Ultrasensitive photoelectrochemical immunoassay for matrix metalloproteinase-2 detection based on CdS:Mn/CdTe cosensitized TiO2 nanotubes and signal amplification of SiO2@Ab2 conjugates.

Gao-Chao Fan1, Li Han, Hua Zhu, Jian-Rong Zhang, Jun-Jie Zhu.   

Abstract

An ultrasensitive photoelectrochemical sandwich immunoassay was developed to detect matrix metalloproteinase-2 (MMP-2, antigen, Ag) based on CdS:Mn/CdTe cosensitized TiO2 nanotubes (TiO2-NTs) and signal amplification of SiO2@Ab2 conjugates. Specifically, the TiO2-NTs electrode was first deposited with CdS:Mn by successive ionic layer adsorption and reaction technique and then further coated with CdTe quantum dots (QDs) via the layer-by-layer method, forming TiO2-NTs/CdS:Mn/CdTe cosensitized structure, which was employed as a matrix to immobilize capture MMP-2 antibodies (Ab1); whereas, SiO2 nanoparticles were coated with signal MMP-2 antibodies (Ab2) to form SiO2@Ab2 conjugates, which were used as signal amplification elements via the specific antibody-antigen immunoreaction between Ag and Ab2. The ultrahigh sensitivity of this immunoassay derived from the two major reasons as below. First, the TiO2-NTs/CdS:Mn/CdTe cosensitized structure could adequately absorb the light energy, dramatically promote electron transfer, and effectively inhibit the electron-hole recombination, resulting in significantly enhanced photocurrent intensity of the sensing electrode. However, in the presence of target Ag, the immobilized SiO2@Ab2 conjugates could evidently increase the steric hindrance of the sensing electrode and effectively depress the electron transfer, leading to obviously decreased photocurrent intensity. Accordingly, the well-designed photoelectrochemical immunoassay exhibited a low detection limit of 3.6 fg/mL and a wide linear range from 10 fg/mL to 500 pg/mL for target Ag detection. Meanwhile, it also presented good reproducibility, specificity, and stability and might open a new promising platform for the detection of other important biomarkers.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25420143     DOI: 10.1021/ac504027d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Photoelectrochemical immunoassay for human interleukin 6 based on the use of perovskite-type LaFeO3 nanoparticles on fluorine-doped tin oxide glass.

Authors:  Xing-Pei Liu; Xing-Li Xie; Yu-Ping Wei; Chang-Jie Mao; Jing-Shuai Chen; He-Lin Niu; Ji-Ming Song; Bao-Kang Jin
Journal:  Mikrochim Acta       Date:  2017-12-14       Impact factor: 5.833

2.  Interference-free photoelectrochemical immunoassays using carboxymethylated dextran-coated and gold-modified TiO2 nanotube arrays.

Authors:  Wanze Guo; Jinping Wang; Wenjuan Guo; Qing Kang; Feimeng Zhou
Journal:  Anal Bioanal Chem       Date:  2021-06-11       Impact factor: 4.142

3.  Characteristics of P-Type and N-Type Photoelectrochemical Biosensors: A Case Study for Esophageal Cancer Detection.

Authors:  Joseph-Hang Leung; Hong-Thai Nguyen; Shih-Wei Feng; Sofya B Artemkina; Vladimir E Fedorov; Shang-Chin Hsieh; Hsiang-Chen Wang
Journal:  Nanomaterials (Basel)       Date:  2021-04-21       Impact factor: 5.076

4.  Visible-light driven Photoelectrochemical Immunosensor Based on SnS2@mpg-C3N4 for Detection of Prostate Specific Antigen.

Authors:  Yifeng Zhang; Yixin Liu; Rongxia Li; Malik Saddam Khan; Picheng Gao; Yong Zhang; Qin Wei
Journal:  Sci Rep       Date:  2017-07-05       Impact factor: 4.379

Review 5.  Bioanalytical methods for circulating extracellular matrix-related proteins: new opportunities in cancer diagnosis.

Authors:  Ramón Lorenzo-Gómez; Rebeca Miranda-Castro; Noemí de-Los-Santos-Álvarez; María Jesús Lobo-Castañón
Journal:  Anal Bioanal Chem       Date:  2021-06-05       Impact factor: 4.142

6.  A competitive photoelectrochemical immunosensor based on a CdS-induced signal amplification strategy for the ultrasensitive detection of dexamethasone.

Authors:  Xueping Wang; Tao Yan; Yan Li; Yixin Liu; Bin Du; Hongmin Ma; Qin Wei
Journal:  Sci Rep       Date:  2015-12-09       Impact factor: 4.379

7.  Photoelectrochemical Immunosensor for Detection of Carcinoembryonic Antigen Based on 2D TiO2 Nanosheets and Carboxylated Graphitic Carbon Nitride.

Authors:  Huan Wang; Yaoguang Wang; Yong Zhang; Qi Wang; Xiang Ren; Dan Wu; Qin Wei
Journal:  Sci Rep       Date:  2016-06-06       Impact factor: 4.379

Review 8.  Electrochemical sensing of blood proteins for mild traumatic brain injury (mTBI) diagnostics and prognostics: towards a point-of-care application.

Authors:  Nadezda Pankratova; Milica Jović; Marc E Pfeifer
Journal:  RSC Adv       Date:  2021-05-12       Impact factor: 4.036