Literature DB >> 25359183

Doppler ultrasound compared with electrocardiogram and pulse oximetry cardiac triggering: A pilot study.

Fabian Kording1, Bjoern Schoennagel1, Gunnar Lund1, Friedrich Ueberle2, Caroline Jung1, Gerhard Adam1, Jin Yamamura1.   

Abstract

PURPOSE: Accurate triggering of the cardiac cycle is mandatory for optimal image acquisition and thus diagnostic quality in cardiac magnetic resonance imaging. The purpose of this work was to evaluate Doppler ultrasound as an alternative trigger method in cardiac MRI.
METHODS: Steady-state free precession (SSFP) 2D cine CMR was performed in 11 healthy subjects at 1.5T. Doppler ultrasound (DUS), electrocardiogram (ECG) and pulse oximetry (POX) were used for cardiac triggering. DUS peak detection was verified in comparison to ECG. Quantitative analysis of image quality of each gating method was determined by calculating endocardial border sharpness (EBS) and left ventricular (LV) function parameters and compared with ECG.
RESULTS: Mean difference between DUS and ECG in detected RR intervals was 0.04 ± 63 ms (r = 0.96). Trigger jitter was not different between ECG and DUS (P = 0.15) but significant different between ECG and POX (P = 0.01). EBS was similar between each method (3.1 ± 0.2 / 2.6 ± 0.2 / 2.9 ± 0.2 pixel). Mean differences in stroke volume were not significantly different with -1 ± 7 mL (ECG/DUS, P = 0.9) and 2 ± 10 mL (ECG/POX, P = 0.8).
CONCLUSION: Cine cardiac MRI using DUS was successfully demonstrated. DUS triggering is an alternative method for cardiac MRI and may be applied in a clinical setting.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  Doppler ultrasound; cardiac-gated imaging techniques; cine magnetic resonance imaging; computer-assisted image processing; electrocardiogram; oximetry

Mesh:

Year:  2014        PMID: 25359183     DOI: 10.1002/mrm.25502

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Model-based estimation of QT intervals of mouse fetal electrocardiogram.

Authors:  Namareq Widatalla; Kiyoe Funamoto; Motoyoshi Kawataki; Chihiro Yoshida; Kenichi Funamoto; Masatoshi Saito; Yoshiyuki Kasahara; Ahsan Khandoker; Yoshitaka Kimura
Journal:  Biomed Eng Online       Date:  2022-06-29       Impact factor: 3.903

2.  Ultrasound-based sensors for respiratory motion assessment in multimodality PET imaging.

Authors:  Bruno Madore; Gabriela Belsley; Cheng-Chieh Cheng; Frank Preiswerk; Marie Foley Kijewski; Pei-Hsin Wu; Laurel B Martell; Josien P W Pluim; Marcelo Di Carli; Stephen C Moore
Journal:  Phys Med Biol       Date:  2022-01-19       Impact factor: 4.174

3.  Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach.

Authors:  Tobias Rutz; Davide Piccini; Simone Coppo; Jerome Chaptinel; Giulia Ginami; Gabriella Vincenti; Matthias Stuber; Juerg Schwitter
Journal:  Int J Cardiovasc Imaging       Date:  2016-08-22       Impact factor: 2.357

4.  Single breath-hold 3D measurement of left atrial volume using compressed sensing cardiovascular magnetic resonance and a non-model-based reconstruction approach.

Authors:  Orestis Vardoulis; Pierre Monney; Amit Bermano; Amir Vaxman; Craig Gotsman; Janine Schwitter; Matthias Stuber; Nikolaos Stergiopulos; Juerg Schwitter
Journal:  J Cardiovasc Magn Reson       Date:  2015-06-11       Impact factor: 5.364

5.  Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

Authors:  Janusz Jezewski; Janusz Wrobel; Adam Matonia; Krzysztof Horoba; Radek Martinek; Tomasz Kupka; Michal Jezewski
Journal:  Front Physiol       Date:  2017-05-16       Impact factor: 4.566

6.  Motion compensated cine CMR of the fetal heart using radial undersampling and compressed sensing.

Authors:  Christopher W Roy; Mike Seed; John C Kingdom; Christopher K Macgowan
Journal:  J Cardiovasc Magn Reson       Date:  2017-03-20       Impact factor: 5.364

7.  Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating.

Authors:  Fabian Kording; Jin Yamamura; Manuela Tavares de Sousa; Christian Ruprecht; Erik Hedström; Anthony H Aletras; P Ellen Grant; Andrew J Powell; Kai Fehrs; Gerhard Adam; Hendrik Kooijman; Bjoern P Schoennagel
Journal:  J Cardiovasc Magn Reson       Date:  2018-03-12       Impact factor: 5.364

8.  Evaluation of a Portable Doppler Ultrasound Gating Device for Fetal Cardiac MR Imaging: Initial Results at 1.5T and 3T.

Authors:  Fabian Kording; Bjoern P Schoennagel; Manuela Tavares de Sousa; Kai Fehrs; Gerhard Adam; Jin Yamamura; Christian Ruprecht
Journal:  Magn Reson Med Sci       Date:  2018-02-21       Impact factor: 2.471

9.  Feasibility of detecting myocardial infarction in the sheep fetus using late gadolinium enhancement CMR imaging.

Authors:  An Qi Duan; Mitchell C Lock; Sunthara Rajan Perumal; Jack R Darby; Jia Yin Soo; Joseph B Selvanayagam; Christopher K Macgowan; Mike Seed; Janna L Morrison
Journal:  J Cardiovasc Magn Reson       Date:  2017-09-13       Impact factor: 5.364

10.  Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study.

Authors:  Fabian Kording; Jin Yamamura; Gunnar Lund; Friedrich Ueberle; Caroline Jung; Gerhard Adam; Bjoern Philip Schoennagel
Journal:  Magn Reson Med Sci       Date:  2016-03-21       Impact factor: 2.471

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.