First registry results from the newly approved ACURATE TA™ TAVI system†.

Jörg Kempfert1, David Holzhey2, Steffen Hofmann3, Evaldas Girdauskas4, Hendrik Treede5, Holger Schröfel6, Matthias Thielmann7, Thomas Walther8.   

Abstract

OBJECTIVES: The novel ACURATE TA™ transcatheter aortic valve (Symetis, Ecublens, Switzerland) is composed of a self-expanding nitinol stent covered by an anti-paravalvular leak skirt designed for transapical implantation. Since Conformite Europeenne (CE)-mark approval, the first 250 patients implanted with the newly approved device have been included in this post-market, multicentre registry.
METHODS: The registry was conducted at 17 sites in Germany, Italy, Switzerland and Argentina to treat 250 high-risk elderly patients. This all-comers population presented preoperatively with a mean aortic gradient of 43.2 ± 17.4 mmHg, mean age of 80.9 ± 6.3 years, mean society of thoracic surgeons risk score of 8.0 ± 5.9% and mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) I of 22.3 ± 12.7%. The majority of patients (93%) were in New York Heart Association (NYHA) class III/IV. All patients were treated within a multidisciplinary Heart Team.
RESULTS: The procedural success rate was 98% (n = 245) with two valve-in-valve procedures and three conversions to conventional surgery. The 30-day mortality rate was 6.8%. Postimplant echocardiography revealed a relevant paravalvular leak (moderate 2+) in 2.3% of patients, with all other patients demonstrating either none/trace or a 1+ leak. The 30-day stroke rate was 2.8% and the mean transvalvular gradient was 12.4 ± 5.8 mmHg. A new pacemaker implantation was required in 10.0% of patients and 85% of patients returning for the follow-up presented in NYHA class I/II.
CONCLUSIONS: The short-term result of the registry shows a safety and efficacy profile comparable, if not improved in some aspects, with previously approved transcatheter aortic valve implantation devices. These 'real-world' data highlight an excellent functional outcome, especially in regard to a low rate of relevant paravalvular leak.
© The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic valve implantation; Minimally invasive; Transapical

Mesh:

Year:  2014        PMID: 25425552     DOI: 10.1093/ejcts/ezu367

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  9 in total

1.  Transcatheter aortic valve replacement-state of the art and a glimpse to the future: 'the Tailored Approach'.

Authors:  Francesco Bedogni; Alessandro Frigiola; Marco Ranucci; Nedy Brambilla; Rocco Antonio Montone; Mauro Agnifili; Lorenzo Menicanti; Luca Testa
Journal:  Eur Heart J Suppl       Date:  2016-04-29       Impact factor: 1.803

Review 2.  Alternate Access for TAVI: Stay Clear of the Chest.

Authors:  Pavel Overtchouk; Thomas Modine
Journal:  Interv Cardiol       Date:  2018-09

Review 3.  Transcatheter heart valve for aortic valve implantation: republication of the article published in the Japanese Journal of Artificial Organs.

Authors:  Hideki Oshima
Journal:  J Artif Organs       Date:  2018-02-09       Impact factor: 1.731

4.  Mechanisms of Heart Block after Transcatheter Aortic Valve Replacement - Cardiac Anatomy, Clinical Predictors and Mechanical Factors that Contribute to Permanent Pacemaker Implantation.

Authors:  Mark Young Lee; Srinath Chilakamarri Yeshwant; Sreedivya Chava; Daniel Lawrence Lustgarten
Journal:  Arrhythm Electrophysiol Rev       Date:  2015-08

5.  Transapical aortic valve implantation using a Symetis Acurate self-expandable bioprosthesis: initial outcomes of 10 patients.

Authors:  Marcin Misterski; Mateusz Puślecki; Marek Grygier; Anna Olasińska-Wiśniewska; Maciej Lesiak; Aleksander Araszkiewicz; Barłomiej Perek; Aneta Choręziak; Jacek Lindner; Anna Komosa; Piotr Buczkowski; Marcin Ligowski; Sławomir Katarzyński; Marek Jemielity
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2017-04-27       Impact factor: 1.195

6.  Transcatheter aortic valve implantation using the ACURATE TA™ system: 1-year outcomes and comparison of 500 patients from the SAVI registries.

Authors:  Jochen Börgermann; David M Holzhey; Matthias Thielmann; Evaldas Girdauskas; Holger Schroefel; Steffen Hofmann; Hendrik Treede; Klaus Matschke; Michael Hilker; Justus T Strauch; Thierry Carrel; Thorsten Wahlers; Anno Diegeler; Jörg Kempfert; Thomas Walther
Journal:  Eur J Cardiothorac Surg       Date:  2017-05-01       Impact factor: 4.191

Review 7.  Transcatheter aortic valve implantation: a revolution in the therapy of elderly and high-risk patients with severe aortic stenosis.

Authors:  Teoman Kilic; Irem Yilmaz
Journal:  J Geriatr Cardiol       Date:  2017-03       Impact factor: 3.327

8.  Emergent Percutaneous Rotational Atherectomy to Bailout Surgical Transapical Aortic Valve Implantation: A Successful Case of Heart Team Turnaround.

Authors:  Tawfiq Choudhury; Shahrukh N Bakar; Bob Kiaii; Patrick Teefy
Journal:  Arq Bras Cardiol       Date:  2019-12       Impact factor: 2.000

Review 9.  Conduction disturbances after transcatheter aortic valve implantation procedures - predictors and management.

Authors:  Krzysztof Wilczek; Rafał Reguła; Kamil Bujak; Piotr Chodór; Michał Długaszek; Mariusz Gąsior
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-08-19       Impact factor: 1.426

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.