Literature DB >> 17714573

Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum.

F Bliacheriene1, S B Machado, E B Fonseca, D Otsuke, J O C Auler, F Michard.   

Abstract

BACKGROUND: Pulse pressure variation (DeltaPP) and systolic pressure variation (SPV) induced by mechanical ventilation have been proposed to detect hypovolaemia and guide fluid therapy. During laparoscopic surgery, chest compliance is decreased by pneumoperitoneum. This may affect the value of SPV and DeltaPP as indicators of intravascular volume status. Thereby, we investigated the effects of pneumoperitoneum and hypovolaemia on SPV and DeltaPP.
METHODS: We measured DeltaPP, SPV and the inspiratory (Deltaup) and expiratory (Deltadown) components of SPV, at baseline, during pneumoperitoneum, during pneumoperitoneum and hypovolaemia and after the return to baseline conditions, in 11 mechanically ventilated rabbits. Pneumoperitoneum was induced by inflating the abdomen with carbon dioxide, and hypovolaemia was induced by controlled haemorrhage.
RESULTS: Pneumoperitoneum induced an increase in SPV from 8.5 +/- 1.6 to 13.3 +/- 2.6 mmHg (+56%, P < 0.05) as a result of an increase in Deltaup from 2.0 +/- 1.0 to 6.7 +/- 2.1 mmHg (+236%, P < 0.05), but no significant change in Deltadown, nor in DeltaPP. Haemorrhage induced a significant (P < 0.05) increase in SPV from 13.3 +/- 2.6 to 19.9 +/- 3.7 mmHg (+50%), in Deltadown from 6.6 +/- 3.3 to 14.0 +/- 4.9 mmHg (+112%) and in DeltaPP from 11.1 +/- 4.8 to 24.9 +/- 9.8% (+124%) but no change in Deltaup. All parameters returned to baseline values after blood re-infusion and abdominal deflation.
CONCLUSIONS: SPV is modified by haemorrhage but it is also influenced by pneumoperitoneum. In contrast, DeltaPP is modified by haemorrhage but not by pneumoperitoneum. These findings suggest that DeltaPP should be used preferentially instead of SPV to detect hypovolaemia and guide fluid therapy during laparoscopic surgery.

Entities:  

Mesh:

Year:  2007        PMID: 17714573     DOI: 10.1111/j.1399-6576.2007.01432.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  11 in total

1.  Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose.

Authors:  Zhiyong He; Hui Qiao; Wei Zhou; Yun Wang; Zhendong Xu; Xuehua Che; Jun Zhang; Weimin Liang
Journal:  J Anesth       Date:  2011-09-21       Impact factor: 2.078

2.  Accuracy of pulse oximeter perfusion index in thoracic epidural anesthesia under basal general anesthesia.

Authors:  Zifeng Xu; Jianhai Zhang; Yunfei Xia; Xiaoming Deng
Journal:  Int J Clin Exp Med       Date:  2014-07-15

3.  Pneumoperitoneum affects stroke volume variation in humans.

Authors:  Zen'ichiro Wajima; Toshiya Shiga; Kazuyuki Imanaga
Journal:  J Anesth       Date:  2014-12-30       Impact factor: 2.078

4.  Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension.

Authors:  F Díaz; B Erranz; A Donoso; T Salomon; Pablo Cruces
Journal:  BMC Anesthesiol       Date:  2015-09-22       Impact factor: 2.217

5.  Non-invasive pulse wave analysis for monitoring the cardiovascular effects of CO2 pneumoperitoneum during laparoscopic cholecystectomy--a prospective case-series study.

Authors:  Péter Sárkány; Szabolcs Lengyel; Réka Nemes; Lívia Orosz; Dénes Páll; Csilla Molnár; Béla Fülesdi
Journal:  BMC Anesthesiol       Date:  2014-10-31       Impact factor: 2.217

6.  The correlation between the Trendelenburg position and the stroke volume variation.

Authors:  Jin Hye Min; Sang Eun Lee; Hong Sik Lee; Young Keun Chae; Yong Kyung Lee; Yoo Kang; Ui Jin Je
Journal:  Korean J Anesthesiol       Date:  2014-12-29

7.  Pulse pressure variation shows a direct linear correlation with tidal volume in anesthetized healthy patients.

Authors:  Yi Liu; Jing-Sheng Lou; Wei-Dong Mi; Wei-Xiu Yuan; Qiang Fu; Min Wang; Jing Qu
Journal:  BMC Anesthesiol       Date:  2016-09-08       Impact factor: 2.217

8.  The tidal volume challenge improves the reliability of dynamic preload indices during robot-assisted laparoscopic surgery in the Trendelenburg position with lung-protective ventilation.

Authors:  Joo-Hyun Jun; Rack Kyung Chung; Hee Jung Baik; Mi Hwa Chung; Joon-Sang Hyeon; Young-Goo Lee; Sung-Ho Park
Journal:  BMC Anesthesiol       Date:  2019-08-07       Impact factor: 2.217

9.  Perioperative risk factors for prolonged mechanical ventilation after liver transplantation due to acute liver failure.

Authors:  Serin Lee; Hyun Sik Jung; Jong Ho Choi; Jaemin Lee; Sang Hyun Hong; Sung Hyun Lee; Chul-Soo Park
Journal:  Korean J Anesthesiol       Date:  2013-09-25

10.  Effect of pneumoperitoneum on dynamic variables of fluid responsiveness (Delta PP and PVI) during Trendelenburg position.

Authors:  Djamal Ghoundiwal; Amelie Delaporte; Javad Bidgoli; Patrice Forget; Jean-François Fils; Philippe Van der Linden
Journal:  Saudi J Anaesth       Date:  2020-05-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.