Literature DB >> 25414477

A comparative experimental investigation of torque capabilities induced by conventional and active, passive self-ligating brackets.

Eleni N Katsikogianni1, Susanne Reimann2, Anna Weber2, Jakob Karp3, Christoph Bourauel2.   

Abstract

INTRODUCTION: A proper selected bracket-archwire combination displays a determining factor in the efficacy of torque applied to a tooth at the final stages of an orthodontic treatment. The objective of the current study was to assess the torque capabilities of various bracket systems combined with diverse archwire materials and cross-sections.
METHODS: The study comprised of four different 0.018-inch slot orthodontic brackets: the passive and the active self-ligating 1. Swiss Nonligating Bracket (SNB) and 2. SPEED and the metallic and the plastic conventional ligating 3. Mini Mono and 4. Brilliant, respectively, and four different archwire types: stainless steel and Nitinol: 0.016×0.016 inch and 0.016×0.022 inch. A 20 degrees labial crown torque (+20 degrees) and then a 20 degrees palatal crown torque (-20 degrees) were applied gradually on the upper right central incisor. Maximum torquing moments and torque play were registered.
RESULTS: Highest torquing moments were expressed by combining SPEED® with 0.016×0.022 inch stainless steel archwire. Lowest moments, but highest torque loss were registered by inserting a 0.016×0.016 inch Nitinol archwire in conventional ligating brackets.
CONCLUSIONS: Active self-ligating system manifests the best torque effectiveness. An evident dependence of the torque expression is displayed both on the type of ligation and on the material of the archwire.
© The Author 2014. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25414477     DOI: 10.1093/ejo/cju067

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  5 in total

1.  Root resorption due to orthodontic treatment using self-ligating and conventional brackets : A cone-beam computed tomography study.

Authors:  Isil Aras; Idil Unal; Gencer Huniler; Aynur Aras
Journal:  J Orofac Orthop       Date:  2018-04-12       Impact factor: 1.938

2.  Buccolingual Inclination Effects of Self-Ligating and Conventional Premolar Brackets: A Cone Beam Computed Tomography Study.

Authors:  Sabahat Yazıcıoğlu; A Alper Öz; A Zeynep Öz; Nursel Arıcı; Mete Özer; Selim Arıcı
Journal:  Turk J Orthod       Date:  2020-05-22

Review 3.  Torque expression in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review.

Authors:  Yousef Al-Thomali; Roshan-Noor Mohamed; Sakeenabi Basha
Journal:  J Clin Exp Dent       Date:  2017-01-01

4.  Variability of slot size in orthodontic brackets.

Authors:  Clémentine Lefebvre; Hassan Saadaoui; Jean-Marc Olive; Stéphane Renaudin; Fabienne Jordana
Journal:  Clin Exp Dent Res       Date:  2019-07-11

5.  A Comparison of the Ligation Torque Expression of a Ribbonwise Bracket-Archwire Combination and a Conventional Combination: A Primary Study.

Authors:  Bin Lin; Feifei Jiang; Jie Chen; Jiaxing Liang
Journal:  Int J Clin Pract       Date:  2022-09-28       Impact factor: 3.149

  5 in total