Literature DB >> 25413163

Dosimetric comparison of different treatment modalities for stereotactic radiosurgery of meningioma.

David Kaul1, Harun Badakhshi, Thierry Gevaert, Diana Pasemann, Volker Budach, Constantin Tuleasca, Constantin Tulaesca, Arne Gruen, Vikas Prasad, Marc Levivier, Markus Kufeld.   

Abstract

BACKGROUND: The objective of this study was to compare the three most prominent systems for stereotactic radiosurgery in terms of dosimetric characteristics: the Cyberknife system, the Gamma Knife Perfexion and the Novalis system.
METHODS: Ten patients treated for recurrent grade I meningioma after surgery using the Cyberknife system were identified; the Cyberknife contours were exported and comparative treatment plans were generated for the Novalis system and Gamma Knife Perfexion. Dosimetric values were compared with respect to coverage, conformity index (CI), gradient index (GI) and beam-on time (BOT).
RESULTS: All three systems showed comparable results in terms of coverage. The Gamma Knife and the Cyberknife system showed significantly higher levels of conformity than the Novalis system (Cyberknife vs Novalis, p = 0.002; Gamma Knife vs Novalis, p = 0.002). The Gamma Knife showed significantly steeper gradients compared with the Novalis and the Cyberknife system (Gamma Knife vs Novalis, p = 0.014; Gamma Knife vs Cyberknife, p = 0.002) and significantly longer beam-on times than the other two systems (BOT = 66 ± 21.3 min, Gamma Knife vs Novalis, p = 0.002; Gamma Knife vs Cyberknife, p = 0.002).
CONCLUSIONS: The multiple focal entry systems (Gamma Knife and Cyberknife) achieve higher conformity than the Novalis system. The Gamma Knife delivers the steepest dose gradient of all examined systems. However, the Gamma Knife is known to require long beam-on times, and despite worse dose gradients, LINAC-based systems (Novalis and Cyberknife) offer image verification at the time of treatment delivery.

Entities:  

Mesh:

Year:  2014        PMID: 25413163     DOI: 10.1007/s00701-014-2272-9

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  10 in total

1.  Authors' reply to "Dosimetric of intracranial stereotactic radiosurgery: only 'an exercise of style'".

Authors:  Harald Treuer; Moritz Hoevels; Klaus Luyken; Veerle Visser-Vandewalle; Jochen Wirths; Martin Kocher; Maximilian Ruge
Journal:  Strahlenther Onkol       Date:  2015-10       Impact factor: 3.621

2.  Adaptive fractionated stereotactic Gamma Knife radiotherapy of meningioma using integrated stereotactic cone-beam-CT and adaptive re-planning (a-gkFSRT).

Authors:  F Stieler; F Wenz; Y Abo-Madyan; B Schweizer; M Polednik; C Herskind; F A Giordano; S Mai
Journal:  Strahlenther Onkol       Date:  2016-07-05       Impact factor: 3.621

3.  Primary and Secondary Optic Nerve Sheath Meningioma.

Authors:  Elena Solli; Roger E Turbin
Journal:  J Neurol Surg B Skull Base       Date:  2021-02-18

4.  Comparison of Ray Tracing and Monte Carlo Calculation Algorithms for Spine Lesions Treated With CyberKnife.

Authors:  Jun Li; Xile Zhang; Yuxi Pan; Hongqing Zhuang; Ruijie Yang
Journal:  Front Oncol       Date:  2022-05-04       Impact factor: 5.738

5.  Radiosurgery with flattening-filter-free techniques in the treatment of brain metastases : Plan comparison and early clinical evaluation.

Authors:  J Rieber; E Tonndorf-Martini; O Schramm; B Rhein; S Stefanowicz; J Kappes; H Hoffmann; K Lindel; J Debus; S Rieken
Journal:  Strahlenther Onkol       Date:  2016-07-04       Impact factor: 3.621

6.  Dosimetric comparison of different treatment modalities for stereotactic radiotherapy.

Authors:  Shih-Ming Hsu; Yuan-Chun Lai; Chien-Chung Jeng; Chia-Ying Tseng
Journal:  Radiat Oncol       Date:  2017-09-16       Impact factor: 3.481

7.  Cyberknife Dosimetric Planning Using a Dose-Limiting Shell Method for Brain Metastases.

Authors:  Kyoung Jun Yoon; Byungchul Cho; Jung Won Kwak; Doheui Lee; Do Hoon Kwon; Seung Do Ahn; Sang-Wook Lee; Chang Jin Kim; Sung Woo Roh; Young Hyun Cho
Journal:  J Korean Neurosurg Soc       Date:  2018-10-30

8.  Glioblastoma Adjacent to Radiosurgically Treated Arteriovenous Malformation: A Case Report and Review of the Literature.

Authors:  Kent R Richter; Reed A Richter; Christoph Griessenauer; Edward A Monaco
Journal:  Cureus       Date:  2022-02-10

9.  Comparison of four techniques for spine stereotactic body radiotherapy: Dosimetric and efficiency analysis.

Authors:  Saif Aljabab; Balamurugan Vellayappan; Eric Vandervoort; Jamie Bahm; Robert Zohr; John Sinclair; Jean-Michel Caudrelier; Janos Szanto; Shawn Malone
Journal:  J Appl Clin Med Phys       Date:  2018-02-07       Impact factor: 2.102

10.  Normofractionated stereotactic radiotherapy versus CyberKnife-based hypofractionation in skull base meningioma: a German and Italian pooled cohort analysis.

Authors:  Conti Alfredo; Senger Carolin; Acker Güliz; Kluge Anne; Pontoriero Antonio; Cacciola Alberto; Pergolizzi Stefano; Germanò Antonino; Badakhshi Harun; Kufeld Markus; Meinert Franziska; Nguyen Phuong; Loebel Franziska; Vajkoczy Peter; Budach Volker; Kaul David
Journal:  Radiat Oncol       Date:  2019-11-12       Impact factor: 3.481

  10 in total