A comparison of phantom scatter from flattened and flattening filter free high-energy photon beams.

Neil Richmond1, Vince Allen2, Jim Daniel3, Rob Dacey2, Chris Walker3.   

Abstract

Flattening filter free (FFF) photon beams have different dosimetric properties from those of flattened beams. The aim of this work was to characterize the collimator scatter (Sc) and total scatter (Scp) from 3 FFF beams of differing quality indices and use the resulting mathematical fits to generate phantom scatter (Sp) data. The similarities and differences between Sp of flattened and FFF beams are described. Sc and Scp data were measured for 3 flattened and 3 FFF high-energy photon beams (Varian 6 and 10MV and Elekta 6MV). These data were fitted to logarithmic power law functions with 4 numerical coefficients. The agreement between our experimentally determined flattened beam Sp and published data was within ± 1.2% for all 3 beams investigated and all field sizes from 4 × 4 to 40 × 40cm(2). For the FFF beams, Sp was only within 1% of the same flattened beam published data for field sizes between 6 × 6 and 14 × 14cm(2). Outside this range, the differences were much greater, reaching - 3.2%, - 4.5%, and - 4.3% for the fields of 40 × 40cm(2) for the Varian 6-MV, Varian 10-MV, and Elekta 6-MV FFF beams, respectively. The FFF beam Sp increased more slowly with increasing field size than that of the published and measured flattened beam of a similar reference field size quality index, i.e., there is less Phantom Scatter than that found with flattened beams for a given field size. This difference can be explained when the fluence profiles of the flattened and FFF beams are considered. The FFF beam has greatly reduced fluence off axis, especially as field size increases, compared with the flattened beam profile; hence, less scatter is generated in the phantom reaching the central axis.
Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Dosimetry; Flattening filter free; Phantom scatter; Radiotherapy

Mesh:

Year:  2014        PMID: 25454113     DOI: 10.1016/j.meddos.2014.10.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  1 in total

1.  An Analytical Method to Calculate Phantom Scatter Factor for Photon Beam Accelerators.

Authors:  Mohammad Javad Tahmasebi Birgani; Nahid Chegeni; Mohammad Ali Behrooz; Marziyeh Bagheri; Amir Danyaei; Azin Shamsi
Journal:  Electron Physician       Date:  2017-01-25
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.