Literature DB >> 25425994

Chest pain associated with moderator band pacing.

Anil K Goli, Karoly Kaszala, Mohammed N Osman, John Lucke, Roger Carrillo.   

Abstract

A 65-year-old man was evaluated for chronic chest pain that had been present for 8 years after placement of a dual-chamber implantable cardioverter-defibrillator to treat inducible ventricular tachycardia. Previous coronary angiography had revealed nonobstructive coronary artery disease and a left ventricular ejection fraction of 0.45 to 0.50, consistent with mild idiopathic nonischemic cardiomyopathy. Evaluation with chest radiography and transthoracic echocardiography showed the implantable cardioverter-defibrillator lead to be embedded within the right ventricle at the moderator band, which had mild calcification. Treatment included extraction of the dual-coil lead and placement of a new single-coil right ventricular lead at the mid septum. The patient had complete relief of symptoms after the procedure. This case shows that chest pain can be associated with the placement of a right ventricular implantable cardioverter-defibrillator lead in the moderator band and that symptomatic relief can occur after percutaneous lead extraction and the implantation of a new right ventricular lead to the mid septal region.

Entities:  

Keywords:  Electrodes, implanted; heart conduction system; moderator band, right ventricular; pacemaker lead extraction; pacemaker, artificial/adverse effects; percutaneous intervention

Mesh:

Year:  2014        PMID: 25425994      PMCID: PMC4189363          DOI: 10.14503/THIJ-13-3602

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  8 in total

1.  Intracardiac stimulation for complete heart block.

Authors:  H LAGERGREN; L JOHANSSON
Journal:  Acta Chir Scand       Date:  1963-06

2.  Morphology of moderator bands (septomarginal trabecula) in porcine heart ventricles.

Authors:  A S Gulyaeva; I M Roshchevskaya
Journal:  Anat Histol Embryol       Date:  2012-02-20       Impact factor: 1.114

3.  An intracardiac bipolar electrode for interim treatment of complete heart block.

Authors:  V PARSONNET; I R ZUCKER; L GILBERT; M MAXIM ASA
Journal:  Am J Cardiol       Date:  1962-08       Impact factor: 2.778

4.  Morphological and histochemical studies on the cardiac conduction system of the dog.

Authors:  T Hara
Journal:  Arch Histol Jpn       Date:  1967-06

5.  On nerves and nerve endings in the conducting system of the moderator band (septomarginal trabecula).

Authors:  F Bojsen-Moller; J Tranum-Jensen
Journal:  J Anat       Date:  1971-04       Impact factor: 2.610

6.  Incidence and predictors of cardiac perforation after permanent pacemaker placement.

Authors:  Srijoy Mahapatra; Kevin A Bybee; T Jared Bunch; Raul E Espinosa; Lawrence J Sinak; Michael D McGoon; David L Hayes
Journal:  Heart Rhythm       Date:  2005-09       Impact factor: 6.343

7.  How it happened: my recollection of early pacing.

Authors:  H Lagergren
Journal:  Pacing Clin Electrophysiol       Date:  1978-01       Impact factor: 1.976

8.  Permanent transvenous pacing in 1962.

Authors:  V Parsonnet
Journal:  Pacing Clin Electrophysiol       Date:  1978-04       Impact factor: 1.976

  8 in total
  1 in total

1.  His-bundle pacing to treat an unusual case of chest pain after pacemaker implant.

Authors:  Matteo Parollo; Giulio Zucchelli; Mario Giannotti Santoro; Valentina Barletta; Luca Paperini; Maria Grazia Bongiorni
Journal:  J Cardiol Cases       Date:  2021-11-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.