Literature DB >> 25404230

Leaflet tear in a Trifecta aortic bioprosthesis 34 months after implantation.

Miguel Piñón1, Darío Durán2, Pablo Pazos3, Gonzalo Pradas2.   

Abstract

Bioprosthetic valves are used in aortic valve replacement to avoid lifelong anticoagulation. Bovine pericardial valves have excellent haemodynamics and equivalent freedom from reoperation compared with a porcine bioprosthesis [ 1]. However, early failure (parastent post-cusp tear) can take place due to mechanical stress. We report an acute structural failure on a Trifecta pericardial valve (St Jude Medical, Inc.) explanted after 34 months from a 71-year old woman.
© The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic valve insufficiency; Bioprosthesis; Reoperation

Mesh:

Year:  2014        PMID: 25404230     DOI: 10.1093/icvts/ivu384

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  8 in total

Review 1.  Pure Cusp Tear of Trifecta Bioprosthesis 2 Years after Aortic Valve Replacement.

Authors:  Masaki Hamamoto; Taira Kobayashi; Masamichi Ozawa; Kosuke Yoshimura
Journal:  Ann Thorac Cardiovasc Surg       Date:  2016-12-14       Impact factor: 1.520

2.  Mid-term clinical and health-related quality of life outcomes for the Trifecta bioprosthesis.

Authors:  Biswarup Purkayastha; Md Wasim Khan; Atanu Saha; Debasis Das; Lalit Kapoor; Mrinalendu Das; Pradeep Narayan
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-04-27

3.  Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis.

Authors:  Tatsuto Wakami; Shigeki Koizumi; Tadaaki Koyama
Journal:  J Cardiothorac Surg       Date:  2022-07-08       Impact factor: 1.522

4.  Mid-term clinical and haemodynamic results after aortic valve replacement with the Trifecta bioprosthesis.

Authors:  Augustijn Mortelé; Alexander Dereu; Thierry Bové; Katrien François
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-08-11

5.  Early surgical aortic bioprosthesis failure caused by cusp tear: A word of caution.

Authors:  Thibault Schaeffer; Denis Berdajs; Oliver Reuthebuch
Journal:  Clin Case Rep       Date:  2020-11-28

6.  Modes of failure of Trifecta aortic valve prosthesis.

Authors:  Pietro Giorgio Malvindi; Hassan Kattach; Suvitesh Luthra; Sunil Ohri
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-07-09

7.  Structural valve deterioration of a pericardial bioprosthesis.

Authors:  Hassan Kattach; Clifford W Barlow; Sunil K Ohri
Journal:  JTCVS Open       Date:  2021-12-14

8.  St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry.

Authors:  Giovanni Mariscalco; Silvia Mariani; Samuele Bichi; Andrea Biondi; Andrea Blasio; Paolo Borsani; Fabrizio Corti; Benedetta De Chiara; Riccardo Gherli; Cristian Leva; Claudio Francesco Russo; Giordano Tasca; Paolo Vanelli; Ottavio Alfieri; Carlo Antona; Germano Di Credico; Giampiero Esposito; Amando Gamba; Luigi Martinelli; Lorenzo Menicanti; Giovanni Paolini; Cesare Beghi
Journal:  J Cardiothorac Surg       Date:  2015-11-20       Impact factor: 1.637