Dong Liu1, Christopher L Brace1. 1. Departments of Radiology and Biomedical Engineering, University of Wisconsin, Madison, Wisconsin 53705.
Abstract
PURPOSE: To analyze the spatial distribution and temporal development of liver tissue contraction during high-temperature ablation by using intraprocedural computed tomography (CT) imaging. METHODS: A total of 46 aluminum fiducial markers were positioned in a 60 × 45 mm grid, in a single plane, around a microwave ablation antenna in each of six ex vivo bovine liver samples. Ablations were performed for 10 min at 100 W. CT data of the liver sample were acquired every 30 s during ablation. Fiducial motion between acquisitions was tracked in postprocessing and used to calculate measures of tissue contraction and contraction rates. The spatial distribution and temporal evolution of contraction were analyzed. RESULTS: Fiducial displacement indicated that the zone measured postablation was 8.2 ± 1.8 mm (∼20%) smaller in the radial direction and 7.1 ± 1.0 mm (∼10%) shorter in the longitudinal direction than the preablation tissue dimension. Therefore, the total ablation volume was reduced from its preablation value by approximately 45%. Very little longitudinal contraction was noted in the distal portion of the ablation zone. Central tissues contracted more than 60%, which was near an estimated limit of ∼70% based on initial water content. More peripheral tissues contracted only 15% in any direction. Contraction rates peaked during the first 60 s of heating with a roughly exponential decay over time. CONCLUSIONS: Ablation zones measured posttreatment are significantly smaller than the pretreatment tissue dimensions. Tissue contraction is spatially dependent, with the greatest effect occurring in the central ablation zone. Contraction rate peaks early and decays over time.
PURPOSE: To analyze the spatial distribution and temporal development of liver tissue contraction during high-temperature ablation by using intraprocedural computed tomography (CT) imaging. METHODS: A total of 46 aluminum fiducial markers were positioned in a 60 × 45 mm grid, in a single plane, around a microwave ablation antenna in each of six ex vivo bovine liver samples. Ablations were performed for 10 min at 100 W. CT data of the liver sample were acquired every 30 s during ablation. Fiducial motion between acquisitions was tracked in postprocessing and used to calculate measures of tissue contraction and contraction rates. The spatial distribution and temporal evolution of contraction were analyzed. RESULTS: Fiducial displacement indicated that the zone measured postablation was 8.2 ± 1.8 mm (∼20%) smaller in the radial direction and 7.1 ± 1.0 mm (∼10%) shorter in the longitudinal direction than the preablation tissue dimension. Therefore, the total ablation volume was reduced from its preablation value by approximately 45%. Very little longitudinal contraction was noted in the distal portion of the ablation zone. Central tissues contracted more than 60%, which was near an estimated limit of ∼70% based on initial water content. More peripheral tissues contracted only 15% in any direction. Contraction rates peaked during the first 60 s of heating with a roughly exponential decay over time. CONCLUSIONS: Ablation zones measured posttreatment are significantly smaller than the pretreatment tissue dimensions. Tissue contraction is spatially dependent, with the greatest effect occurring in the central ablation zone. Contraction rate peaks early and decays over time.
Authors: G D Dodd; M C Soulen; R A Kane; T Livraghi; W R Lees; Y Yamashita; A R Gillams; O I Karahan; H Rhim Journal: Radiographics Date: 2000 Jan-Feb Impact factor: 5.333
Authors: Christopher L Brace; Paul F Laeseke; Daniel W van der Weide; Fred T Lee Journal: IEEE Trans Microw Theory Tech Date: 2005-01 Impact factor: 3.599
Authors: Tito Livraghi; Luigi Solbiati; M Franca Meloni; G Scott Gazelle; Elkan F Halpern; S Nahum Goldberg Journal: Radiology Date: 2003-02 Impact factor: 11.105
Authors: Maria Franca Meloni; Jason Chiang; Paul F Laeseke; Christoph F Dietrich; Angela Sannino; Marco Solbiati; Elisabetta Nocerino; Christopher L Brace; Fred T Lee Journal: Int J Hyperthermia Date: 2016-08-02 Impact factor: 3.914
Authors: Francesco De Cobelli; Paolo Marra; Francesca Ratti; Alessandro Ambrosi; Michele Colombo; Anna Damascelli; Claudio Sallemi; Simone Gusmini; Marco Salvioni; Pietro Diana; Federica Cipriani; Massimo Venturini; Luca Aldrighetti; Alessandro Del Maschio Journal: Med Oncol Date: 2017-02-20 Impact factor: 3.064
Authors: E Ghahramani Z; P D Grimm; K J Eary; M P Swearengen; E G Sunethra K Dayavansha; T D Mast Journal: J Acoust Soc Am Date: 2022-06 Impact factor: 2.482
Authors: Robert M Pohlman; James L Hinshaw; Timothy J Ziemlewicz; Meghan G Lubner; Shane A Wells; Fred T Lee; Marci L Alexander; Kelly L Wergin; Tomy Varghese Journal: Ultrasound Med Biol Date: 2021-05-16 Impact factor: 3.694
Authors: Robert Peter Reimer; Nils Große Hokamp; Julius Niehoff; David Zopfs; Simon Lennartz; Mariam Heidar; Roger Wahba; Dirk Stippel; David Maintz; Daniel Pinto Dos Santos; Christian Wybranski Journal: PLoS One Date: 2021-06-15 Impact factor: 3.240