Literature DB >> 25443880

Effect of attachment types and number of implants supporting mandibular overdentures on stress distribution: a computed tomography-based 3D finite element analysis.

Selda Arat Bilhan1, Cengiz Baykasoglu2, Hakan Bilhan3, Omer Kutay4, Ata Mugan5.   

Abstract

The objective of this study was to calculate stresses in bone tissue surrounding uncoupled and splinted implants that are induced by a bite force applied to the mandible and to determine whether the number of mandibular overdenture supporting implants in mandibular bone influence the stress distribution. A human adult edentulous mandible retrieved from a formalin fixed cadaver was used to define the geometry of finite element (FE) model and the FE model was verified with experimental measurements. Following the FE model validation, three different biting situations were simulated for the 2-, 3- and 4-implant retentive anchor as well as bar attachment overdentures under vertical loading of 100 N. As a result of the analyses, it was concluded that an increment in implant number and the splinted attachment type tended to cause lower stresses and the use of two single attachments seems to be a safe and sufficient solution for the treatment of mandibular edentulism with overdentures.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Attachment type; Biomechanics; Finite element analysis; Mandibular overdenture; Number of implants; Stress distribution

Mesh:

Substances:

Year:  2014        PMID: 25443880     DOI: 10.1016/j.jbiomech.2014.10.022

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

Review 1.  To what extent residual alveolar ridge can be preserved by implant? A systematic review.

Authors:  Ahmed Khalifa Khalifa; Masahiro Wada; Kazunori Ikebe; Yoshinobu Maeda
Journal:  Int J Implant Dent       Date:  2016-11-23

Review 2.  Finite element analysis of dental implants with validation: to what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process.

Authors:  Yuanhan Chang; Abhijit Anil Tambe; Yoshinobu Maeda; Masahiro Wada; Tomoya Gonda
Journal:  Int J Implant Dent       Date:  2018-03-08

3.  Evaluation of stress distribution of porous tantalum and solid titanium implant-assisted overdenture in the mandible: A finite element study.

Authors:  Ayshin Akbarzadeh; Yasser Hemmati; Fariba Saleh-Saber
Journal:  Dent Res J (Isfahan)       Date:  2021-12-10

Review 4.  Peri-implant stress distribution assessment of various attachment systems for implant supported overdenture prosthesis by finite element analysis - A systematic review.

Authors:  Bappaditya Bhattacharjee; Ritu Saneja; Ankita Singh; Pavan Kumar Dubey; Atul Bhatnagar
Journal:  J Oral Biol Craniofac Res       Date:  2022-09-07

5.  Relationships of Stresses on Alveolar Bone and Abutment of Dental Implant from Various Bite Forces by Three-Dimensional Finite Element Analysis.

Authors:  Xiaoning Kang; Yiming Li; Yixi Wang; Yao Zhang; Dongsheng Yu; Yun Peng
Journal:  Biomed Res Int       Date:  2020-02-19       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.