Literature DB >> 25371457

Comparison between 28 mm and 32 mm ceramic-on-ceramic bearings in total hip replacement.

Y K Lee1, Y C Ha2, K H Koo1.   

Abstract

Large femoral heads have become popular in total hip replacement (THR) as a method of reducing the risk of dislocation. However, if large heads are used in ceramic-on-ceramic THR, the liner must be thinner, which may increase the risk of fracture. To compare the rates of ceramic fracture and dislocation between 28 mm and 32 mm ceramic heads, 120 hips in 109 patients (51 men and 58 women, mean age 49.2 years) were randomised to THR with either a 28 mm or a 32 mm ceramic articulation. A total of 57/60 hips assigned to the 28 mm group and 55/60 hips assigned to the 32 mm group were followed for at least five years. No ceramic component fractures occured in any patient in either group. There was one dislocation in the 32 mm group and none in the 28 mm group (p = 0.464). No hip had detectable wear, focal osteolysis or prosthetic loosening. In our small study the 32 mm ceramic articulation appeared to be safe in terms of ceramic liner fracture. ©2014 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Head size; Total hip replacement; Bearings; Ceramic; ceramic fracture; dislocation

Mesh:

Year:  2014        PMID: 25371457     DOI: 10.1302/0301-620X.96B11.34358

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  4 in total

1.  Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve.

Authors:  Seung-Jae Lim; Seung-Pil Jang; Dong-Wook Kim; Young-Wan Moon; Youn-Soo Park
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

2.  Outcome of Ceramic-on-Ceramic Total Hip Arthroplasty with 4th Generation 36 mm Head Compared to that with 3rd Generation 28 mm Head by Propensity Score Matching.

Authors:  Soong Joon Lee; Kang Sup Yoon
Journal:  Indian J Orthop       Date:  2020-09-02       Impact factor: 1.251

3.  Midterm analysis of the seleXys cup with ceramic inlay.

Authors:  Tamas Halasi; David Kieser; Christopher M A Frampton; Gary J Hooper
Journal:  Arthroplast Today       Date:  2016-11-09

4.  Fragility Index as a Measure of Randomized Clinical Trial Quality in Adult Reconstruction: A Systematic Review.

Authors:  Carl L Herndon; Kyle L McCormick; Anastasia Gazgalis; Elise C Bixby; Matthew M Levitsky; Alexander L Neuwirth
Journal:  Arthroplast Today       Date:  2021-10-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.