Literature DB >> 25459035

Percutaneous left atrial appendage closure: procedural techniques and outcomes.

Jacqueline Saw1, Mathieu Lempereur2.   

Abstract

Percutaneous left atrial appendage closure technology for stroke prevention in patients with atrial fibrillation has significantly advanced in the past 2 decades. Several devices are under clinical investigation, and a few have already received Conformité Européene (CE)-mark approval and are available in many countries. The WATCHMAN device (Boston Scientific, Natick, Massachusetts) has the most supportive data and is under evaluation by the U.S. Food and Drug Administration for warfarin-eligible patients. The Amplatzer Cardiac Plug (St. Jude Medical, Plymouth, Minnesota) has a large real-world experience over the past 5 years, and a randomized trial comparing Amplatzer Cardiac Plug with the WATCHMAN device is anticipated in the near future. The Lariat procedure (SentreHEART Inc., Redwood City, California) has also gained interest lately, but early studies were concerning for high rates of serious pericardial effusion and major bleeding. The current real-world experience predominantly involves patients who are not long-term anticoagulation candidates or who are perceived to have high bleeding risks. This pattern of practice is expected to change when the U.S. Food and Drug Administration approves the WATCHMAN device for warfarin-eligible patients. This paper reviews in depth the procedural techniques, safety, and outcomes of the current leading devices.
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Amplatzer Cardiac Plug; Amulet; Lariat; WATCHMAN; left atrial appendage closure

Mesh:

Year:  2014        PMID: 25459035     DOI: 10.1016/j.jcin.2014.05.026

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  37 in total

1.  Efficacy and safety of percutaneous left atrial appendage closure to prevent thromboembolic events in atrial fibrillation patients with high stroke and bleeding risk.

Authors:  Julia Seeger; Carlo Bothner; Tillman Dahme; Birgid Gonska; Dominik Scharnbeck; Sinisa Markovic; Wolfgang Rottbauer; Jochen Wöhrle
Journal:  Clin Res Cardiol       Date:  2015-08-30       Impact factor: 5.460

2.  Early results of first versus second generation Amplatzer occluders for left atrial appendage closure in patients with atrial fibrillation.

Authors:  Steffen Gloekler; Samera Shakir; Janosch Doblies; Ahmed A Khattab; Fabien Praz; Ênio Guerios; Dezsoe Koermendy; Stefan Stortecky; Thomas Pilgrim; Lutz Buellesfeld; Peter Wenaweser; Stephan Windecker; Aris Moschovitis; Milosz Jaguszewski; Ulf Landmesser; Fabian Nietlispach; Bernhard Meier
Journal:  Clin Res Cardiol       Date:  2015-03-04       Impact factor: 5.460

Review 3.  CT support of cardiac structural interventions.

Authors:  Michaela M Hell; Stephan Achenbach
Journal:  Br J Radiol       Date:  2019-03-11       Impact factor: 3.039

4.  The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder.

Authors:  Dan Jia; Qing Zhou; Hong-Ning Song; Lan Zhang; Jin-Ling Chen; Yu Liu; Bin Kong; Fa-Zhi He; Yi-Jia Wang; Yuan-Ting Yang
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-27       Impact factor: 2.357

5.  Procedural success and intra-hospital outcome related to left atrial appendage morphology in patients that receive an interventional left atrial appendage closure.

Authors:  Christian Fastner; Michael Behnes; Benjamin Sartorius; Annika Wenke; Ibrahim El-Battrawy; Uzair Ansari; Ishar-Singh Gill; Martin Borggrefe; Ibrahim Akin
Journal:  Clin Cardiol       Date:  2017-04-13       Impact factor: 2.882

6.  Feasibility of intracardiac echocardiography imaging from the left superior pulmonary vein for left atrial appendage occlusion.

Authors:  Do Young Kim; Seung Yong Shin; Jin-Seok Kim; Seong Hwan Kim; Young-Hoon Kim; Hong Euy Lim
Journal:  Int J Cardiovasc Imaging       Date:  2018-05-22       Impact factor: 2.357

7.  Patient specific 3D print of left atrial appendage for closure device.

Authors:  Edinrin Obasare; Emmanuel Melendres; D Lynn Morris; Sumeet K Mainigi; Gregg S Pressman
Journal:  Int J Cardiovasc Imaging       Date:  2016-07-06       Impact factor: 2.357

Review 8.  Strategies for Recovering an Embolized Percutaneous Device.

Authors:  Thomas Nestelberger; Mesfer Alfadhel; Cameron McAlister; Rohit Samuel; Jacqueline Saw
Journal:  Curr Cardiol Rep       Date:  2021-07-16       Impact factor: 2.931

Review 9.  Left Atrial Occlusion Device Implantation: the Role of the Echocardiographer.

Authors:  David Altszuler; Alan F Vainrib; Daniel G Bamira; Ricardo J Benenstein; Anthony Aizer; Larry A Chinitz; Muhamed Saric
Journal:  Curr Cardiol Rep       Date:  2019-06-10       Impact factor: 2.931

Review 10.  Left Atrial Appendage Closure for Stroke Prevention in Atrial Fibrillation.

Authors:  Erin A Fender; Jawad G Kiani; David R Holmes
Journal:  Curr Atheroscler Rep       Date:  2016-11       Impact factor: 5.113

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.