| Literature DB >> 25466365 |
Mulugeta Belay1,2, Mengistu Legesse3, Daniel Dagne4,5, Adane Mihret6, Yonas Bekele7, Girmay Medhin8, Gunnar Bjune9, Fekadu Abebe10.
Abstract
BACKGROUND: QuantiFERON-TB Gold In-Tube® (QFT-GIT) test is used for the diagnosis of latent tuberculosis (TB) infection. Besides, QFT-GIT test could allow tracking changes in immune response among TB patients and their contacts. In high TB burden settings, reports on QFT-GIT conversions and reversions among TB patients and their contacts are limited. As part of a major project to study immune responses to TB infection, we investigated QFT-GIT test conversions and reversions among smear positive pulmonary TB patients and their household contacts over 12 months.Entities:
Mesh:
Year: 2014 PMID: 25466365 PMCID: PMC4264256 DOI: 10.1186/s12879-014-0654-5
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Comparison of QFT-GIT test results at baseline and 12 months among contacts and patients
| Patients | Contacts | |||
|---|---|---|---|---|
| n(%) | n(%) | |||
| Baseline | 12 months | Baseline | 12 months | |
| QFT-GIT-negative | 7 (21.9*) | 6 (18.8*) | 24 (32.4) | 14 (18.9) |
| QFT-GIT-positive | 25 (78.1*) | 26 (81.2*) | 50 (67.6) |
|
| McNemar, p-value | 1.00 | 0.006 | ||
*One patient with indeterminate result at baseline was excluded from the denominator.
One QFT-GIT positive contact at baseline became negative at 12 months and hence the total QFT-GIT positive contacts at 12 months were 60 instead of 61 (50 + 11).
Figure 1Comparison of median levels of IFN-γ at baseline and 12 months later among patients (n = 32) and contacts (n = 74). Wilcoxon matched-pairs signed rank test was used to analyze the data. Each filled circle represents a participant and the horizontal solid lines represent medians. The median level of IFN-γ among contacts was significantly increased at 12 months compared to baseline level but among patients, there was no significant difference.
Figure 2Comparison of the median levels of IFN-γ between patients (n = 32) and contacts (n = 74) at baseline and 12 months. Mann-Whitney test was used to analyze the data. Each filled circle represents a participant and horizontal solid lines represent medians. There was no statistically significant difference in the median levels of IFN-γ between patients and contacts both at baseline and 12 months later.
Levels of IFN-γ at baseline and 12 months later among QFT-GIT negative contacts at baseline
| Participant | IFN-γ (IU/ml) | IFN-γ (IU/ml) | QFT-GIT result at 12 months |
|---|---|---|---|
| at baseline | at 12 months | ||
|
| |||
| 1 | 0.00 | 0.05 | Negative |
| 2 | 0.02 | 0.02 | Negative |
| 3 | 0.12 | 0.21 | Negative |
| 4 | 0.03 | 0.03 | Negative |
| 5 | 0.00 | 0.34 | Negative |
| 6 | 0.00 | 0.00 | Negative |
| 7 | 0.00 | 0.04 | Negative |
| 8 | 0.00 | 0.08 | Negative |
| 9 | 0.00 | 0.03 | Negative |
| 10 | 0.06 | 0.17 | Negative |
| 11 | 0.00 | 0.00 | Negative |
| 12 | 0.01 | 0.00 | Negative |
| 13 | 0.00 | 0.03 | Negative |
|
| |||
| 14 | 0.19 | 0.53 | Positive |
| 15 | 0.28 | 0.57 | Positive |
| 16 | 0.21 | 1.15 | Positive |
| 17 | 0.00 | 2.19 | Positive |
| 18 | 0.02 | 2.27 | Positive |
| 19 | 0.03 | 2.47 | Positive |
| 20 | 0.01 | 2.68 | Positive |
| 21 | 0.08 | 4.31 | Positive |
| 22 | 0.02 | 4.52 | Positive |
| 23 | 0.04 | 5.54 | Positive |
| 24 | 0.00 | 8.94 | Positive |
Contacts from number 1 to 13 (n = 13) were QFT-GIT negative both at baseline and at 12 months with low IFN-γ response whereas contacts from number 14 to 24 (n = 11) were negative at baseline but became positive at 12 months. Nine of the 11 contacts with QFT-GIT test conversions had high IFN-γ response at 12 months whereas 2 (number 14 and 15) of them had IFN-γ values close to the cut-off (0.35).