Literature DB >> 25425984

Use of a melody pulmonary valve in transcatheter valve-in-valve replacement for tricuspid valve bioprosthesis degeneration.

David M Filsoof, David F Snipelisky, Brian P Shapiro.   

Abstract

Bioprosthetic heart valves can degenerate and fail over time. Repeat surgery as a means of replacement increases morbidity and mortality rates, and some patients are not candidates for reoperation. A newer treatment, percutaneous transcatheter valve-in-valve implantation, might delay or substitute for invasive procedures. We present the case of a 51-year-old woman, a poor candidate for surgery who had prosthetic tricuspid valve degeneration and stenosis. We successfully performed valve-in-valve placement of a Melody(®) valve, using a procedure originally intended to treat pulmonary valve conduit obstruction or regurgitation. To our knowledge, this is among the first case reports to describe the use of the Melody pulmonary valve in transcatheter valve-in-valve replacement for prosthetic tricuspid stenosis that was otherwise not correctable. Additional data and longer follow-up periods are necessary to gain an understanding of ideal indications and selection of patients for the percutaneous transcatheter treatment of tricuspid valve stenosis.

Entities:  

Keywords:  Heart valve diseases/pathology; heart valve prosthesis implantation/instrumentation/methods/trends; surgical procedures, minimally invasive/methods; treatment outcome; tricuspid valve insufficiency; tricuspid valve stenosis/therapy

Mesh:

Year:  2014        PMID: 25425984      PMCID: PMC4189353          DOI: 10.14503/THIJ-13-3544

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  18 in total

1.  Implantation of a Melody valve in tricuspid position.

Authors:  F T Riede; I Dähnert
Journal:  Catheter Cardiovasc Interv       Date:  2012-03-14       Impact factor: 2.692

2.  Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bioprosthesis: the first valve in valve procedure using the Corevalve Revalving system.

Authors:  Peter Wenaweser; Lutz Buellesfeld; Ulrich Gerckens; Eberhard Grube
Journal:  Catheter Cardiovasc Interv       Date:  2007-11-01       Impact factor: 2.692

3.  Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation.

Authors:  Thomas Walther; Volkmar Falk; Todd Dewey; Jörg Kempfert; Fabian Emrich; Bettina Pfannmüller; Petra Bröske; Michael A Borger; Gerhard Schuler; Michael Mack; Friedrich W Mohr
Journal:  J Am Coll Cardiol       Date:  2007-06-18       Impact factor: 24.094

4.  Prosthetic heart valves: selection of the optimal prosthesis and long-term management.

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Circulation       Date:  2009-02-24       Impact factor: 29.690

5.  Minimally invasive off-pump valve-in-a-valve implantation: the atrial transcatheter approach for re-operative mitral valve replacement.

Authors:  Jörg Kempfert; Johannes M Blumenstein; Michael A Borger; Axel Linke; Sven Lehmann; Patrick Pritzwald-Stegmann; Michael W A Chu; Gerhard Schuler; Volkmar Falk; Friedrich Wilhelm Mohr; Thomas Walther
Journal:  Eur Heart J       Date:  2008-06-20       Impact factor: 29.983

6.  Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves.

Authors:  John G Webb; David A Wood; Jian Ye; Ronen Gurvitch; Jean-Bernard Masson; Josep Rodés-Cabau; Mark Osten; Eric Horlick; O Wendler; Eric Dumont; Ronald G Carere; Namal Wijesinghe; Fabian Nietlispach; Mark Johnson; Chrisopher R Thompson; Robert Moss; Jonathon Leipsic; Brad Munt; Samuel V Lichtenstein; Anson Cheung
Journal:  Circulation       Date:  2010-04-12       Impact factor: 29.690

7.  Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction.

Authors:  P Bonhoeffer; Y Boudjemline; Z Saliba; J Merckx; Y Aggoun; D Bonnet; P Acar; J Le Bidois; D Sidi; J Kachaner
Journal:  Lancet       Date:  2000-10-21       Impact factor: 79.321

8.  Tricuspid valve surgery: a thirty-year assessment of early and late outcome.

Authors:  Thomas Guenther; Christian Noebauer; Domenico Mazzitelli; Raymonde Busch; Peter Tassani-Prell; Ruediger Lange
Journal:  Eur J Cardiothorac Surg       Date:  2008-06-25       Impact factor: 4.191

9.  Early percutaneous valve failure within bioprosthetic tricuspid tissue valve replacements.

Authors:  James Bentham; Shakeel Qureshi; Andreas Eicken; John Gibbs; George Ballard; John Thomson
Journal:  Catheter Cardiovasc Interv       Date:  2013-03-14       Impact factor: 2.692

10.  Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the u.s. Clinical trial.

Authors:  Evan M Zahn; William E Hellenbrand; James E Lock; Doff B McElhinney
Journal:  J Am Coll Cardiol       Date:  2009-10-27       Impact factor: 24.094

View more
  2 in total

1.  Transcatheter Tricuspid Valve-in-Valve Replacement with an Edwards Sapien 3 Valve.

Authors:  Pranav Loyalka; Angelo Nascimbene; Benjamin Metz; Igor D Gregoric; Ajay Sundara Raman; Biswajit Kar
Journal:  Tex Heart Inst J       Date:  2017-06-01

2.  Transcatheter Tricuspid Valve-in-Valve Replacement Using a J-Valve System for a Failed Tricuspid Bioprosthesis.

Authors:  Mingkui Zhang; Hui Xue; Lifu Miao; Xiujie Tang; Yanbin Shao
Journal:  Case Rep Cardiol       Date:  2022-06-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.