Influence of eye rotation on peripheral eye length measurement obtained with a partial coherence interferometry instrument.

Pavan K Verkicharla1, Marwan Suheimat, Edward A H Mallen, David A Atchison.   

Abstract

PURPOSE: The eye rotation approach for measuring peripheral eye length leads to concern about whether the rotation influences results, such as through pressure exerted by eyelids or extra-ocular muscles. This study investigated whether this approach is valid.
METHODS: Peripheral eye lengths were measured with a Lenstar LS 900 biometer for eye rotation and no-eye rotation conditions (head rotation for horizontal meridian and instrument rotation for vertical meridian). Measurements were made for 23 healthy young adults along the horizontal visual field (± 30°) and, for a subset of eight participants along the vertical visual field (± 25°). To investigate the influence of the duration of eye rotation, for six participants measurements were made at 0, 60, 120, 180 and 210 s after eye rotation to ± 30° along horizontal and vertical visual fields.
RESULTS: Peripheral eye lengths were not significantly different for the conditions along the vertical meridian (F1,7 = 0.16, p = 0.71). The peripheral eye lengths for the conditions were significantly different along the horizontal meridian (F1,22 = 4.85, p = 0.04), although not at individual positions (p ≥ 0.10) and were not important. There were no apparent differences between the emmetropic and myopic groups. There was no significant change in eye length at any position after maintaining position for 210 s.
CONCLUSION: Eye rotation and no-eye rotation conditions were similar for measuring peripheral eye lengths along horizontal and vertical visual field meridians at ± 30° and ± 25°, respectively. Either condition can be used to estimate retinal shape from peripheral eye lengths.
© 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

Entities:  

Keywords:  Lenstar; eye rotation; partial coherence interferometry; peripheral eye lengths; retinal shape

Mesh:

Year:  2014        PMID: 24325437     DOI: 10.1111/opo.12095

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  3 in total

1.  Validation of a partial coherence interferometry method for estimating retinal shape.

Authors:  Pavan K Verkicharla; Marwan Suheimat; James M Pope; Farshid Sepehrband; Ankit Mathur; Katrina L Schmid; David A Atchison
Journal:  Biomed Opt Express       Date:  2015-08-05       Impact factor: 3.732

2.  Eye shape using partial coherence interferometry, autorefraction, and SD-OCT.

Authors:  Christopher A Clark; Ann E Elsner; Benjamin J Konynenbelt
Journal:  Optom Vis Sci       Date:  2015-01       Impact factor: 1.973

3.  Treatment zone decentration promotes retinal reshaping in Chinese myopic children wearing orthokeratology lenses.

Authors:  Xue Li; Yingying Huang; Jiali Zhang; Chenglu Ding; Yunyun Chen; Hao Chen; Jinhua Bao
Journal:  Ophthalmic Physiol Opt       Date:  2022-05-22       Impact factor: 3.992