Literature DB >> 25462359

Rapid detection and isotopic measurement of discrete inorganic samples using acoustically actuated droplet ejection and extractive electrospray ionization mass spectrometry.

Thomas P Forbes1.   

Abstract

RATIONALE: The rapid detection, screening, and isotopic signature analysis of inorganics provide invaluable information for a variety of applications including explosive device detection, nuclear forensics, and environmental monitoring. The coupling of ultrasonic nebulization and extractive electrospray ionization (EESI) enabled the mass spectrometric (MS) detection and analysis of inorganics from microliter sample solution aliquots.
METHODS: Ultrasonic nebulization and acoustic pressure wave focusing within an array of exponential horn structures were utilized for the efficient atomization of discrete liquid samples ranging in volume from 3 μL to 10 μL pipetted aliquots. In conjunction with an electro-flow focusing source for extractive electrospray ionization (EESI), in-source collision-induced dissociation (CID) was utilized to enhance inorganic detection through fragmentation of adducts and reduction in chemical noise from organic compounds.
RESULTS: The investigated system enhanced detection of the singly charged elemental cation species and provided accurate measurements of isotopic distributions for a number of metal ions. The extent of CID demonstrated the competition between ligand loss from hydrate clusters and charge reduction from the doubly charged to singly charged cations for the alkaline earth metal ions of strontium and barium. Inorganics were also detected from complex matrices, including synthetic fingerprint material and sediment, without detriment to device operation.
CONCLUSIONS: The described system provides a versatile tool for the rapid detection, speciation, and isotopic identification of inorganic compounds at nanogram to sub-nanogram levels from microliter aliquots. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.

Entities:  

Year:  2015        PMID: 25462359     DOI: 10.1002/rcm.7074

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  5 in total

1.  DART-MS analysis of inorganic explosives using high temperature thermal desorption.

Authors:  Thomas P Forbes; Edward Sisco; Matthew Staymates; Greg Gillen
Journal:  Anal Methods       Date:  2017-05-04       Impact factor: 2.896

2.  Enhanced aerodynamic reach of vapor and aerosol sampling for real-time mass spectrometric detection using Venturi-assisted entrainment and ionization.

Authors:  Thomas P Forbes; Matthew Staymates
Journal:  Anal Chim Acta       Date:  2017-01-02       Impact factor: 6.558

Review 3.  Recent advances in ambient mass spectrometry of trace explosives.

Authors:  Thomas P Forbes; Edward Sisco
Journal:  Analyst       Date:  2018-04-30       Impact factor: 4.616

Review 4.  Recent advances in acoustic microfluidics and its exemplary applications.

Authors:  Yue Li; Shuxiang Cai; Honglin Shen; Yibao Chen; Zhixing Ge; Wenguang Yang
Journal:  Biomicrofluidics       Date:  2022-06-13       Impact factor: 3.258

5.  The onset of electrospray: the universal scaling laws of the first ejection.

Authors:  A M Gañán-Calvo; J M López-Herrera; N Rebollo-Muñoz; J M Montanero
Journal:  Sci Rep       Date:  2016-09-01       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.