Literature DB >> 25438308

Three-Dimensional Nonrigid MR-TRUS Registration Using Dual Optimization.

Yue Sun, Jing Yuan, Wu Qiu, Martin Rajchl, Cesare Romagnoli, Aaron Fenster.   

Abstract

In this study, we proposed an efficient nonrigid magnetic resonance (MR) to transrectal ultrasound (TRUS) deformable registration method in order to improve the accuracy of targeting suspicious regions during a three dimensional (3-D) TRUS guided prostate biopsy. The proposed deformable registration approach employs the multi-channel modality independent neighborhood descriptor (MIND) as the local similarity feature across the two modalities of MR and TRUS, and a novel and efficient duality-based convex optimization-based algorithmic scheme was introduced to extract the deformations and align the two MIND descriptors. The registration accuracy was evaluated using 20 patient images by calculating the TRE using manually identified corresponding intrinsic fiducials in the whole gland and peripheral zone. Additional performance metrics [Dice similarity coefficient (DSC), mean absolute surface distance (MAD), and maximum absolute surface distance (MAXD)] were also calculated by comparing the MR and TRUS manually segmented prostate surfaces in the registered images. Experimental results showed that the proposed method yielded an overall median TRE of 1.76 mm. The results obtained in terms of DSC showed an average of 80.8±7.8% for the apex of the prostate, 92.0±3.4% for the mid-gland, 81.7±6.4% for the base and 85.7±4.7% for the whole gland. The surface distance calculations showed an overall average of 1.84±0.52 mm for MAD and 6.90±2.07 mm for MAXD.

Entities:  

Mesh:

Year:  2014        PMID: 25438308     DOI: 10.1109/TMI.2014.2375207

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Deformable registration of trans-rectal ultrasound (TRUS) and magnetic resonance imaging (MRI) for focal prostate brachytherapy.

Authors:  Arnaldo Mayer; Adi Zholkover; Orith Portnoy; Gil Raviv; Eli Konen; Zvi Symon
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-26       Impact factor: 2.924

2.  Learning deep similarity metric for 3D MR-TRUS image registration.

Authors:  Grant Haskins; Jochen Kruecker; Uwe Kruger; Sheng Xu; Peter A Pinto; Brad J Wood; Pingkun Yan
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-10-31       Impact factor: 2.924

3.  Deformable registration of PET/CT and ultrasound for disease-targeted focal prostate brachytherapy.

Authors:  Sharmin Sultana; Daniel Y Song; Junghoon Lee
Journal:  J Med Imaging (Bellingham)       Date:  2019-09-12

4.  Multiparametric MRI-guided dose boost to dominant intraprostatic lesions in CT-based High-dose-rate prostate brachytherapy.

Authors:  Tonghe Wang; Robert H Press; Matt Giles; Ashesh B Jani; Peter Rossi; Yang Lei; Walter J Curran; Pretesh Patel; Tian Liu; Xiaofeng Yang
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

5.  Real-time multimodal image registration with partial intraoperative point-set data.

Authors:  Zachary M C Baum; Yipeng Hu; Dean C Barratt
Journal:  Med Image Anal       Date:  2021-09-21       Impact factor: 8.545

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.