Literature DB >> 25365362

Proton range verification through prompt gamma-ray spectroscopy.

Joost M Verburg1, Joao Seco.   

Abstract

We present an experimental study of a novel method to verify the range of proton therapy beams. Differential cross sections were measured for 15 prompt gamma-ray lines from proton-nuclear interactions with (12)C and (16)O at proton energies up to 150 MeV. These cross sections were used to model discrete prompt gamma-ray emissions along proton pencil-beams. By fitting detected prompt gamma-ray counts to these models, we simultaneously determined the beam range and the oxygen and carbon concentration of the irradiated matter. The performance of the method was assessed in two phantoms with different elemental concentrations, using a small scale prototype detector. Based on five pencil-beams with different ranges delivering 5 × 10(8) protons and without prior knowledge of the elemental composition at the measurement point, the absolute range was determined with a standard deviation of 1.0-1.4 mm. Relative range shifts at the same dose level were detected with a standard deviation of 0.3-0.5 mm. The determined oxygen and carbon concentrations also agreed well with the actual values. These results show that quantitative prompt gamma-ray measurements enable knowledge of nuclear reaction cross sections to be used for precise proton range verification in the presence of tissue with an unknown composition.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25365362     DOI: 10.1088/0031-9155/59/23/7089

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  Feasibility Studies of a New Event Selection Method to Improve Spatial Resolution of Compton Imaging for Medical Applications.

Authors:  E Draeger; S Peterson; D Mackin; H Chen; S Beddar; J C Polf
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2017-05-10

2.  Monitoring proton therapy with PET.

Authors:  H Paganetti; G El Fakhri
Journal:  Br J Radiol       Date:  2015-05-20       Impact factor: 3.039

Review 3.  Image guidance in proton therapy for lung cancer.

Authors:  Miao Zhang; Wei Zou; Boon-Keng Kevin Teo
Journal:  Transl Lung Cancer Res       Date:  2018-04

4.  Acoustic-based proton range verification in heterogeneous tissue: simulation studies.

Authors:  Kevin C Jones; Wei Nie; James C H Chu; Julius V Turian; Alireza Kassaee; Chandra M Sehgal; Stephen Avery
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

Review 5.  Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview.

Authors:  Radhe Mohan; Indra J Das; Clifton C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-10-01       Impact factor: 7.038

Review 6.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

7.  Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: a Theoretical Study.

Authors:  F Hueso-González; T Bortfeld
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-07-23

8.  The effects of Compton camera data acquisition and readout timing on PG imaging for proton range verification.

Authors:  Jerimy C Polf; Paul Maggi; Rajesh Panthi; Stephen Peterson; Dennis Mackin; Sam Beddar
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-02-05

9.  A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy.

Authors:  Fernando Hueso-González; Moritz Rabe; Thomas A Ruggieri; Thomas Bortfeld; Joost M Verburg
Journal:  Phys Med Biol       Date:  2018-09-17       Impact factor: 3.609

10.  Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region.

Authors:  Yunhe Xie; Johannes Petzoldt; Guillaume Janssens; Fionnbarr O'Grady; Lingshu Yin; El Hassane Bentefour; Julien Smeets; Damien Prieels; Robert A Lustig; Alexander Lin; Boon-Keng Teo
Journal:  Br J Radiol       Date:  2020-10-06       Impact factor: 3.039

View more