Literature DB >> 25367780

Comparison between simulated decoupling regimes for specific absorption rate prediction in parallel transmit MRI.

Arian Beqiri1, Jeffrey W Hand1, Joseph V Hajnal1,2, Shaihan J Malik1.   

Abstract

PURPOSE: The use of electromagnetic (EM) modeling is critical for specific absorption rate (SAR) characterization in parallel transmission MRI. Radiofrequency arrays that include decoupling networks can be difficult to characterize accurately in simulation. A practical method of simplifying modeling is to exclude the decoupling networks and model each transmit element in isolation. Results from this type of model can be related to a real device by applying "active decoupling" to the real device to suppress residual coupling when in use. Here, we compare this approach with a full model that includes decoupling networks.
METHODS: EM simulations for a variety of adult male voxel models placed within an eight-channel transverse electromagnetic (TEM) array tuned for 3 Tesla operation were run with and without decoupling networks included. The resulting EM fields and SAR estimates were compared using basic normalization, and simulated active decoupling.
RESULTS: Modeling the transmit elements independently leads to variations which have significantly different SAR estimates of ∼20% on average compared with the full model if not normalized appropriately. After "active decoupling," SAR was still generally seen to be overestimated by ∼7% with independent channel modeling; despite having similar B1(+) field distributions.
CONCLUSION: Modeling transmission elements independently may lead to substantially incorrect SAR estimates if the corresponding MRI system is not run in an analogous manner.
© 2014 Wiley Periodicals, Inc.

Keywords:  SAR; modeling; parallel transmission

Mesh:

Year:  2014        PMID: 25367780     DOI: 10.1002/mrm.25504

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Development, validation, and pilot MRI safety study of a high-resolution, open source, whole body pediatric numerical simulation model.

Authors:  Hongbae Jeong; Georgios Ntolkeras; Michel Alhilani; Seyed Reza Atefi; Lilla Zöllei; Kyoko Fujimoto; Ali Pourvaziri; Michael H Lev; P Ellen Grant; Giorgio Bonmassar
Journal:  PLoS One       Date:  2021-01-13       Impact factor: 3.240

2.  Bench to bore ramifications of inter-subject head differences on RF shimming and specific absorption rates at 7T.

Authors:  Benjamin M Hardy; Rana Banik; Xinqiang Yan; Adam W Anderson
Journal:  Magn Reson Imaging       Date:  2022-07-13       Impact factor: 3.130

3.  The Coax Dipole: A fully flexible coaxial cable dipole antenna with flattened current distribution for body imaging at 7 Tesla.

Authors:  Carel C van Leeuwen; Bart R Steensma; Dennis W J Klomp; Cornelis A T van den Berg; Alexander J E Raaijmakers
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 3.737

4.  In vivo human head MRI at 10.5T: A radiofrequency safety study and preliminary imaging results.

Authors:  Alireza Sadeghi-Tarakameh; Lance DelaBarre; Russell L Lagore; Angel Torrado-Carvajal; Xiaoping Wu; Andrea Grant; Gregor Adriany; Gregory J Metzger; Pierre-Francois Van de Moortele; Kamil Ugurbil; Ergin Atalar; Yigitcan Eryaman
Journal:  Magn Reson Med       Date:  2019-11-21       Impact factor: 4.668

5.  Electromagnetic simulation of a 16-channel head transceiver at 7 T using circuit-spatial optimization.

Authors:  Xin Li; Jullie W Pan; Nikolai I Avdievich; Hoby P Hetherington; Joseph V Rispoli
Journal:  Magn Reson Med       Date:  2021-02-03       Impact factor: 3.737

6.  Assessment of radio-frequency heating of a parallel transmit coil in a phantom using multi-echo proton resonance frequency shift thermometry.

Authors:  Hongbae Jeong; Matthew C Restivo; Peter Jezzard; Aaron T Hess
Journal:  Magn Reson Imaging       Date:  2020-12-29       Impact factor: 2.546

7.  Personalized local SAR prediction for parallel transmit neuroimaging at 7T from a single T1-weighted dataset.

Authors:  Wyger M Brink; Sahar Yousefi; Prernna Bhatnagar; Rob F Remis; Marius Staring; Andrew G Webb
Journal:  Magn Reson Med       Date:  2022-03-28       Impact factor: 3.737

8.  Phase relaxed localized excitation pulses for inner volume fast spin echo imaging.

Authors:  Shaihan J Malik; Joseph V Hajnal
Journal:  Magn Reson Med       Date:  2015-10-09       Impact factor: 4.668

9.  Extended RF shimming: Sequence-level parallel transmission optimization applied to steady-state free precession MRI of the heart.

Authors:  Arian Beqiri; Anthony N Price; Francesco Padormo; Joseph V Hajnal; Shaihan J Malik
Journal:  NMR Biomed       Date:  2017-02-14       Impact factor: 4.044

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.