadegh R Alam; Tianfang Li; Pengpeng Zhang; Si-Yuan Zhang; Saad Nadeem
Journal:  Phys Med Biol       Date:  2021-03-04       Impact factor: 3.609

4.  Motion guided Spatiotemporal Sparsity for high quality 4D-CBCT reconstruction.

Authors:  Yang Liu; Xi Tao; Jianhua Ma; Zhaoying Bian; Dong Zeng; Qianjin Feng; Wufan Chen; Hua Zhang
Journal:  Sci Rep       Date:  2017-12-12       Impact factor: 4.379

5.  Augmented laminography, a correlative 3D imaging method for revealing the inner structure of compressed fossils.

Authors:  Marcus Zuber; Michael Laaß; Elias Hamann; Sophie Kretschmer; Norbert Hauschke; Thomas van de Kamp; Tilo Baumbach; Thomas Koenig
Journal:  Sci Rep       Date:  2017-01-27       Impact factor: 4.379

6.  Effectiveness of Non-Local Means Algorithm with an Industrial 3 MeV LINAC High-Energy X-Ray System for Non-Destructive Testing.

Authors:  Kyuseok Kim; Jaegu Choi; Youngjin Lee
Journal:  Sensors (Basel)       Date:  2020-05-05       Impact factor: 3.576

7.  Performance of sparse-view CT reconstruction with multi-directional gradient operators.

Authors:  Chia-Jui Hsieh; Shih-Chun Jin; Jyh-Cheng Chen; Chih-Wei Kuo; Ruei-Teng Wang; Woei-Chyn Chu
Journal:  PLoS One       Date:  2019-01-07       Impact factor: 3.240

8.  Fully Automatic Sliding Motion Compensated and Simultaneous 4D-CBCT via Bilateral Filtering.

Authors:  Jun Dang; Tao You; Wenzheng Sun; Hanguan Xiao; Longhao Li; Xiaopin Chen; Chunhua Dai; Ying Li; Yanbo Song; Tao Zhang; Deyu Chen
Journal:  Front Oncol       Date:  2021-01-18       Impact factor: 6.244

9.  Blind Deconvolution Based on Compressed Sensing with bi-l0-l2-norm Regularization in Light Microscopy Image.

Authors:  Kyuseok Kim; Ji-Youn Kim
Journal:  Int J Environ Res Public Health       Date:  2021-02-12       Impact factor: 3.390

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.