Literature DB >> 25360355

Comparison of binocular through-focus visual acuity with monovision and a small aperture inlay.

Christina Schwarz1, Silvestre Manzanera1, Pedro M Prieto1, Enrique J Fernández1, Pablo Artal1.   

Abstract

Corneal small aperture inlays provide extended depth of focus as a solution to presbyopia. As this procedure is becoming more popular, it is interesting to compare its performance with traditional approaches, such as monovision. Here, binocular visual acuity was measured as a function of object vergence in three subjects by using a binocular adaptive optics vision analyzer. Visual acuity was measured at two luminance levels (photopic and mesopic) under several optical conditions: 1) natural vision (4 mm pupils, best corrected distance vision), 2) pure-defocus monovision ( + 1.25 D add in the nondominant eye), 3) small aperture monovision (1.6 mm pupil in the nondominant eye), and 4) combined small aperture and defocus monovision (1.6 mm pupil and a + 0.75 D add in the nondominant eye). Visual simulations of a small aperture corneal inlay suggest that the device extends DOF as effectively as traditional monovision in photopic light, in both cases at the cost of binocular summation. However, individual factors, such as aperture centration or sensitivity to mesopic conditions should be considered to assure adequate visual outcomes.

Entities:  

Keywords:  (110.1080) Active or adaptive optics; (330.1400) Vision - binocular and stereopsis; (330.4460) Ophthalmic optics and devices

Year:  2014        PMID: 25360355      PMCID: PMC4206307          DOI: 10.1364/BOE.5.003355

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  29 in total

1.  Effect of induced anisometropia on binocular through-focus contrast sensitivity.

Authors:  R Legras; V Hornain; A Monot; N Chateau
Journal:  Optom Vis Sci       Date:  2001-07       Impact factor: 1.973

2.  Impact of interocular differences in corneal asphericity on binocular summation.

Authors:  José Ramón Jiménez Cuesta; Rosario Gonzalez Anera; Raimundo Jiménez; Carlos Salas
Journal:  Am J Ophthalmol       Date:  2003-03       Impact factor: 5.258

3.  Refractive surgical correction of presbyopia with the AcuFocus small aperture corneal inlay: two-year follow-up.

Authors:  Orang Seyeddain; Wolfgang Riha; Melchior Hohensinn; Gerhard Nix; Alois K Dexl; Günther Grabner
Journal:  J Refract Surg       Date:  2010-04-15       Impact factor: 3.573

4.  Interocular differences in higher-order aberrations on binocular visual performance.

Authors:  José R Jiménez; José J Castro; Raimundo Jiménez; Enrique Hita
Journal:  Optom Vis Sci       Date:  2008-03       Impact factor: 1.973

5.  Binocular adaptive optics visual simulator.

Authors:  Enrique J Fernández; Pedro M Prieto; Pablo Artal
Journal:  Opt Lett       Date:  2009-09-01       Impact factor: 3.776

6.  Ocular dominance and the interocular suppression of blur in monovision.

Authors:  C Schor; L Landsman; P Erickson
Journal:  Am J Optom Physiol Opt       Date:  1987-10

7.  Distance visual acuity and monovision.

Authors:  M Collins; A Goode; B Brown
Journal:  Optom Vis Sci       Date:  1993-09       Impact factor: 1.973

8.  Monocular versus binocular visual acuity.

Authors:  F W Campbell; D G Green
Journal:  Nature       Date:  1965-10-09       Impact factor: 49.962

9.  Reading performance and patient satisfaction after corneal inlay implantation for presbyopia correction: two-year follow-up.

Authors:  Alois K Dexl; Orang Seyeddain; Wolfgang Riha; Theresa Rückl; Alexander Bachernegg; Martin Emesz; Josef Ruckhofer; Günther Grabner
Journal:  J Cataract Refract Surg       Date:  2012-08-22       Impact factor: 3.351

10.  Impact on stereo-acuity of two presbyopia correction approaches: monovision and small aperture inlay.

Authors:  Enrique J Fernández; Christina Schwarz; Pedro M Prieto; Silvestre Manzanera; Pablo Artal
Journal:  Biomed Opt Express       Date:  2013-05-08       Impact factor: 3.732

View more
  10 in total

1.  Temporal integration property of stereopsis after higher-order aberration correction.

Authors:  Jian Kang; Yun Dai; Yudong Zhang
Journal:  Biomed Opt Express       Date:  2015-10-20       Impact factor: 3.732

2.  The role of sensory ocular dominance on through-focus visual performance in monovision presbyopia corrections.

Authors:  Len Zheleznyak; Aixa Alarcon; Kevin C Dieter; Duje Tadin; Geunyoung Yoon
Journal:  J Vis       Date:  2015       Impact factor: 2.240

3.  Optics and neural adaptation jointly limit human stereovision.

Authors:  Cherlyn J Ng; Randolph Blake; Martin S Banks; Duje Tadin; Geunyoung Yoon
Journal:  Proc Natl Acad Sci U S A       Date:  2021-06-08       Impact factor: 11.205

4.  Binocular summation and visual function with induced anisocoria and monovision.

Authors:  José J Castro; Margarita Soler; Carolina Ortiz; José R Jiménez; Rosario G Anera
Journal:  Biomed Opt Express       Date:  2016-09-23       Impact factor: 3.732

Review 5.  Vision science and adaptive optics, the state of the field.

Authors:  Susana Marcos; John S Werner; Stephen A Burns; William H Merigan; Pablo Artal; David A Atchison; Karen M Hampson; Richard Legras; Linda Lundstrom; Geungyoung Yoon; Joseph Carroll; Stacey S Choi; Nathan Doble; Adam M Dubis; Alfredo Dubra; Ann Elsner; Ravi Jonnal; Donald T Miller; Michel Paques; Hannah E Smithson; Laura K Young; Yuhua Zhang; Melanie Campbell; Jennifer Hunter; Andrew Metha; Grazyna Palczewska; Jesse Schallek; Lawrence C Sincich
Journal:  Vision Res       Date:  2017-02-27       Impact factor: 1.886

6.  Pharmacological Treatment of Presbyopia by Novel Binocularly Instilled Eye Drops: A Pilot Study.

Authors:  Antonio Renna; L Felipe Vejarano; Ernesto De la Cruz; Jorge L Alió
Journal:  Ophthalmol Ther       Date:  2016-05-11

7.  Extended depth of focus contact lenses vs. two commercial multifocals: Part 2. Visual performance after 1 week of lens wear.

Authors:  Ravi C Bakaraju; Daniel Tilia; Jennifer Sha; Jennie Diec; Jiyoon Chung; Danny Kho; Shona Delaney; Anna Munro; Varghese Thomas
Journal:  J Optom       Date:  2017-06-12

8.  Optimization of the Light Sword Lens for Presbyopia Correction.

Authors:  Walter Torres-Sepúlveda; Alejandro Mira-Agudelo; John Fredy Barrera-Ramírez; Krzysztof Petelczyc; Andrzej Kolodziejczyk
Journal:  Transl Vis Sci Technol       Date:  2020-02-12       Impact factor: 3.283

9.  Vision with different presbyopia corrections simulated with a portable binocular visual simulator.

Authors:  Aiswaryah Radhakrishnan; Daniel Pascual; Susana Marcos; Carlos Dorronsoro
Journal:  PLoS One       Date:  2019-08-20       Impact factor: 3.240

Review 10.  Bilateral symmetry in vision and influence of ocular surgical procedures on binocular vision: A topical review.

Authors:  Samuel Arba Mosquera; Shwetabh Verma
Journal:  J Optom       Date:  2016-03-16
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.