| Literature DB >> 25400506 |
Péter Sárkány1, Szabolcs Lengyel2, Réka Nemes1, Lívia Orosz1, Dénes Páll2, Csilla Molnár1, Béla Fülesdi1.
Abstract
BACKGROUND: Peritoneal insufflation results in hemodynamic changes during laparoscopic cholecystectomy. The aim of the present work is to test whether non-invasive applanation tonometry is suitable for reflecting these hemodynamic alterations.Entities:
Keywords: Applanation tonometry; Hemodynamic changes; Laparoscopic cholecystectomy
Mesh:
Substances:
Year: 2014 PMID: 25400506 PMCID: PMC4232719 DOI: 10.1186/1471-2253-14-98
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
The effect of anesthetic induction on peripheral and central (aortic) blood pressures, ejection duration and pressure augmentation
| Before induction | After induction | p-value | |
|---|---|---|---|
|
| |||
|
| 132.47 ± 18.87 | 116.80 ± 18.61 | P < 0.001 |
|
| 78.60 ± 10.40 | 72.71 ± 13.54 | 0.01 |
|
| 52.12 ± 16.12 | 43.65 ± 11.96 | P < 0.01 |
|
| |||
|
| 120.80 ± 19.10 | 106.77 ± 18.78 | P < 0.001 |
|
| 80.00 ± 10.38 | 73.88 ± 13.79 | P < 0.01 |
|
| 41.05 ± 14.70 | 33.11 ± 11.08 | P < 0.001 |
|
| 41.0 ± 4.93 | 38.40 ± 6.71 | 0.01 |
|
| |||
|
| 10.52 ± 8.52 | 7.31 ± 5.59 | P < 0.01 |
|
| 23.62 ± 10.58 | 18.97 ± 10.80 | P < 0.01 |
|
| 121.85 ± 22.7 | 142.5 ± 38.2 | P < 0.01 |
Means and standard deviations are shown.
The effect of peritoneal cavity insufflation on peripheral and central (aortic) blood pressures, ejection duration and pressure augmentation
| Before insufflation | After insufflation | p-value | |
|---|---|---|---|
|
| |||
|
| 116.80 ± 18.61 | 125.17 ± 20.21 | 0.02 |
|
| 72.71 ± 13.54 | 78.92 ± 16.94 | 0.07 |
|
| 43.65 ± 11.96 | 44.64 ± 13.23 | 0.24 |
|
| |||
|
| 106.77 ± 18.78 | 118.05 ± 19.85 | P < 0.01 |
|
| 73.88 ± 13.79 | 81.82 ± 12.28 | P < 0.01 |
|
| 33.11 ± 11.08 | 36.41 ± 12.60 | 0.04 |
|
| 38.40 ± 6.71 | 39.15 ± 5.51 | 0.34 |
|
| |||
|
| 7.31 ± 5,59 | 12.61 ± 7.56 | P < 0.001 |
|
| 18.97 ± 10.80 | 31.55 ± 12.01 | P < 0.001 |
|
| 142.5 ± 38.2 | 137.11 ± 26.3 | P = 0.48 |
Means and standard deviations are shown.
Comparison of peripheral and central (aortic) blood pressures, ejection duration and pressure augmentation values at phases before induction and after peritoneal insufflation
| Before induction | After insufflation | p-value | |
|---|---|---|---|
|
| |||
|
| 132.47 ± 18.87 | 125.17 ± 20.21 | 0.10 |
|
| 78.60 ± 10.40 | 78.92 ± 16.94 | 0.91 |
|
| 52.12 ± 16.12 | 44.64 ± 13.23 | 0.02 |
|
| |||
|
| 120.80 ± 19.10 | 118.05 ± 19.85 | 0.53 |
|
| 80.00 ± 10.38 | 81.82 ± 12.28 | 0.47 |
|
| 41.05 ± 14.70 | 36.41 ± 12.60 | 0.13 |
|
| 41.0 ± 4.93 | 39.15 ± 5.51 | 0.11 |
|
| |||
|
| 10.52 ± 8.52 | 12.61 ± 7.56 | 0.25 |
|
| 23.62 ± 10.58 | 31.55 ± 12.01 | <0.01 |
|
| 121.85 ± 22.7 | 137.11 ± 26.3 | <0.01 |
Means and standard deviations are shown.
Figure 1Changes of hemodynamic parameters during the study: Means and standard deviations are shown. ӿ ӿ indicate p < 0.01, ӿ ӿ ӿ indicate p < 0.001 compared to preinduction value; ‡ ‡ p < 0.01, ‡ ‡ indicate p < 0.001 statistical difference compared to preinsufflation value.