Does Implant Design Affect Implant Primary Stability? A Resonance Frequency Analysis-Based Randomized Split-Mouth Clinical Trial.

Sergio Alexandre Gehrke1,2, Ulisses Tavares da Silva3, Massimo Del Fabbro4,5.   

Abstract

The purpose of this study was to assess implant stability in relation to implant design (conical vs. semiconical and wide-pitch vs narrow-pitch) using resonance frequency analysis. Twenty patients with bilateral edentulous maxillary premolar region were selected. In one hemiarch, conical implants with wide pitch (group 1) were installed; in the other hemiarch, semiconical implants with narrow pitch were installed (group 2). The implant allocation was randomized. The implant stability quotient (ISQ) was measured by resonance frequency analysis immediately following implant placement to assess primary stability (time 1) and at 90 days after placement (time 2). In group 1, the mean and standard deviation ISQ for time 1 was 65.8 ± 6.22 (95% confidence interval [CI], 55 to 80), and for time 2, it was 68.0 ± 5.52 (95% CI, 57 to 77). In group 2, the mean and standard deviation ISQ was 63.6 ± 5.95 (95% CI, 52 to 78) for time 1 and 67.0 ± 5.71 (95% CI, 58 to 78) for time 2. The statistical analysis demonstrated significant difference in the ISQ values between groups at time 1 (P = .007) and no statistical difference at time 2 (P = .54). The greater primary stability of conical implants with wide pitch compared with semiconical implants with narrow pitch might suggest a preference for the former in case of the adoption of immediate or early loading protocols.

Entities:  

Keywords:  dental implant; geometrical design; implant stability; resonance frequency analysis

Mesh:

Substances:

Year:  2014        PMID: 25438099     DOI: 10.1563/aaid-joi-D-13-00294

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  10 in total

1.  A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants: a preliminary study for simultaneous vertical ridge augmentation.

Authors:  Daisuke Ueno; Kei Nakamura; Kousuke Kojima; Takeshi Toyoshima; Hideaki Tanaka; Kazuhiko Ueda; Kiyoshi Koyano; Toshiro Kodama
Journal:  Odontology       Date:  2017-08-02       Impact factor: 2.634

2.  Evaluation of immediately loaded mandibular four vertical versus tilted posterior implants supporting fixed detachable restorations without versus with posterior cantilevers.

Authors:  Latifa Abdallah Mohamed; Mohamed Moataz Khamis; Ahlam Mostafa El-Sharkawy; Rania Abdelaziz Fahmy
Journal:  Oral Maxillofac Surg       Date:  2021-08-29

3.  Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis.

Authors:  Yashaswini Ellendula; Anam Chandra Sekar; Sandeep Nalla; Ram B Basany; Kunchala Sailasri; Ashwini Thandu
Journal:  Cureus       Date:  2022-04-29

4.  Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study.

Authors:  Hairong Huang; Daniel Wismeijer; Xianhong Shao; Gang Wu
Journal:  Ther Clin Risk Manag       Date:  2016-10-11       Impact factor: 2.423

5.  Implant Stability of Biological Hydroxyapatites Used in Dentistry.

Authors:  Maria Piedad Ramírez Fernández; Sergio A Gehrke; Patricia Mazón; Jose L Calvo-Guirado; Piedad N De Aza
Journal:  Materials (Basel)       Date:  2017-06-12       Impact factor: 3.623

6.  Multivariate linear regression analysis to identify general factors for quantitative predictions of implant stability quotient values.

Authors:  Hairong Huang; Zanzan Xu; Xianhong Shao; Daniel Wismeijer; Ping Sun; Jingxiao Wang; Gang Wu
Journal:  PLoS One       Date:  2017-10-30       Impact factor: 3.240

7.  Biomechanical Effects of a New Macrogeometry Design of Dental Implants: An In Vitro Experimental Analysis.

Authors:  Sergio Alexandre Gehrke; Leticia Pérez-Díaz; Patricia Mazón; Piedad N De Aza
Journal:  J Funct Biomater       Date:  2019-10-25

8.  Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles.

Authors:  Sergio Alexandre Gehrke; Jaime Aramburú Júnior; Tiago Luis Eirles Treichel; Tales Dias do Prado; Berenice Anina Dedavid; Piedad N de Aza
Journal:  Sci Rep       Date:  2022-01-11       Impact factor: 4.996

9.  Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size.

Authors:  Vasilena Ivanova; Ivan Chenchev; Stefan Zlatev; Eitan Mijiritsky
Journal:  Int J Environ Res Public Health       Date:  2021-06-30       Impact factor: 3.390

10.  Influence of short implants geometry on primary stability.

Authors:  J González-Serrano; P Molinero-Mourelle; B Pardal-Peláez; L-M Sáez-Alcaide; R Ortega; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2018-09-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.