Literature DB >> 25382946

Subjective image quality comparison between two digital dental radiographic systems and conventional dental film.

Muhammed Ajmal1, Mohamed I Elshinawy2.   

Abstract

OBJECTIVES: Digital radiography has become an integral part of dentistry. Digital radiography does not require film or dark rooms, reduces X-ray doses, and instantly generates images. The aim of our study was to compare the subjective image quality of two digital dental radiographic systems with conventional dental film. MATERIALS &
METHODS: A direct digital (DD) 'Digital' system by Sirona, a semi-direct (SD) digital system by Vista-scan, and Kodak 'E' speed dental X-ray films were selected for the study. Endodontically-treated extracted teeth (n = 25) were used in the study. Details of enamel, dentin, dentino-enamel junction, root canal filling (gutta percha), and simulated apical pathology were investigated with the three radiographic systems. The data were subjected to statistical analyzes to reveal differences in subjective image quality.
RESULTS: Conventional dental X-ray film was superior to the digital systems. For digital systems, DD imaging was superior to SD imaging.
CONCLUSION: Conventional film yielded superior image quality that was statistically significant in almost all aspects of comparison. Conventional film was followed in image quality by DD, and SD provided the lowest quality images. Conventional film is still considered the gold standard to diagnose diseases affecting the jawbone. RECOMMENDATIONS: Improved software and hardware for digital imaging systems are now available and these improvements may now yield images that are comparable in quality to conventional film. However, we recommend that studies still use more observers and other statistical methods to produce ideal results.

Keywords:  Comparative radiographic study; Digital radiography; Direct digital imaging; Oral radiology; Semi-direct digital radiography

Year:  2014        PMID: 25382946      PMCID: PMC4223860          DOI: 10.1016/j.sdentj.2014.05.007

Source DB:  PubMed          Journal:  Saudi Dent J        ISSN: 1013-9052


  10 in total

1.  An introduction to digital radiography in dentistry.

Authors:  J Brennan
Journal:  J Orthod       Date:  2002-03

2.  Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems.

Authors:  K Syriopoulos; G C Sanderink; X L Velders; P F van der Stelt
Journal:  Dentomaxillofac Radiol       Date:  2000-09       Impact factor: 2.419

3.  Quality of film-based and digital panoramic radiography.

Authors:  B Molander; H-G Gröndahl; A Ekestubbe
Journal:  Dentomaxillofac Radiol       Date:  2004-01       Impact factor: 2.419

4.  An ex vivo comparison of conventional and digital radiography for perceived image quality of root fillings.

Authors:  B G Akdeniz; E Soğur
Journal:  Int Endod J       Date:  2005-06       Impact factor: 5.264

5.  Subjective image quality of digitally filtered radiographs acquired by the Dürr Vistascan system compared with conventional radiographs.

Authors:  S Yalcinkaya; A Künzel; R Willers; M Thoms; J Becker
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-01-19

6.  The use of dental radiographs: update and recommendations.

Authors: 
Journal:  J Am Dent Assoc       Date:  2006-09       Impact factor: 3.634

7.  A comparative study of image quality and radiation exposure for dental radiographs produced using a charge-coupled device and a phosphor plate system.

Authors:  S L Farrier; N A Drage; R G Newcombe; S J Hayes; P M H Dummer
Journal:  Int Endod J       Date:  2009-06-22       Impact factor: 5.264

Review 8.  Digital radiography and caries diagnosis.

Authors:  A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  1998-01       Impact factor: 2.419

Review 9.  Direct digital radiography in the dental office.

Authors:  A Wenzel; H G Gröndahl
Journal:  Int Dent J       Date:  1995-02       Impact factor: 2.512

10.  Digital radiology. Facts and fictions.

Authors:  S M Dunn; M L Kantor
Journal:  J Am Dent Assoc       Date:  1993-12       Impact factor: 3.634

  10 in total
  1 in total

1.  Analysis of photostimulable phosphor image plate artifacts and their prevalence.

Authors:  Sara Mohamed Elkhateeb; Ashwag Yagoub Aloyouny; Mohamed Mohamed Saeed Omer; Soad Mahmoud Mansour
Journal:  World J Clin Cases       Date:  2022-01-14       Impact factor: 1.337

  1 in total