Literature DB >> 25372785

Multimodal retinal vessel analysis in CADASIL patients.

Florian Alten1, Jeremias Motte2, Carina Ewering2, Nani Osada3, Christoph R Clemens1, Ella M Kadas4, Nicole Eter1, Friedemann Paul5, Martin Marziniak2.   

Abstract

PURPOSE: To further elucidate retinal findings and retinal vessel changes in Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) patients by means of high resolution retinal imaging.
METHODS: 28 eyes of fourteen CADASIL patients and an equal number of control subjects underwent confocal scanning laser ophthalmoscopy (cSLO), spectral-domain optical coherence tomography (SD-OCT), retinal nerve fibre layer (RNFL) measurements, fluorescein and indocyanine angiography. Three vessel measurement techniques were applied: RNFL thickness, a semiautomatic software tool based on cSLO images and manual vessel outlining based on SD-OCT.
RESULTS: Mean age of patients was 56.2 ± 11.6 years. Arteriovenous nicking was present in 22 (78.6%) eyes and venous dilation in 24 (85.7%) eyes. Retinal volume and choroidal volume were 8.77 ± 0.46 mm(3) and 8.83 ± 2.24 mm(3). RNFL measurements showed a global increase of 105.2 µm ( CONTROL GROUP: 98.4 µm; p = 0.015). Based on semi-automatic cSLO measurements, maximum diameters of arteries and veins were 102.5 µm (106.0 µm; p = 0.21) and 128.6 µm (124.4 µm; p = 0.27) respectively. Manual SD-OCT measurements revealed significantly increased mean arterial 138.7 µm (125.4 µm; p<0.001) and venous 160.0 µm (146.9; p = 0.003) outer diameters as well as mean arterial 27.4 µm (19.2 µm; p<0.001) and venous 18.3 µm (15.7 µm; p<0.001) wall thicknesses in CADASIL patients.
CONCLUSIONS: The findings reflect current knowledge on pathophysiologic changes in vessel morphology in CADASIL patients. SD-OCT may serve as a complementary tool to diagnose and follow-up patients suffering from cerebral small-vessel diseases.

Entities:  

Mesh:

Year:  2014        PMID: 25372785      PMCID: PMC4221286          DOI: 10.1371/journal.pone.0112311

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is a hereditary vascular small-vessel disease caused by Notch3 mutations [1]. It is distinguished from similar vascular disorders by the unique accumulation of granular osmiophilic material in systemic and particularly brain vasculature [2]. CADASIL represents a genetic model for small vessel diseases without the confounding factors of advanced age and other vascular diseases such as diabetes mellitus or arteriosclerosis. Besides migraine, transient ischemic attacks and strokes leading to severe disability and dementia in adult midlife in the absence of common vascular risk factors, CADASIL is clinically also characterized by various ophthalmologic findings [3]–[11]. Knowledge on the pathophysiology of CADASIL mainly derives from post mortem data due to the challenge of inspecting brain microvessels in vivo. Immunohistochemistry and electron microscopy have been proposed as useful diagnostic tools for CADASIL patients, yet, diagnostic sensitivity is still discussed controversially [12]–[14]. Architecture and properties of retinal blood vessels can provide essential clinical information not only in ocular disease but also in systemic disorders. Given the strong need for improved biomarkers in systemic vascular diseases, in-vivo imaging of retinal vessels appears to be a promising diagnostic approach. Recent technologic advances in imaging resolution and acquisition speed of commercial spectral-domain optical coherence tomography (SD-OCT) and confocal scanning laser ophthalmoscopy (cSLO) allow analysis of retinal morphology and retinal vessel morphology in greater detail and have contributed to our understanding of various retinal diseases. SD-OCT scans provide an ‘in-vivo histologic’ view and allow the differentiation of the various retinal layers as well as morphologic changes within these layers. Recently, high resolution SD-OCT proved to be capable of reliably measuring retinal vessel diameters and vessel wall thickness in vivo [15]–[17]. As CADASIL represents a model for small vessel diseases, this pathology is particularly suitable for research on vessel imaging. This study aims to evaluate three methods of retinal vessel analysis as well as to re-evaluate and to further elucidate retinal findings and retinal vessel changes in CADASIL patients using high resolution retinal imaging technology.

Methods

Demographics

Fourteen participants were recruited from the Department of Neurology at University of Muenster Medical Center. Diagnosis of CADASIL was confirmed in 12 patients by detection of Notch3 gene mutations and in two patients by vessel biopsy. Personal medical history was collected for each patient. Clinical investigations have been conducted according to the principles expressed in the Declaration of Helsinki. Informed consent, written and oral, have been obtained from the participants. The institutional review board of the ethics committee of the University of Berlin, Charité, approved the study. All patients went through a test battery containing the Montreal Cognitive Assessment (MoCA), a questionnaire for migraine and vascular risk factors. The cut-off for a cognitive impairment was <26 points in the MoCA. The MoCA offers a high sensitivity for mild cognitive impairment (MCI) and therefore, it is well suited to detect early stages of dementia in CADASIL patients [18]. Common risk factors and co-morbidities for vascular diseases (smoking, hypertension, diabetes mellitus, overweight, coronary heart disease, arterial obstructive disease and stroke) were recorded. Furthermore, a detailed medical history for migraine was taken. A staging regarding the course of disease based on the classification by Verin et al. was performed [19]. Every patient was assigned to stage I through IV. Stage I includes common migraine episodes, abnormal MRI as well as a reliable diagnosis of CADASIL. Stage II includes psychiatric abnormality, transient ischemic attack while stage III requires history of stroke and dementia. Patients of stage IV show a progressed disease with severe dementia and frequent strokes. All patients underwent a complete ophthalmic evaluation, including assessment of best-corrected visual acuity (BCVA), tonometry, slit-lamp biomicroscopy and fundus ophthalmoscopy. The visual field (VF) was defined by standard automated perimetry using a 30-2 central threshold test (Humphrey 740i, Zeiss Meditec, Germany). Heidelberg retina tomography (HRT, Heidelberg Engineering, Germany) was performed to rule out any glaucomatous damage. Age-matched healthy control subjects were attributed to CADASIL patients and underwent a complete ophthalmic evaluation as well.

Imaging protocol

Color fundus photography (CFP) was performed according to standard 7-field-method (Visucam, Carl Zeiss Meditech, Germany). cSLO near infrared (IR) imaging (λ = 820 nm; Spectralis; Heidelberg Engineering, Germany) was performed with a minimum resolution of 768×768 pixels. The field of view was set at 30°×30° and centered on the macula as well as on the optic disc. Scans were saved for evaluation after 100 frames had been averaged using the automatic averaging and eye-tracking feature of the Spectralis device. Imaging of the choroid was performed using enhanced depth imaging (EDI) OCT and indocyanine green angiography (ICG). EDI-OCT is a new approach to improve depth imaging and proved to be able to reliably image the full thickness of the choroid [20]. EDI-OCT volume scans were obtained consisting of 49 scans centered on the fovea. As previously described by Tanabe and colleagues, in each EDI-OCT scan, the cursor line marking the internal limiting membrane was moved manually to the outer border of the retinal pigment epithelium (RPE) [21]. Choroidal volume (CV) values in the posterior pole were obtained using the circular grid of the Early Treatment Diabetic Retinopathy Study (ETDRS) which is an integrated feature of the Heidelberg Eye Explorer software. This technique of manual CV measurements proved to be highly reproducible and repeatable and has a very small range of variability [22]. According to recorded EDI-OCT scans, additional SD-OCT volume scans were obtained to assess macular retinal volume (RV) within the ETDRS grid. ICG allows for clearly displaying choroidal circulation and for identifying and delineating of choroidal watershed zones (CWZ) [23]. ICG was performed using 5 mg ICG dye (ICG-Pulsion, Pulsion Medical Systems, Germany) diluted in 5 ml aqueous solvent, injected into a peripheral vein in the arm. The field of view was set at 30° and centered on fovea. Recordings were performed according to the 7-field method. Excitation wavelength was at 787 nm and the range of transmitted light through the barrier filter was above 800 nm (Spectralis; Heidelberg Engineering, Germany). ICG of CADASIL patients were evaluated for the presence of CWZ as well as any other angiographic findings. Fluorescence angiography (FA) was performed in the same manner using an injection of 3 ml fluorescein (Fluorescein, Alcon, Germany). Excitation wavelength was at 488 nm and the range of transmitted light through the barrier filter was 500–700 nm (Spectralis; Heidelberg Engineering, Germany).

Retinal nerve fiber layer measurements in SD-OCT

Measurement of retinal nerve fiber layer (RNFL) thickness was performed using a circular B-scan placed around the optic disc (diameter: 3.5 mm) [24]. The exactly located placement around the center of the optic disc was carefully reviewed. Sectorial analysis of mean RNFL thickness is illustrated in Figure 1.
Figure 1

A–D Measurement of retinal nerve fiber layer (RNFL) thickness, using a circular B-scan placed around the optic disc.

A Confocal scanning laser ophthalmoscopy infrared image shows optic disc with circular scan (diameter: 3.5 mm). B Corresponding spectral domain optical coherence tomography scan. Red marks delineate automatically borders of RNFL layer. C Presentation of RNFL thickness values for individual sectors and global measurement. D Individual measurement graphically compared to a healthy population.

A–D Measurement of retinal nerve fiber layer (RNFL) thickness, using a circular B-scan placed around the optic disc.

A Confocal scanning laser ophthalmoscopy infrared image shows optic disc with circular scan (diameter: 3.5 mm). B Corresponding spectral domain optical coherence tomography scan. Red marks delineate automatically borders of RNFL layer. C Presentation of RNFL thickness values for individual sectors and global measurement. D Individual measurement graphically compared to a healthy population.

Retinal vessel diameter measurements in cSLO

Vessel identification in cSLO IR images was performed according to previously reported criteria [25]. Vessel measurements in native cSLO IR images were performed by a semi-automatic “Image-J”-Plugin. The Plugin creates three concentrial rings (diameter: small - 3.2 mm, medium - 3.5 mm, large - 3.8 mm) in the cSLO IR images (Figure 2). The medium ring lies exactly at the level of the circular SD-OCT scan used in RNFL measurement (diameter 3.5 mm). The other two rings of the semi-automated software lie slightly peripherally and centrally to the medium ring. The user labels each vessel as artery or vein and defines vessel measurement lines on all three rings. The software algorithm produces four additional measurements, two above and two below, based on the localization and orientation of each defined measurement point. In total, every vessel is measured at 15 different points. The rings are divided into four quadrants according to RNFL and SD-OCT measurements. A particular strength of the semi-automated technique based on cSLO is that vessel diameters are measured perpendicularly, while the applied SD-OCT scan crosses vessels tangentially according to the peripapillary circle.
Figure 2

Confocal scanning laser (cSLO) infrared image illustrating semi-automatic measurement tool.

Three concentrial circles (blue 3.2 mm, green 3.5 mm, red 3.8 mm) are placed around the optic disc. Vessel labelling marks arteries (a) and veins (v). Measurement lines (cyan) are defined by the software user. Additional measurement lines automatically produced by the software are shown exemplary in artery two (a2; set of five lines). Yellow lines separate superior (S), inferior (I), nasal (N) and temporal (T) quadrant.

Confocal scanning laser (cSLO) infrared image illustrating semi-automatic measurement tool.

Three concentrial circles (blue 3.2 mm, green 3.5 mm, red 3.8 mm) are placed around the optic disc. Vessel labelling marks arteries (a) and veins (v). Measurement lines (cyan) are defined by the software user. Additional measurement lines automatically produced by the software are shown exemplary in artery two (a2; set of five lines). Yellow lines separate superior (S), inferior (I), nasal (N) and temporal (T) quadrant. cSLO IR images of retinal vessels show a central light reflex (CLR) and a dark vessel edge [25]. The software recognizes strong contrasts in reflectivity between outer vessel borders and surrounding retinal tissue, and between the CLR and inner vessel borders respectively (Figure 2). Changes in the vessel wall may alter the reflectivity in cSLO IR images. The reflex diameter may be interpreted as an indicator for the vessel architecture. Measurements were performed for the maximum measurable vessel diameter as well as for the reflex diameter. In both groups, artery-to-vein ratios (AVR) were calculated.

Retinal vessel diameter and vessel wall thickness measurements in SD-OCT

SD-OCT measurements of vessel diameter and vessel wall thickness around the optic disc proved to be highly reproducible and results correlate well with previous histologic studies [17], [18], [26]. Cross-sectional SD-OCT images reveal major retinal vessels as oval configurations with heterogeneous reflectivities, mainly in the RNFL and occasionally in the inner plexiform layer. Physiologic vessels show four distinctive hyperreflectivities. The top and bottom of the vessel walls correlate to the innermost and outermost hyperreflectivities. The arterial walls generally have higher reflectivity compared with the venous walls. Muraoka and colleagues previously reported that retinal vessels with physiologic blood flow show paired hyperreflectivities inside, which are frequently hourglass-shaped (Figure 3) [17]. According to this study, inner and outer vessel diameters of the four largest retinal arteries and veins were measured vertically by two blinded, independent readers (FA, JM) using the built-in manufacturer’s software (Heidelberg Eye Explorer) [17]. A mean value of the two readers as well as AVR values of outer and inner diameter were calculated in CADASIL patients and healthy controls.
Figure 3

A–D Combined simultaneous confocal scanning laser ophthalmoscopy (cSLO) and spectral-domain optical coherence tomography (SD-OCT).

A–B Infrared cSLO image centered on the optic disc of a healthy control subject (A) and a CADASIL patient (B). Green circle indicates the position of corresponding SD-OCT scan. Light green section inferiorly on the circle marks the localization of corresponding SD-OCT scan shown aside. C–D Magnified SD-OCT scans of healthy control subject (C) and CADASIL patient (D) show sections of major retinal vessels appearing as a group of heterogeneous reflectivities in a round-shaped configuration. Asterisks mark the inner and outer reflections of arterial vessel walls and diamonds indicate inner and outer reflections of venous vessel walls. Hyperreflectivities representing the vessel walls seem thicker and more accentuated in the CADASIL patient. Particularly in veins, demarcation of the inferior vessel wall (towards the retinal pigment epithelium) often remains challenging due to absorption effects also seen as acoustical shadow underneath the vessel (towards the retinal pigment epithelium). Note the typical hour-glass shaped configuration within the vessel lumen in both subjects. Lateral vessel walls cannot be visualized as OCT laser beam is not projected perpendicularly to them.

A–D Combined simultaneous confocal scanning laser ophthalmoscopy (cSLO) and spectral-domain optical coherence tomography (SD-OCT).

A–B Infrared cSLO image centered on the optic disc of a healthy control subject (A) and a CADASIL patient (B). Green circle indicates the position of corresponding SD-OCT scan. Light green section inferiorly on the circle marks the localization of corresponding SD-OCT scan shown aside. C–D Magnified SD-OCT scans of healthy control subject (C) and CADASIL patient (D) show sections of major retinal vessels appearing as a group of heterogeneous reflectivities in a round-shaped configuration. Asterisks mark the inner and outer reflections of arterial vessel walls and diamonds indicate inner and outer reflections of venous vessel walls. Hyperreflectivities representing the vessel walls seem thicker and more accentuated in the CADASIL patient. Particularly in veins, demarcation of the inferior vessel wall (towards the retinal pigment epithelium) often remains challenging due to absorption effects also seen as acoustical shadow underneath the vessel (towards the retinal pigment epithelium). Note the typical hour-glass shaped configuration within the vessel lumen in both subjects. Lateral vessel walls cannot be visualized as OCT laser beam is not projected perpendicularly to them. Notably, the same circular SD-OCT scan centered on the optic disc that was used for RNFL analysis was used for manual SD-OCT vessel measurements. Moreover, this scan position is analogous to the medium size ring in cSLO IR vessel measurements. Thus, vessel diameter measurements in cSLO IR and SD-OCT as well as RNFL thickness measurements were performed exactly at the same anatomical localization warranting a thorough comparability of all three methods. As vessel diameters decrease as they run peripherally from the optic disk margin measurement localization is an important criterion [18].

Statistical methods

HRT, ICG, FA and EDI-OCT volume scan was performed in the CADASIL group only while cSLO IR, SD-OCT volume scan and RNFL imaging was conducted in both groups. Both groups were homogeneous in age and gender. Statistical analysis was performed using IBM SPSS Statistics Ver. 22.0.0.0. Vessel diameter values were presented as mean ± standard deviation (SD). In cSLO IR images, all labelable and measureable vessels were used for analysis. Vessel diameters based on manual SD-OCT measurements were calculated using the four largest arteries and four largest veins. U-test and t-test were used to identify differences between control group and study group. A probability value of p<0.05 was considered indicative of statistical significance.

Results

Mean age was 56.2±11.6 (control group: 54.5±10.1) years. Disease severity was as following: Stage I: 5 patients; St. II: 4 patients, St. III: 3 patients, St. IV: 2 patients. Two patients (14%) were clinically asymptomatic. Four (29%) had strokes in the medical history. The MoCA indicated dementia or MCI in 10 patients (71%). Four patients (29%) showed strong signs of dementia. A history of migraine was reported in 7 patients (50%), of whom one suffered from migraine with aura. Two (14%) of them reported a decrease of symptoms with increasing age. BCVA was 0.75±0.25 given as decimal visual acuity values. Spherical equivalent was +0.27±1.39 diopters. One eye suffered from refractive amblyopia. Intraocular pressures were within normal limits. Slit lamp examination revealed no signs of iris atrophy as well as no signs of intraocular inflammation. One patient had a history of unilateral central retinal artery occlusion and showed panretinal laser coagulation spots with ghost vessels as well as an atrophy of the optic nerve head and was consequently excluded from RNFL and vessel analysis. One eye showed a drusen papilla that was excluded from RNFL evaluation. Two patients presented with macro papilla. No functional or morphological signs of glaucoma were present in any patient. Neuroretinal rim volume measured by HRT was 0.33±0.15 mm3. VF testing was performed in all patients except for one patient who was not capable of performing the examination due to his state of health. One patient showed scattered reduction of central and peripheral sensitivity secondary to his history of stroke. One examination was not evaluable due to fixation mistakes. The remaining VF tests were normal (–1.85±1.10 dB MD).

Imaging

CFP and FA revealed neither cotton wool spots nor signs of ischemia in any eye. Sheathed arteries were detected in three eyes of two patients while no patient presented with tortuous arteries. No capillary leakage from blood vessels was seen during FA. Vessels with vascular sheathing also appeared normal during angiography. CFP further revealed arteriovenous nicking in 22 (78.6%) eyes and venous dilation in 24 (85.7%) eyes. RV in OCT volume measurements did not differ significantly between both groups (study group: 8.77±0.46 mm3; control group: 8.85±0.35 mm3; p = 0.341). CV in EDI-OCT volume scans was 8.83±2.24 mm3 in CADASIL patients. ICG revealed a CWZ in 6 (42.9%) CADASIL patients. Otherwise, there was no evidence for choroidal vascular occlusion or hypoperfusion. Mean number of averaging frames was 91.2±17.4. Both groups showed a regular retinal layer configuration. Global RNFL measurements revealed significant differences between both groups (Study group: 105.2 µm; control group: 98.4 µm; p = 0.015). Consequently, a clear significance towards a thicker RNFL in CADASIL patients is evident. (Table 1).
Table 1

Retinal nerve fiber layer thickness (RNFL) measured by spectral-domain optical coherence tomography: healthy controls compared to CADASIL patients.

Peripapillary sectorMean RNFL thickness [µm ± SD]
healthy controlsCADASILp-value
n = 28n = 23
nasal sup. 115.3±26.4121.7±25.20.368
nasal 75.9±13.185.3±13.80.027
nasal inf. 105.1±28.3116.2±24.10.173
temporal inf. 138.1±19.9143.2±18.30.289
temporal 69.9±9.473.0±8.20.254
temporal sup. 136.5±20.8143.3±21.60.244
superior * 125.9±18.5132.5±19.60.349
inferior * 121.6±20.4129.7±16.40.08
global 98.4 ±10.5 105.2 ±9.5 0.015

(n) number of eyes.

*superior and inferior measurements were calculated based on data from nasal superior and temporal superior quadrants and from nasal inferior and temporal inferior quadrants respectively.

(n) number of eyes. *superior and inferior measurements were calculated based on data from nasal superior and temporal superior quadrants and from nasal inferior and temporal inferior quadrants respectively. In the study group, maximum diameters of arteries and veins were 102.5 µm (Control group: 106.0 µm; p = 0.21) and 128.6 µm (124.4 µm; p = 0.27) respectively. Inner reflex diameters of arteries and veins were 32.2 µm (Control group: 30.7 µm; p = 0.13) and 37.2 µm (35.7 µm; p = 0.23) (Table 2). AVR of all vessels based on the maximum diameter was 0.80 for CADASIL patients and 0.85 for healthy controls.
Table 2

Semi-automated vessel measurements based on confocal scanning laser ophthalmoscopy (cSLO): healthy controls compared to CADASIL patients.

VesselPeripapillarysectorMean [µm ± SD]
healthy controlsCADASILp-value
n = 28vn = 25v
Arteries
Max diameternasal94.16±20.335388.95±20.96510.201
superior109.98±29.3266110.43±24.94630.926
temporal89.03±21.391185.03±21.56160.639
inferior112.55±27.9960109.48±27.39600.545
global 105.99 ±27.92 190102.49 ±26.74 1900.213
Inner reflexdiameternasal25.68±10.544027.93±8.23430.280
superior32.10±8.006434.47±8.26610.106
temporal26.25±10.031127.01±8.15140.836
inferior33.22±8.445534.53±9.25540.441
global 30.68 ±9.42 17032.19 ±9.17 1720.134
Veins
Max diameternasal111.33±19.0730103.93±20.32350.137
superior123.02±27.2666133.61±36.28580.067
temporal81.34±4.96154.42±1.932n/a
inferior132.62±31.0251139.98±36.44500.277
global 124.38 ±28.74 148128.61 ±36.60 1450.272
Inner reflexdiameternasal32.66±7.072131.26±8.80260.558
superior34.80±8.296337.88±10.47510.082
temporal25.21±2.8312.83±5.111n/a
inferior38.45±7.774740.80±11.64480.251
global 35.74 ±8.22 13237.22 ±11.53 1260.235

(n) number of total eyes; (v) number of total vessels; (n/a) too few vessels in the respective sector to calculate p-value.

(n) number of total eyes; (v) number of total vessels; (n/a) too few vessels in the respective sector to calculate p-value. High quality SD-OCT images are crucial to perform accurate vessel diameter and vessel wall thickness measurements. A clear demarcation was required between inner vessel wall and vessel lumen as well as outer vessel wall and retinal tissue. Due to questionable border discrimination of vessel walls, two arteries and three veins were excluded in the healthy control group as well as three veins in the study group. At vessel crossing points and in case of close vicinity of vessels, SD-OCT offers better vessel border discrimination compared to cSLO. Modification of contrast in SD-OCT scans slightly improved border discrimination particularly in arteries. Mean arterial and venous outer diameters were 138.7 µm (Control group: 125.38 µm; p<0.001) and 160.0 µm (146.9 µm; p = 0.003). Mean inner arterial and venous diameters were 84.0 µm (87.0 µm; p = 0.238) and 123.4 µm (115.5 µm; p = 0.05). Vessel wall thickness was calculated as difference between outer and inner vessel diameter measurements. Mean wall thickness was 27.4 µm (19.2 µm; p<0.001) in arteries and 18.3 µm (15.7 µm; p<0.001) in veins (Table 3). AVR values of inner and outer diameters of CADASIL patients were AVRout 0.87, AVRin 0.68 and for healthy controls AVRout 0.85, AVRin 0.75.
Table 3

Manual vessel measurements using spectral-domain optical coherence tomography (SD-OCT): healthy controls compared to CADASIL patients.

VesselMean [µm±SD]
healthy controlsCADASILp-value
n = 28n = 25
Arteries Outer diameter125.38±19.42138.71±20.25<0.001
Inner diameter87.02±17.0683.99±18.760.238
Vessel wall19.18±3.0327.36±4.47<0.001
Veins Outer diameter146.92±25.72159.95±32.970.003
Inner diameter115.47±24.38123.35±30.630.05
Vessel wall15.73±2.9918.30±4.91<0.001

(n) number of eyes.

(n) number of eyes.

Discussion

CADASIL has gained increasing interest as a model for the more common forms of ischemic cerebral small-artery diseases and subcortical ischemic vascular dementia [27]. CADASIL is characterized by a thickening of the arterial wall leading to lumen stenosis, the presence of a non-amyloid granular osmiophilic material within the media extending into the adventitia, as well as morphological alterations of smooth-muscle cells [28], [29]. Cerebral and retinal arterioles share a similar anatomy, physiology, and embryology and there is evidence for an association between retinal vessel changes and cerebral small vessel disease [30], [31]. The aim of our study was to benefit from recent advances in in-vivo retinal imaging and to analyze and re-evaluate previously reported retinal findings and retinal vessel changes in CADASIL patients. To our knowledge, this is the first study to apply these refined in-vivo imaging tools to CADASIL patients and to report detected changes in vessel architecture due to this pathology. Functional data as well as funduscopic findings like vascular sheathing, arteriovenous nicking and venous dilation are in line with previous reports [3]–[12]. The prevalence of single findings may vary as different study groups are certainly heterogeneous regarding the clinical stage of included patients and usually contain only a limited number of patients. Previous histologic data revealed that ocular vessel pathologies in CADASIL patients are limited to retinal vessels only, while choroidal vessels are unaffected [5]. For the first time, we report in-vivo imaging data on the choroid of CADASIL patients that clinically confirm former histologic findings. Neither ICG nor EDI-OCT imaging revealed pathologic findings in the study group. The CV as well as the number of CWZ are in line with previously reported data of healthy probands [23], [32], [33]. RNFL measurements in CADASIL patients based on previous generation time-domain OCT instruments consistently showed a significant reduction in peripapillary RNFL thickness [6]–[8]. SD-OCT allows a refined RNFL analysis around the optic disc with a differentiated eight sector analysis grid. Interestingly, our measurements revealed an increased global RNFL thickness in CADASIL patients. As retinal vessels run within the RNFL for the most part, this finding suggests that a pathologic thickening of peripapillary retinal vessels in CADASIL patients, as seen histopathologically, may result in an increase of global RNFL thickness [2]. Considering the anatomic distribution of peripapillary vessel trunks one may consequently hypothesize that this finding must be particularly found in the vessel rich superior and inferior sectors potentially serving as an additional marker of vessel alteration in CADASIL patients. Yet, a significant increase in those vessel rich sectors was not found for supporting this thesis. An increase in RNFL thickness in CADASIL patients certainly is an interesting finding, and it might be interpreted as a result of vessel thickening. However, previous studies on RNFL measurements in CADASIL patients report a decrease in RNFL thickness [6]–[8]. These contradictory results suggest that RNFL measurements currently do not appear suitable as screening or follow-up tool in this patient group and require further research. Fischer et al. previously described the challenge of visualizing and measuring outer vessel diameters in native cSLO IR images as borders between retinal vessels and surrounding tissue often become indistinct. Similarly to funduscopy, the authors postulate that native cSLO IR only captures inner vessel diameter, while vessel outer diameters as well as vessel walls remain undetectable [34]. We found no significant changes in the arterial and venous maximum diameter in CADASIL patients using native cSLO IR imaging. Based on the hypothesis by Fischer and colleagues, these measurements can be interpreted as inner vessel diameter. Previous studies controversially discussed the value of retinal vessel characteristics such as AVR representing factors for assessing vascular status or even risk assessment. Ikram and co-workers reported that increased retinal venous calibers are associated with stroke and progression of cerebral small vessel disease [35], [36]. As CADASIL patients represent a high risk group for stroke, a venous dilatation in retinal vessels could be expected in these patients. Contrary, Chui et al. recently postulated that vessel walls are detectable using adaptive optics cSLO [37]. Additionally, our data shows AVR values higher than 0.8 in cSLO IR imaging in both groups, which gives rise to doubts whether cSLO IR in fact measures inner vessel diameters considering that AVR values of about 2/3 for the inner vessel diameter were reported previously [34], [38]. We use the term ‘maximum vessel diameter’ for the diameter measured in cSLO IR images. Regardless of the question whether cSLO records the inner or outer diameter, we did not find significant changes in the maximum diameters between healthy controls and CADASIL patients suggesting that pathologic structural vessel changes in CADASIL are not accessible to native cSLO IR imaging. Goldenberg et al recently proposed a non-invasive, in-vivo method for measuring retinal vessel caliber based on SD-OCT [18]. Furthermore, Muraoka and colleagues proved that measuring retinal vessel walls in healthy subjects and in patients is reliable using a manual measurement tool in SD-OCT [16], [17]. A paired, frequently hourglass-shaped hyperreflectivity inside the vessels was observed in healthy subjects and interpreted as result of physiologic blood flow. As previously described, this pattern is substantially altered in patients suffering from retinal vein occlusion [16]. In our study group as well as in our control group, the hourglass-shaped hyperreflectivity was consistently seen suggesting that blood flow is not severely disturbed in major retinal vessels of CADASIL patients (Figure 3). Manual vessel measurements using SD-OCT revealed that the outer diameter in arteries and veins in CADASIL patients was highly significantly thicker than in healthy subjects. Moreover, the vessel wall was highly significantly thicker in both venous and arterial vessels. An important difference between arteries and veins is the inner diameter. In veins, the inner diameter i.e. the lumen showed significantly higher values in CADASIL subjects. The inner diameter of arteries in CADASIL patients did not reveal a significant difference, yet, the arterial lumina tended to narrow. If thickening of arteries in CADASIL patients affects lumen diameters is still subject of debate. Dong et al recently confirmed a substantial thickening of leptomeningeal arteries of CADASIL patients, which is primarily a result of distinct intimal hyperplasia that does not affect lumen diameter [39]. AVR values of healthy controls revealed a considerable difference between outer and inner diameters suggesting that unlike cSLO IR, SD-OCT allows for differentiating between outer and inner diameters. In 2006, Roine et al reported significantly lower AVR values (0.53) in 33 CADASIL patients compared to healthy controls (0.61) based on fundus photography, which approximately corresponds to our inner diameter AVR values based on manual SD-OCT [10]. This additionally supports the notion that fundus photography shows inner diameters, while cSLO IR does not. Measurements of our healthy control group are in accordance with recently reported data [16], [17]. In summary, using manual SD-OCT measurements CADASIL patients revealed a distinct difference in inner and outer diameter as well as in vessel wall thickness in both arteries and veins not only compared to our control group but also to measurements of larger healthy populations from the literature (Table 4).
Table 4

Data overview regarding manual retinal vessel measurements based on spectral-domain optical coherence tomography.

VesselMean [µm ± SD]
Goldberg et al* Muraoka et al# healthy controls# CADASIL#
n = 29n = 238n = 14n = 14
Arteries Outer diameter127.8±13.4122.5±13.1125.38±19.42138.71±20.25
Inner diameter87.8±9.487.02±17.0683.99±18.76
Vessel wall17.4±2.419.18±3.0327.36±4.47
Veins Outer diameter145.3±15141± 13.1146.92± 25.72159.95±32.97
Inner diameter113.7±12.5115.47± 24.38123.35±30.63
Vessel wall13.7±2.115.73± 2.9918.30±4.91

(n) number of patients.

*measurements performed at 960 µm from the optic disc edge.

circular SD-OCT scan 3.5 mm in diameter.

(n) number of patients. *measurements performed at 960 µm from the optic disc edge. circular SD-OCT scan 3.5 mm in diameter. Manual vessel measurements in peripapillary SD-OCT scans allow for in-vivo identification of vessel walls, outer and inner diameter of retinal arteries and veins in CADASIL patients. This technique visualizes morphologic changes in vessel architecture reflecting histologic and pathophysiologic knowledge on this disease. Obviously, the small number of subjects included in the study precludes any definitive interpretation. Yet, CADASIL is a rare disease and in those patients included diagnosis was confirmed by genetic testing and vessel biopsy. Furthermore, the clinical stage of the disease was heterogeneous within the study group. As automated software is not commercially available, retinal vessel diameters had to be measured manually on SD-OCT sections. Study results must be interpreted cautiously bearing in mind that SD-OCT does allow for highlighting differences of reflectivity within the human retina in-vivo, however, no strict correlations with histology have been demonstrated yet. So far it remains unclear, for instance, which vessel wall layer or which property of the vessel wall results in hyper- or hyporeflectivities seen in SD-OCT. Therefore, one cannot assume for sure that the identified and measured reflectivities in this study in fact represent the entire vessel wall. Furthermore, all depicted vessels within an SD-OCT scan are captured by the laser beam in various angles, which may lead to altered reflection properties of each individual vessel wall. Finally, absorption effects of the inner vessel tissue (towards the vitreous) may cause a challenging demarcation of outer vessel walls (towards the RPE) particularly in venous vessels since veins exhibit a weaker reflectivity signal compared to arteries due to their different wall architecture. These facts certainly limit the validity of morphologic changes in vessel wall thickness observed in SD-OCT. Regarding continuous improvements in retinal imaging, retinal vessel analysis may become more relevant not only in ophthalmologic but also in systemic and neurologic diseases [40]. In the near future, adaptive optics SLO appears to be the next step in in-vivo retinal imaging as it is increasingly capable of non-invasively detecting and monitoring morphological changes within retinal vascular wall morphology [37]. Image acquisition using adaptive optics systems and the subsequent image processing is extremely time consuming, which currently limits widespread clinical application. This is the first study to report retinal findings and retinal vessel measurements in CADASIL patients based on high resolution imaging. CADASIL patients revealed a thicker RNFL caused by enlarged vessel diameters. Increased retinal venous lumina, a known risk factor for stroke, were found in manual SD-OCT measurements. Thickened vessel walls as found in manual SD-OCT measurements correspond to previous histologic reports. Finally, reduced arterial vessel lumina as shown in SD-OCT represent the ischemic component of this disease. In the future, retinal imaging will certainly not replace MRI in CADASIL patients as it is indispensable for detection of cerebral damage as well as for differential diagnosis. Nevertheless, besides MRI, genetic diagnostic and immunohistology, high resolution retinal vessel imaging may be accounted as a complementary tool to diagnose and follow-up CADASIL patients and other cerebral small-vessel diseases in the future.
  39 in total

1.  Retinal findings in cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (cadasil).

Authors:  W Robinson; S L Galetta; L McCluskey; M S Forman; L J Balcer
Journal:  Surv Ophthalmol       Date:  2001 Mar-Apr       Impact factor: 6.048

2.  Imaging of vascular wall fine structure in the human retina using adaptive optics scanning laser ophthalmoscopy.

Authors:  Toco Y P Chui; Thomas J Gast; Stephen A Burns
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-10-29       Impact factor: 4.799

3.  Skin biopsy immunostaining with a Notch3 monoclonal antibody for CADASIL diagnosis.

Authors:  A Joutel; P Favrole; P Labauge; H Chabriat; C Lescoat; F Andreux; V Domenga; M Cécillon; K Vahedi; A Ducros; F Cave-Riant; M G Bousser; E Tournier-Lasserve
Journal:  Lancet       Date:  2001-12-15       Impact factor: 79.321

4.  Retinal vessel diameter measurements by spectral domain optical coherence tomography.

Authors:  Yanling Ouyang; Qing Shao; Dirk Scharf; Antonia M Joussen; Florian M Heussen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-08-17       Impact factor: 3.117

5.  Retinal microvascular abnormalities and incident stroke: the Atherosclerosis Risk in Communities Study.

Authors:  T Y Wong; R Klein; D J Couper; L S Cooper; E Shahar; L D Hubbard; M R Wofford; A R Sharrett
Journal:  Lancet       Date:  2001-10-06       Impact factor: 79.321

6.  Advanced intimal hyperplasia without luminal narrowing of leptomeningeal arteries in CADASIL.

Authors:  Hairong Dong; Haixia Ding; Kelly Young; Mila Blaivas; Paul J Christensen; Michael M Wang
Journal:  Stroke       Date:  2013-03-12       Impact factor: 7.914

7.  Retinal ganglion cell and inner plexiform layer thinning in clinically isolated syndrome.

Authors:  Timm Oberwahrenbrock; Marius Ringelstein; Simon Jentschke; Katrin Deuschle; Katharina Klumbies; Judith Bellmann-Strobl; Jens Harmel; Klemens Ruprecht; Sven Schippling; Hans-Peter Hartung; Orhan Aktas; Alexander U Brandt; Friedemann Paul
Journal:  Mult Scler       Date:  2013-05-23       Impact factor: 6.312

8.  Age- and hypertension-dependent changes in retinal vessel diameter and wall thickness: an optical coherence tomography study.

Authors:  Yuki Muraoka; Akitaka Tsujikawa; Kyoko Kumagai; Masahiro Akiba; Ken Ogino; Tomoaki Murakami; Yumiko Akagi-Kurashige; Kazuaki Miyamoto; Nagahisa Yoshimura
Journal:  Am J Ophthalmol       Date:  2013-07-20       Impact factor: 5.258

9.  Visual system involvement in CADASIL.

Authors:  Elena Pretegiani; Francesca Rosini; Maria T Dotti; Silvia Bianchi; Antonio Federico; Alessandra Rufa
Journal:  J Stroke Cerebrovasc Dis       Date:  2013-04-28       Impact factor: 2.136

10.  Vessel labeling in combined confocal scanning laser ophthalmoscopy and optical coherence tomography images: criteria for blood vessel discrimination.

Authors:  Jeremias Motte; Florian Alten; Carina Ewering; Nani Osada; Ella M Kadas; Alexander U Brandt; Timm Oberwahrenbrock; Christoph R Clemens; Nicole Eter; Friedemann Paul; Martin Marziniak
Journal:  PLoS One       Date:  2014-09-09       Impact factor: 3.240

View more
  11 in total

Review 1.  Optical Coherence Tomography Angiography in Neurodegenerative Diseases: A Review.

Authors:  Georgios Tsokolas; Konstantinos T Tsaousis; Vasilios F Diakonis; Artemis Matsou; Straton Tyradellis
Journal:  Eye Brain       Date:  2020-07-14

Review 2.  Past, present and future role of retinal imaging in neurodegenerative disease.

Authors:  Amir H Kashani; Samuel Asanad; Jane W Chan; Maxwell B Singer; Jiong Zhang; Mona Sharifi; Maziyar M Khansari; Farzan Abdolahi; Yonggang Shi; Alessandro Biffi; Helena Chui; John M Ringman
Journal:  Prog Retin Eye Res       Date:  2021-01-15       Impact factor: 19.704

3.  Study of Enhanced Depth Imaging Optical Coherence Tomography in Cerebral Autosomal Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy.

Authors:  Xiao-Jing Fang; Meng Yu; Yuan Wu; Zi-Hao Zhang; Wei-Wei Wang; Zhao-Xia Wang; Yun Yuan
Journal:  Chin Med J (Engl)       Date:  2017-05-05       Impact factor: 2.628

4.  OCT-Angiography reveals reduced vessel density in the deep retinal plexus of CADASIL patients.

Authors:  Pieter Nelis; Ilka Kleffner; Matthias C Burg; Christoph R Clemens; Maged Alnawaiseh; Jeremias Motte; Martin Marziniak; Nicole Eter; Florian Alten
Journal:  Sci Rep       Date:  2018-05-25       Impact factor: 4.379

Review 5.  Retinal Vascular Imaging in Vascular Cognitive Impairment: Current and Future Perspectives.

Authors:  Oana M Dumitrascu; Touseef A Qureshi
Journal:  J Exp Neurosci       Date:  2018-09-20

6.  Retinal Artery Contraction After Phenylephrine as a Cardiovascular Risk Biomarker.

Authors:  Alfonso Casado; Alicia López-de-Eguileta; Soraya Fonseca; Andrea Cerveró; Jorge Gaitán
Journal:  Clin Ophthalmol       Date:  2020-05-11

Review 7.  The Value of Optical Coherence Tomography Angiography (OCT-A) in Neurological Diseases.

Authors:  Albert J Augustin; Jenny Atorf
Journal:  Diagnostics (Basel)       Date:  2022-02-11

8.  Retinal biomarkers of Cerebral Small Vessel Disease: A systematic review.

Authors:  Elena Biffi; Zachary Turple; Jessica Chung; Alessandro Biffi
Journal:  PLoS One       Date:  2022-04-14       Impact factor: 3.240

9.  Evaluation of Retinal Vessel Morphology in Patients with Parkinson's Disease Using Optical Coherence Tomography.

Authors:  Robert Kromer; Carsten Buhmann; Ute Hidding; Matthias Keserü; Diana Keserü; Andrea Hassenstein; Birthe Stemplewitz
Journal:  PLoS One       Date:  2016-08-15       Impact factor: 3.240

10.  Chromosome 10q26-driven age-related macular degeneration is associated with reduced levels of HTRA1 in human retinal pigment epithelium.

Authors:  Brandi L Williams; Nathan A Seager; Jamie D Gardiner; Chris M Pappas; Monica C Cronin; Cristina Amat di San Filippo; Robert A Anstadt; Jin Liu; Marc A Toso; Lisa Nichols; Timothy J Parnell; Jacqueline R Eve; Paul L Bartel; Moussa A Zouache; Burt T Richards; Gregory S Hageman
Journal:  Proc Natl Acad Sci U S A       Date:  2021-07-27       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.