Banu Şahin Yildiz1, Alparslan Şahin, Nazire Başkurt Aladağ, Gülgün Arslan, Hakan Kaptanoğullari, İbrahim Akın, Mustafa Yildiz.
Abstract
OBJECTIVE: The effects of acute hemodialysis session on pulse wave velocity are conflicting. The aim of the current study was to assess the acute effects of ultrafiltration on the aortic mechanical properties using carotid-femoral (aortic) pulse wave velocity and pulse propagation time.Entities:
Mesh:
Year: 2014 PMID: 25413228 PMCID: PMC5336841 DOI: 10.5152/akd.2014.5373
Source DB: PubMed Journal: Anatol J Cardiol ISSN: 2149-2263 Impact factor: 1.596
Antropometric and hemodynamic values in hemodialysis patient and healthy subjects
| Hemodialysis patient | Healthy subjects | ||
|---|---|---|---|
| Age, years | 39.8±15.4 | 36.5±9.7 | 0.36 |
| Weight, kg | 65.03±10.77 | 70.13±11.78 | 0.10 |
| Height, m | 165.73±9.78 | 165.51±7.03 | 0.92 |
| Waist circumference, cm | 84.26±7.97 | 87.82±10.23 | 0.15 |
| Hip circumference, cm | 95.15±5.51 | 97.24±5.51 | 0.16 |
| Systolic blood pressure, mm Hg | 141.34±20.66 | 113.62±12.09 | <0.001 |
| Diastolic blood pressure, mm Hg | 82.50±14.64 | 72.75±7.62 | 0.004 |
| Mean blood pressure, mm Hg | 101.84±16.33 | 86.03±7.33 | <0.001 |
| Pulse pressure, mm Hg | 58.84±9.62 | 40.17±10.64 | <0.001 |
| Heart rate, beat/min | 81.50±8.91 | 76.34±10.15 | 0.05 |
| Pulse wave velocity, m/s | 10.99±3.08 | 9.27±1.45 | 0.01 |
| Pulse propagation time, s | 57.22±12.67 | 66.96±8.93 | 0.002 |
Figure 1The results of pulse wave velocity differences between hemodialysis patients and healthy subjects
HP - hemodialysis patients; HS - healthy subjects; PWV - pulse wave velocity (m/s)
Changing parameters in pre- and post-dialysis period
| Pre-dialysis period | Post-dialysis period | ||
|---|---|---|---|
| Weight, kg | 65.03±10.77 | 63.15±10.93 | <0.001 |
| Systolic blood pressure, mm Hg | 141.34±20.66 | 122.50±14.64 | <0.001 |
| Diastolic blood pressure, mm Hg | 82.50±14.64 | 75.76±9.66 | 0.001 |
| Mean blood pressure, mm Hg | 101.84±16.33 | 90.88±10.72 | <0.001 |
| Pulse pressure, mm Hg | 58.84±9.62 | 47.11±8.26 | <0.001 |
| Heart rate, beat/min | 81.50±8.91 | 89.53±10.16 | <0.001 |
| Pulse wave velocity, m/s | 11.21±3.11 | 10.48±2.58 | 0.02 |
| Pulse propagation time, s | 55.61±11.80 | 58.97±12.36 | 0.04 |
Correlation between pulse wave velocity and anthropometric and hemodynamic parameters
| Pulse wave velocity (m/s) | r | |
|---|---|---|
| Age, years | <0.001 | 0.48 |
| Dialysis duration, month | 0.57 | 0.21 |
| Weight, kg | 0.16 | 0.18 |
| Height, m | 0.02 | 0.29 |
| Waist circumference, cm | 0.02 | 0.30 |
| Hip circumference, cm | 0.28 | 0.14 |
| Systolic blood pressure, mm Hg | 0.001 | 0.43 |
| Diastolic blood pressure, mm Hg | 0.008 | 0.35 |
| Mean blood pressure, mm Hg | 0.002 | 0.41 |
| Pulse pressure, mm Hg | 0.009 | 0.35 |
| Heart rate, beat/min | 0.01 | 0.33 |
| Pulse propagation time, s | <0.001 | -0.87 |