Literature DB >> 23876868

Age- and hypertension-dependent changes in retinal vessel diameter and wall thickness: an optical coherence tomography study.

Yuki Muraoka1, Akitaka Tsujikawa, Kyoko Kumagai, Masahiro Akiba, Ken Ogino, Tomoaki Murakami, Yumiko Akagi-Kurashige, Kazuaki Miyamoto, Nagahisa Yoshimura.   

Abstract

PURPOSE: To validate and evaluate the reliability of retinal vessel diameter measurements by optical coherence tomography (OCT). The effects of age and hypertension on vessel diameter were also examined.
DESIGN: Prospective, cross-sectional study.
METHODS: Two hundred thirty-eight eyes (238 subjects) with no ocular disease were included. Hypertension was present in 106 subjects and absent in 132 subjects. Spectralis HRA+OCT was used to scan a circular region around the optic disc. Outer and inner diameters of the 4 largest retinal arteries and veins were measured using OCT vascular wall reflections, and vessel wall thickness was calculated.
RESULTS: Intervisit, interexaminer, and interevaluator intraclass correlation coefficients of randomly selected vessel measurements were all greater than 0.90. Mean inner arterial and venous diameters were 87.8 ± 9.4 μm and 113.7 ± 12.5 μm, respectively. The OCT-measured mean inner arterial and venous diameters were significantly correlated to fundus photography caliber measurements (P = .005 and P = .001, respectively). Arterial and venous wall thicknesses were 17.4 ± 2.4 μm and 13.7 ± 2.1 μm, respectively, both of which were highly correlated with subject age (arterial: r = 0.612, P < .001, venous: r = 0.455, P < .001). Additionally, both mean arterial and venous wall thicknesses were significantly greater in subjects with hypertension than in age-matched subjects without hypertension (P = .020 and P = .015, respectively).
CONCLUSIONS: Retinal vessel diameter measurements obtained with OCT were highly reproducible and vessel wall thicknesses, calculated using outer and inner diameter measurements, were significantly thickened by both aging and systemic hypertension.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23876868     DOI: 10.1016/j.ajo.2013.05.021

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  35 in total

1.  Recurrence of macular edema in eyes with branch retinal vein occlusion changes the diameter of unaffected retinal vessels.

Authors:  Jong Chan Im; Jae Pil Shin; In Taek Kim; Dong Ho Park
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-11-20       Impact factor: 3.117

2.  Recurrence of macular edema in eyes with branch retinal vein occlusion changes the diameter of unaffected retinal vessels.

Authors:  Umit Yolcu; Abdullah Ilhan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-11-19       Impact factor: 3.117

3.  Retinal vessel structure measurement using spectral-domain optical coherence tomography.

Authors:  T H Rim; Y S Choi; S S Kim; M-J Kang; J Oh; S Park; S H Byeon
Journal:  Eye (Lond)       Date:  2015-10-23       Impact factor: 3.775

Review 4.  The clinical implications of recent studies on the structure and function of the retinal microvasculature in diabetes.

Authors:  Carol Yimlui Cheung; M Kamran Ikram; Ronald Klein; Tien Yin Wong
Journal:  Diabetologia       Date:  2015-02-11       Impact factor: 10.122

5.  Systemic Determinants of Peripapillary Vessel Density in Healthy African Americans: The African American Eye Disease Study.

Authors:  Ryuna Chang; Andrew J Nelson; Vivian LeTran; Brian Vu; Bruce Burkemper; Zhongdi Chu; Ali Fard; Amir H Kashani; Benjamin Y Xu; Ruikang K Wang; Rohit Varma; Grace M Richter
Journal:  Am J Ophthalmol       Date:  2019-06-21       Impact factor: 5.258

6.  Evaluating retinal vessel diameter with optical coherence tomography in normal-tension glaucoma patients.

Authors:  Takeshi Yabana; Yukihiro Shiga; Ryo Kawasaki; Kazuko Omodaka; Hidetoshi Takahashi; Koudai Kimura; Kyosuke Togashi; Takaaki Horii; Kei Sasaki; Testuya Yuasa; Toru Nakazawa
Journal:  Jpn J Ophthalmol       Date:  2017-06-30       Impact factor: 2.447

7.  Evaluation of the effect of fluorescein angiography on retinal vessel diameter: an optical coherence tomography study.

Authors:  Metin Unlu; Duygu Gülmez Sevim; Cagatay Karaca; Bahadir Duzgun; Ayse Ozturk Oner; Ertugrul Mirza
Journal:  Int Ophthalmol       Date:  2016-12-30       Impact factor: 2.031

8.  Retinal vessel diameter measurements by spectral domain optical coherence tomography.

Authors:  Yanling Ouyang; Qing Shao; Dirk Scharf; Antonia M Joussen; Florian M Heussen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-08-17       Impact factor: 3.117

9.  Comparison of retinal vessel measurements using adaptive optics scanning laser ophthalmoscopy and optical coherence tomography.

Authors:  Shigeta Arichika; Akihito Uji; Sotaro Ooto; Yuki Muraoka; Nagahisa Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2016-02-23       Impact factor: 2.447

Review 10.  Retinal vascular imaging in early life: insights into processes and risk of cardiovascular disease.

Authors:  Ling-Jun Li; Mohammad Kamran Ikram; Tien Yin Wong
Journal:  J Physiol       Date:  2015-11-23       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.