Literature DB >> 25447702

Determination of plasma pipecolic acid by an easy and rapid liquid chromatography-tandem mass spectrometry method.

Michela Semeraro1, Maurizio Muraca2, Giulio Catesini2, Rita Inglese2, Francesca Iacovone2, Gloria Maria Barraco3, Melania Manco3, Sara Boenzi4, Carlo Dionisi-Vici4, Cristiano Rizzo2.   

Abstract

Pipecolic acid (PA) is an important biochemical marker for the diagnosis of peroxisomal disorders. PA is also a factor responsible for hepatic encephalopathy and a possible biomarker for pyridoxine-dependent seizures. We developed an easy and rapid PA quantification method, by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), requiring no derivatization and applicable to small sample volumes. Plasma (100 μl) is extracted with 500 μl acetonitrile (ACN) containing 2 μmol/l [(2)H5]-phenylalanine as internal standard, vortexed and centrifuged. The supernatant is analyzed by HPLC-MS/MS in positive-ion mode using multiple reaction monitoring scan type. HPLC column is a Luna HILIC (150×3.0mm; 3 μ 200A): Buffer A: ammonium formate 5 mmol/l; Buffer B: ACN/H20 90:10 containing ammonium formate 5 mmol/l. PA retention time is 4.86 min. Recovery was 93.8%, linearity was assessed between 0.05 and 50 μmol/l (R(2)=0.998), lower limit of detection was 0.010 μmol/l and lower limit of quantification was 0.050 μmol/l. Coefficient of variation was 3.2% intra-assay and 3.4% inter-assay, respectively. Clinical validation was obtained by comparing PA plasma values from 5 patients affected by peroxisomal disorders (mean, 23.38 μmol/l; range, 11.20-37.1 μmol/l) to 24 ages related healthy subjects (mean, 1.711 μmol/l; range, 0.517-3.580 μmol/l).
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Hepatic encephalopathy; Liquid chromatography–tandem mass spectrometry; Peroxisomal disorders; Pipecolic acid; Pyridoxine-dependent seizures

Mesh:

Substances:

Year:  2014        PMID: 25447702     DOI: 10.1016/j.cca.2014.11.014

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  3 in total

1.  Biomarker Profiling for Pyridoxine Dependent Epilepsy in Dried Blood Spots by HILIC-ESI-MS.

Authors:  Elizabeth Mary Mathew; Sudheer Moorkoth; Leslie Lewis; Pragna Rao
Journal:  Int J Anal Chem       Date:  2018-08-01       Impact factor: 1.885

2.  Metabolic Profiling Identified a Novel Biomarker Panel for Metabolic Syndrome-Positive Hepatocellular Cancer.

Authors:  Lin-Lin Cao; Yi Han; Yuanxiao Wang; Lin Pei; Zhihong Yue; Li Qin; Boyu Liu; Jingwen Cui; Mei Jia; Hui Wang
Journal:  Front Endocrinol (Lausanne)       Date:  2022-01-26       Impact factor: 5.555

3.  Laboratory diagnosis of disorders of peroxisomal biogenesis and function: a technical standard of the American College of Medical Genetics and Genomics (ACMG).

Authors:  Irene De Biase; Silvia Tortorelli; Lisa Kratz; Steven J Steinberg; Kristina Cusmano-Ozog; Nancy Braverman
Journal:  Genet Med       Date:  2019-12-11       Impact factor: 8.822

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.