| Literature DB >> 25394494 |
Marlo K Sellin Jeffries, Andor J Kiss, Austin W Smith, James T Oris.
Abstract
BACKGROUND: This study compared the performance of five commercially available kits in extracting total RNA from small eukaryotic tissue samples (<15 mg). Total RNA was isolated from fathead minnow (Pimephales promelas) tissues (spleen, blood, kidney, embryo, and larvae) using the Qiagen RNeasy® Plus Mini, Qiagen RNeasy® Plus Universal, Promega Maxwell® 16 LEV simplyRNA, Ambion MagMAX™-96 and Promega SimplyRNA HT kits. Kit performance was evaluated via measures of RNA quantity (e.g., total RNA amount) and quality (e.g., ratio of absorbance at 260 and 280 nm, RNA integrity number (RIN), presence of gDNA).Entities:
Mesh:
Substances:
Year: 2014 PMID: 25394494 PMCID: PMC4239376 DOI: 10.1186/s12896-014-0094-8
Source DB: PubMed Journal: BMC Biotechnol ISSN: 1472-6750 Impact factor: 2.563
Figure 1Visual description of the experimental design utilized to evaluate the performance of the Plus Mini, Plus Universal, Maxwell®, MagMAXTM and SimplyRNA HT RNA extraction kits.
Descriptions of the five commercial kits selected for inclusion in this study
|
|
|
|
|
|---|---|---|---|
| Qiagen RNeasy® Plus Mini (#74134) | Manual Operationa; Guanidine-isothiocyanate lysis, Silica membrane-based RNA purification, Non-enzymatic DNA elimination | Tissue Mass: ≤30 mg | $6.02 |
| Minimum Elution Volume: 30 μLc | |||
| Qiagen RNeasy® Plus Universal Mini (#73404) | Manual Operationa; Phenol-guanidine lysis, Silica membrane-based RNA purification, Non-enzymatic DNA elimination | Tissue Mass: ≤50 mg | $6.86 |
| Minimum Elution Volume: 30 μLc | |||
| Promega Maxwell® 16 LEV simplyRNA Purification (#AS1280) | Automated Operation; Guanidine-thiocyanate lysis, Paramagnetic bead-based RNA purification, Enzymatic DNA elimination | Tissue Mass: ≤50 mg | $5.25 |
| Minimum Elution Volume: 30 μLc | |||
| Ambion MagMAX™-96 Total RNA Isolation (#AM1830) | Automated Operationb; Guanidinium thiocyanate-based lysis, Magnetic bead-based RNA purification, Enzymatic DNA elimination | Tissue Mass: ≤5 mg | $3.19 |
| Minimum Elution Volume: 20 μL | |||
| Promega SimplyRNA HT System (Beta test kite) | Automated Operation; Guanidine-thiocyanate lysis, Paramagnetic bead-based RNA purification, Enzymatic DNA elimination | Tissue Mass: 5–300 mg | $3.50-5.25 |
| Minimum Elution Volume: 30 μL |
aThis kit can be automated on the Qiagen QIAcube robotic workstation.
bThis kit can be used manually.
cFor the Plus Mini, Plus Universal and Maxwell® kits, an elution volume of 30 μL was used for RNA extracted from blood, embryos and larvae, while an elution volume of 50 μL was used for RNA isolated from spleens and kidneys. Elution volumes for all tissues extracted via the MagMAX™ and SimplyRNA HT kits were 55 and 50 μL, respectively.
dList price in June 2013; Prices are for the kits only and do not include the costs of equipment and reagents not supplied with the kit.
eBeta test kit of a new 96-well format high throughput, RNA purification system. Final specifications in development.
The average (± standard deviation) masses of tissues subject to RNA extractions via each kit
|
|
|
|
|
| |
|---|---|---|---|---|---|
| Plus Mini | 19.5 (4.0) | 5.3 (2.9) | 20.3 (8.0) | 1.1 (0.04) | 6.4 (0.6) |
| Plus Universal | 14.8 (2.8) | 3.5 (1.2) | 14.0 (4.6) | 1.1 (0.1) | 5.9 (0.8) |
| Maxwell® | 20.0 (7.6) | 3.7 (1.7) | 13.4 (6.2) | 1.1 (0.03) | 6.7 (1.1) |
| MagMAX™ | 4.0 (0.7)a | 1.7 (0.9) | 3.8 (1.8)a | 1.1 (0.1) | 6.5 (0.5) |
| SimplyRNA HT | 11.3 (3.8) | 4.9 (3.4) | 14.3 (7.9) | 1.2 (0.1) | 5.3 (1.9) |
aTissues processed using the MagMAX™ kit were trimmed to achieve manufacturer suggested tissues masses ≤5 mg.
The minimum quantity and quality criteria for RNA used to evaluate the suitability of RNA extracted via each kit for analysis via real-time quantitative (qPCR), microarray or next generation sequencing (NGS) technologies
|
|
|
| |
|---|---|---|---|
| qPCR | ≥ 1 μg | ≥ 1.8 | ≥ 5 |
| Microarray | ≥ 5 μg | ≥ 1.8 | ≥ 7 |
| NGS | ≥ 1 μg | ≥ 1.8 | ≥ 7 |
Figure 2The quantity of RNA extracted from fathead minnow tissues using five commercially available RNA extraction kits. The RNA amounts shown in panels on the left (A, C, E, G and I) reflect the total amount of RNA recovered (ng), while the RNA amounts reported in panels on the right (B, D, F, H and J) indicate the amount (ng) of RNA recovered per mass (mg) of tissue. The reported p-values were obtained by one-way ANOVA, except for those denoted by a “W”. The “W” indicates that significant differences in variance were detected and that analysis was conducted via a Welch ANOVA. Error bars indicate standard deviation. Different letters above bars indicate significant differences in the measured RNA quantity parameter between samples processed by each of the kits. Percentages reported in each bar are indicative of the coefficient of variance.
Figure 3The quality of RNA extracted from fathead minnow tissues using five commercially available RNA isolation kits. The panels on the left (A, C, E, G and I) show the 260/280 ratios of RNA extracted using each kit; the dashed lines on each panel represents a 260/280 ratio of 1.8 (the value above which RNA is considered to be “pure”). The panels on the right (B, D, F, H and J) show the RNA integrity number (RIN); the dashed line represents a RIN of 5 (the minimum acceptable RIN for qPCR analysis), while the dotted line shows a RIN of 7 (the minimum recommended RIN for microarray and next generation sequencing analyses). Reported p-values were obtained by one-way ANOVA, except for those denoted by a “W”. The “W” indicates that significant differences in variance were detected and that analysis was conducted via a Welch ANOVA. Error bars indicate standard deviation. Different letters above bars indicate significant differences in the measured RNA quantity parameter between samples processed by each of the kits. Percentages reported in each bar are indicative of the coefficient of variance. RIN values were not measurable (indicated by “nm”) in RNA extracted from embryos using the SimplyRNA HT kit due to low RNA concentrations.
Figure 4A representative example of the gel images produced during RNA quality checks performed via the Bioanalyzer 2100. The composite gel image was generated from the results of RNA quality assessments performed on RNA extracted from larvae samples. For each kit, the lane corresponding to the sample that best represented the “average” RNA yielded is included. The first number reported for each kit represents the RIN value of the sample shown, while the numbers below represent the mean RIN value (± standard deviation) for all larvae samples extracted via each kit. Note that the lanes shown in the image were not obtained from samples run on the same Nanochip resulting in the misalignment of the 18S and 28S bands between some of the lanes.
Ability of each kit to effectively remove DNA from small tissue samples
|
|
| |||||
|---|---|---|---|---|---|---|
|
|
|
|
|
|
| |
|
| ||||||
| Blood | 33.65 | 31.71 | 1.94 | > 40* | 32.23 | 7.77† |
| Spleen | 39.84* | 28.62 | 11.22† | 39.84* | 29.59 | 10.25† |
| Kidney | 38.06* | 19.35 | 18.71† | > 40* | 23.41 | 16.59† |
| Embryo | > 40* | 27.82 | 12.18† | > 40* | 29.46 | 10.54† |
| Larvae | > 40* | 26.26 | 13.74† | > 40* | 27.86 | 12.14† |
|
| ||||||
| Blood | 33.27 | 32.87 | 0.40 | > 40* | 34.07 | 5.93† |
| Spleen | 34.77 | 28.90 | 5.87† | 39.92* | 29.14 | 10.78† |
| Kidney | 36.50* | 21.54 | 14.96† | > 40* | 22.18 | 17.82† |
| Embryo | 39.79* | 29.23 | 10.56† | > 40* | 31.17 | 8.83† |
| Larvae | > 40* | 20.74 | 19.26† | > 40* | 28.79 | 11.21† |
|
| ||||||
| Blood | > 40* | 34.19 | 5.81† | > 40* | 34.84 | 5.16† |
| Spleen | > 40* | 29.38 | 10.62† | > 40* | 30.25 | 9.75† |
| Kidney | > 40* | 20.52 | 19.48† | > 40* | 20.67 | 19.33† |
| Embryo | 37.09* | 26.41 | 10.68† | > 40* | 25.86 | 14.14† |
| Larvae | > 40* | 26.46 | 13.54† | > 40* | 27.55 | 12.45† |
|
| ||||||
| Blood | 29.79 | 28.11 | 1.68 | 39.02* | 32.65 | 6.37† |
| Spleen | > 40* | 29.93 | 10.07† | 38.04* | 30.36 | 7.68† |
| Kidney | 31.83 | 21.89 | 9.94† | 39.74* | 21.51 | 18.23† |
| Embryo | 36.34* | 22.57 | 13.77† | > 40* | 22.31 | 17.69† |
| Larvae | 33.75 | 27.54 | 6.21† | > 40* | 28.17 | 11.83† |
|
| ||||||
| Blood | > 40* | 31.06 | 8.94† | > 40* | 31.55 | 8.45† |
| Spleen | > 40* | 28.11 | 11.89† | > 40* | 27.9 | 12.10† |
| Kidney | > 40* | 21.54 | 18.46† | > 40* | 21.94 | 18.06† |
| Embryoa | - | - | - | - | - | - |
| Larvae | > 40* | 26.22 | 13.78† | > 40* | 26.00 | 14.00† |
The threshold cycle (Ct) values of samples subjected to the kit DNase treatment only (pre-DNase) or to an additional DNase treatment, as well as the corresponding “no RT” samples (see Methods for details). *represents no RT samples with Ct values ≥35 and thus, considered gDNA free. †indicates samples for which difference between the Ct values of the no RT and RT samples was ≥5, an indicator of sufficient gDNA removal for qPCR gene expression analysis.
aThe quantities of RNA isolated from embryos using the SimplyRNA HT kit were less than the amount necessary for the first-strand synthesis protocol used in this study; therefore, qPCR reactions could not be performed with these samples.