Literature DB >> 25437906

Eye shape using partial coherence interferometry, autorefraction, and SD-OCT.

Christopher A Clark1, Ann E Elsner, Benjamin J Konynenbelt.   

Abstract

PURPOSE: Peripheral refraction and retinal shape may influence refractive development. Peripheral refraction has been shown to have a high degree of variability and can take considerable time to perform. Spectral domain optical coherence tomography (SD-OCT) and peripheral axial length measures may be more reliable, assuming that the retinal position is more important than the peripheral optics of the lens/cornea.
METHODS: Seventy-nine subjects' right eyes were imaged for this study (age range, 22 to 34 years; refractive error, -10 to +5.00). Thirty-degree SD-OCT (Spectralis, Heidelberg Engineering, Heidelberg, Germany) images were collected in a radial pattern along with peripheral refraction with an autorefractor (Shin-Nippon Autorefractor) and peripheral axial length measurements with partial coherence interferometry (IOLMaster, Zeiss). Statistics were performed using repeated-measures analysis of variance in SPSS (IBM, Armonk, NY), Bland-Altman analyses, and regression. All measures were converted to diopters to allow direct comparison.
RESULTS: Spectral domain OCT showed a retinal shape with an increased curvature for myopes compared with emmetropes/hyperopes. This retinal shape change became significant around 5 degrees. The SD-OCT analysis for retinal shape provides a resolution of 0.026 diopters, which is about 10 times more accurate than using autorefraction (AR) or clinical refractive techniques. Bland-Altman analyses suggest that retinal shape measured by SD-OCT and the partial coherence interferometry method were more consistent with one another than either was with AR.
CONCLUSIONS: With more accurate measures of retinal shape using SD-OCT, consistent differences between emmetropes/hyperopes and myopes were found nearer to the fovea than previously reported. Retinal shape may be influenced by central refractive error, and not merely peripheral optics. Partial coherence interferometry and SD-OCT appear to be more accurate than AR, which may be influenced by other factors such as fixation and accommodation. Autorefraction does measure the optics directly, which may be a strength of that method.

Entities:  

Mesh:

Year:  2015        PMID: 25437906      PMCID: PMC4516166          DOI: 10.1097/OPX.0000000000000453

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  38 in total

Review 1.  A review of peripheral refraction techniques.

Authors:  Cathleen Fedtke; Klaus Ehrmann; Brien A Holden
Journal:  Optom Vis Sci       Date:  2009-05       Impact factor: 1.973

2.  Spectral reflectance of the human ocular fundus.

Authors:  F C Delori; K P Pflibsen
Journal:  Appl Opt       Date:  1989-03-15       Impact factor: 1.980

3.  The discrepancy between retinoscopic and subjective measurements: Effect of age.

Authors:  M Millodot; D O'Leary
Journal:  Am J Optom Physiol Opt       Date:  1978-05

4.  [Determination of the real size of an object on the fundus of the living eye].

Authors:  H Littmann
Journal:  Klin Monbl Augenheilkd       Date:  1982-04       Impact factor: 0.700

5.  Effect of ametropia on peripheral refraction.

Authors:  M Millodot
Journal:  Am J Optom Physiol Opt       Date:  1981-09

6.  Regulation of the mechanical properties of tree shrew sclera by the visual environment.

Authors:  J T Siegwart; T T Norton
Journal:  Vision Res       Date:  1999-01       Impact factor: 1.886

7.  Influence of eye rotation on peripheral eye length measurement obtained with a partial coherence interferometry instrument.

Authors:  Pavan K Verkicharla; Marwan Suheimat; Edward A H Mallen; David A Atchison
Journal:  Ophthalmic Physiol Opt       Date:  2014-01       Impact factor: 3.117

8.  Properties of the feedback loops controlling eye growth and refractive state in the chicken.

Authors:  F Schaeffel; H C Howland
Journal:  Vision Res       Date:  1991       Impact factor: 1.886

9.  More irregular eye shape in low myopia than in emmetropia.

Authors:  Juan Tabernero; Frank Schaeffel
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-05-27       Impact factor: 4.799

10.  Refractive error, axial length, and relative peripheral refractive error before and after the onset of myopia.

Authors:  Donald O Mutti; John R Hayes; G Lynn Mitchell; Lisa A Jones; Melvin L Moeschberger; Susan A Cotter; Robert N Kleinstein; Ruth E Manny; J Daniel Twelker; Karla Zadnik
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-06       Impact factor: 4.799

View more
  5 in total

1.  Distribution differences of macular cones measured by AOSLO: Variation in slope from fovea to periphery more pronounced than differences in total cones.

Authors:  Ann E Elsner; Toco Y P Chui; Lei Feng; Hong Xin Song; Joel A Papay; Stephen A Burns
Journal:  Vision Res       Date:  2016-11-03       Impact factor: 1.886

Review 2.  [Secondary diseases in high myopia].

Authors:  F Ziemssen; W Lagrèze; B Voykov
Journal:  Ophthalmologe       Date:  2017-01       Impact factor: 1.059

3.  Within-eye and between-subject variability for reflectance of the retinal nerve fibre layer.

Authors:  Hin Cheung; William H Swanson; Brett J King
Journal:  Ophthalmic Physiol Opt       Date:  2022-08-01       Impact factor: 3.992

4.  Ultrawide field, distortion-corrected ocular shape estimation with MHz optical coherence tomography (OCT).

Authors:  Bingyao Tan; Ryan P McNabb; Feihui Zheng; Yin Ci Sim; Xinwen Yao; Jacqueline Chua; Marcus Ang; Quan V Hoang; Anthony N Kuo; Leopold Schmetterer
Journal:  Biomed Opt Express       Date:  2021-08-23       Impact factor: 3.732

5.  The role of peripheral ocular length and peripheral corneal radius of curvature in determining refractive error.

Authors:  Saleh H A Alhussain; Edward A H Mallen; Niall C Strang; Sven Jonuscheit
Journal:  J Optom       Date:  2021-04-18
  5 in total