Literature DB >> 29651308

DART-MS analysis of inorganic explosives using high temperature thermal desorption.

Thomas P Forbes1, Edward Sisco1, Matthew Staymates1, Greg Gillen1.   

Abstract

Chemical">An ambient mass spectrometry (MS) platform coupling resistive Joule heating thermal desorption (JHTD) Chemical">and direct Chemical">analysis in real time (DART) was implemented for the Chemical">analysis of inorgChemical">anic Chemical">an class="Chemical">nitrite, nitrate, chlorate, and perchlorate salts. The resistive heating component generated discrete and rapid heating ramps and elevated temperatures, up to approximately 400 °C s-1 and 750 °C, by passing a few amperes of DC current through a nichrome wire. JHTD enhanced the utility and capabilities of traditional DART-MS for the trace detection of previously difficult to detect inorganic compounds. A partial factorial design of experiments (DOE) was implemented for the systematic evaluation of five system parameters. A base set of conditions for JHTD-DART-MS was derived from this evaluation, demonstrating sensitive detection of a range of inorganic oxidizer salts, down to single nanogram levels. DOE also identified JHTD filament current and in-source collision induced dissociation (CID) energy as inducing the greatest effect on system response. Tuning of JHTD current provided a method for controlling the relative degrees of thermal desorption and thermal decomposition. Furthermore, in-source CID provided manipulation of adduct and cluster fragmentation, optimizing the detection of molecular anion species. Finally, the differential thermal desorption nature of the JHTD-DART platform demonstrated efficient desorption and detection of organic and inorganic explosive mixtures, with each desorbing at its respective optimal temperature.

Entities:  

Year:  2017        PMID: 29651308      PMCID: PMC5890339          DOI: 10.1039/C7AY00867H

Source DB:  PubMed          Journal:  Anal Methods        ISSN: 1759-9660            Impact factor:   2.896


  30 in total

1.  Forensic identification of explosive oxidizers by electrospray ionization mass spectrometry.

Authors:  Xiaoming Zhao; Jehuda Yinon
Journal:  Rapid Commun Mass Spectrom       Date:  2002       Impact factor: 2.419

Review 2.  Desorption electrospray ionization and other ambient ionization methods: current progress and preview.

Authors:  Demian R Ifa; Chunping Wu; Zheng Ouyang; R Graham Cooks
Journal:  Analyst       Date:  2010-03-02       Impact factor: 4.616

3.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

4.  Screening for trace explosives by AccuTOF™-DART®: an in-depth validation study.

Authors:  Edward Sisco; Jeffrey Dake; Candice Bridge
Journal:  Forensic Sci Int       Date:  2013-08-17       Impact factor: 2.395

5.  Ambient sampling/ionization mass spectrometry: applications and current trends.

Authors:  Glenn A Harris; Asiri S Galhena; Facundo M Fernández
Journal:  Anal Chem       Date:  2011-05-06       Impact factor: 6.986

6.  Towards universal ambient ionization: direct elemental analysis of solid substrates using microwave plasma ionization.

Authors:  K M Evans-Nguyen; J Gerling; H Brown; M Miranda; A Windom; J Speer
Journal:  Analyst       Date:  2016-03-16       Impact factor: 4.616

7.  Integrated explosive preconcentrator and electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vapor.

Authors:  Karel Cizek; Chad Prior; Chongdee Thammakhet; Michal Galik; Kevin Linker; Ray Tsui; Avi Cagan; John Wake; Jeff La Belle; Joseph Wang
Journal:  Anal Chim Acta       Date:  2009-12-16       Impact factor: 6.558

8.  Rapid detection of sugar alcohol precursors and corresponding nitrate ester explosives using direct analysis in real time mass spectrometry.

Authors:  Edward Sisco; Thomas P Forbes
Journal:  Analyst       Date:  2015-02-26       Impact factor: 4.616

9.  Global optimization of the infrared matrix-assisted laser desorption electrospray ionization (IR MALDESI) source for mass spectrometry using statistical design of experiments.

Authors:  Jeremy A Barry; David C Muddiman
Journal:  Rapid Commun Mass Spectrom       Date:  2011-12-15       Impact factor: 2.419

10.  Reagent approaches for improved detection of chlorate and perchlorate salts via thermal desorption and ionization.

Authors:  Jude A Kelley; Alla Ostrinskaya; Geoff Geurtsen; Roderick R Kunz
Journal:  Rapid Commun Mass Spectrom       Date:  2016-01-15       Impact factor: 2.419

View more
  9 in total

1.  Forensic Analysis and Differentiation of Black Powder and Black Powder Substitute Chemical Signatures by Infrared Thermal Desorption-DART-MS.

Authors:  Thomas P Forbes; Jennifer R Verkouteren
Journal:  Anal Chem       Date:  2018-12-14       Impact factor: 6.986

2.  Detection of Nonvolatile Inorganic Oxidizer-Based Explosives from Wipe Collections by Infrared Thermal Desorption-Direct Analysis in Real Time Mass Spectrometry.

Authors:  Thomas P Forbes; Edward Sisco; Matthew Staymates
Journal:  Anal Chem       Date:  2018-05-07       Impact factor: 6.986

3.  Emerging techniques for the detection of pyrotechnic residues from seized postal packages containing fireworks.

Authors:  Karlijn D B Bezemer; Thomas P Forbes; Annemieke W C Hulsbergen; Jennifer Verkouteren; Shannon T Krauss; Mattijs Koeberg; Peter J Schoenmakers; Greg Gillen; Arian C van Asten
Journal:  Forensic Sci Int       Date:  2020-01-24       Impact factor: 2.395

4.  Considerations for uranium isotope ratio analysis by atmospheric pressure ionization mass spectrometry.

Authors:  Thomas P Forbes; Christopher Szakal
Journal:  Analyst       Date:  2018-12-17       Impact factor: 4.616

5.  A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks.

Authors:  Nicholas Drury; Robert Ramotowski; Mehdi Moini
Journal:  Forensic Sci Int       Date:  2018-05-24       Impact factor: 2.395

Review 6.  Recent advances in ambient mass spectrometry of trace explosives.

Authors:  Thomas P Forbes; Edward Sisco
Journal:  Analyst       Date:  2018-04-30       Impact factor: 4.616

Review 7.  Interpol review of detection and characterization of explosives and explosives residues 2016-2019.

Authors:  Douglas J Klapec; Greg Czarnopys; Julie Pannuto
Journal:  Forensic Sci Int       Date:  2020-06-17       Impact factor: 2.395

8.  Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives.

Authors:  Lauren Pintabona; Alina Astefanei; Garry L Corthals; Arian C van Asten
Journal:  J Am Soc Mass Spectrom       Date:  2019-10-28       Impact factor: 3.109

9.  Rapid geographical indication of peppercorn seeds using corona discharge mass spectrometry.

Authors:  Preeyarad Charoensumran; Monrawat Rauytanapanit; Nontawat Sricharoen; Barry L Smith; Kanet Wongravee; Simon Maher; Thanit Praneenararat
Journal:  Sci Rep       Date:  2021-08-09       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.