Use of an expanded lateral hip view to assist guidewire placement during dynamic hip screw fixation.

A G Marsh1, A Ker.   

Abstract

Mesh:

Year:  2014        PMID: 25350200      PMCID: PMC4474119          DOI: 10.1308/rcsann.2014.96.8.630b

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


× No keyword cloud information.
  2 in total

1.  Sliding hip screws: modes of failure.

Authors:  A H Simpson; K Varty; C A Dodd
Journal:  Injury       Date:  1989-07       Impact factor: 2.586

2.  The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip.

Authors:  M R Baumgaertner; S L Curtin; D M Lindskog; J M Keggi
Journal:  J Bone Joint Surg Am       Date:  1995-07       Impact factor: 5.284