Literature DB >> 25460404

Uniaxial and biaxial mechanical properties of porcine linea alba.

Gerard M Cooney1, Kevin M Moerman2, Michael Takaza3, Des C Winter4, Ciaran K Simms5.   

Abstract

Incisional hernia is a severe complication post-laparoscopic/laparotomy surgery that is commonly associated with the linea alba. However, the few studies on the mechanical properties of the linea alba in the literature appear contradictory, possible due to challenges with the physical dimensions of samples and variations in protocol. This study focuses on the tensile mechanical characterisation of the porcine linea alba, as determined by uniaxial and equi-load biaxial testing using image-based strain measurement methods. Results show that the linea alba demonstrated a non-linear elastic, anisotropic behaviour which is often observed in biological soft tissues. The transverse direction (parallel to fibres) was found to be approximately eight times stiffer than the longitudinal (cross-fibre) direction under both uniaxial and equi-load biaxial loading. The equi-load biaxial tensile tests revealed that contraction could occur in the transverse direction despite increasing load, probably due to the anisotropy of the tissue. Optical surface marker tracking and digital image correlation methods were found to greatly improve the accuracy of stretch measurement, resulting in a 75% change in the apparent stiffness compared to using strain derived from machine cross-head displacement. Additionally, a finite element model of the experiments using a combination of an Ogden and fibre exponential power law model for the linea alba was implemented to quantify the effect of clamping and tissue dimensions (which are suboptimal for tensile testing) on the results. The preliminary model results were used to apply a correction factor to the uniaxial experimental data prior to inverse optimisation to derive best fit material parameters for the fibre reinforced Ogden model. Application of the model to the equi-load biaxial case showed some differences compared to the experimental data, suggesting a more complex anisotropic model may be necessary to capture biaxial behaviour. These results provide an improved assessment of the mechanical properties of the porcine linea alba for wound closure and other studies.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biaxial tension; FEBio model; Linea alba; Physical sample size effect; Uniaxial tension

Mesh:

Year:  2014        PMID: 25460404     DOI: 10.1016/j.jmbbm.2014.09.026

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  3 in total

1.  Skin wrinkles and folds enable asymmetric stretch in the elephant trunk.

Authors:  Andrew K Schulz; Madeline Boyle; Colin Boyle; Sophia Sordilla; Catalina Rincon; Scott Hooper; Catie Aubuchon; Joy S Reidenberg; Claire Higgins; David L Hu
Journal:  Proc Natl Acad Sci U S A       Date:  2022-07-18       Impact factor: 12.779

2.  The influence of different sample preparation on mechanical properties of human iliotibial tract.

Authors:  Benjamin Fischer; Sascha Kurz; Andreas Höch; Stefan Schleifenbaum
Journal:  Sci Rep       Date:  2020-09-09       Impact factor: 4.379

3.  Mechanical and structural characterisation of the dural venous sinuses.

Authors:  Darragh R Walsh; James J Lynch; David T O' Connor; David T Newport; John J E Mulvihill
Journal:  Sci Rep       Date:  2020-12-10       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.