Literature DB >> 25348548

Diagnostic performance of bone scintigraphy analyzed by three artificial neural network systems.

Shoichi Kikushima1, Noboru Hanawa, Fumio Kotake.   

Abstract

OBJECTIVE: The accuracy of bone scintigraphy analyzed by computer-assisted diagnosis (CAD) software involving multiple artificial neural network (ANN) systems has not been well established.
METHODS: We conducted a retrospective study to examine the accuracy of bone scintigraphy analyzed by CAD software, BONENAVI(®) version 2 (BN2; FUJIFILM RI Pharma Co., Ltd.), in patients with suspected bone metastases. In 399 patients, bone metastases were analyzed by means of the BN2 focused on balance of sensitivity and specificity ANN system (BN2-B), focused on specificity-ANN system (BN2-Sp), and focused on sensitivity-ANN system (BN2-Sen). The ANN presented an output between 0 and 1 for each patient. A cutoff value of 0.5 was chosen to provide BN2 with the binary classification of "bone metastasis" or "no bone metastasis". The area under the receiver operating characteristic curve (AUC) was used to evaluate diagnostic accuracy.
RESULTS: A total of 18 % of male patients (36/196) and 12 % of female patients (24/203) had bone metastases. BN2-Sp and BN2-Sen were similar to BN2-B in the ability to identify patients who had bone metastases; the AUC values were 0.87 [95 % confidence interval (CI) 0.79-0.95], 0.92 (95 % CI 0.85-0.97), and 0.90 (95 % CI 0.83-0.97), respectively, in male patients. In female patients, the AUC values were 0.81 (95 % CI 0.71-0.91), 0.85 (95 % CI 0.78-0.93), and 0.81 (95 % CI 0.71-0.92), respectively. A total of 65.4 % of patients were classified as concordance of "bone metastases" (17.8 %) or "no bone metastases" (47.6 %), and 34.6 % were classified as mismatch. In the concordance group, BN2-B revealed an AUC of 0.94 (95 % CI 0.88-0.99), with a sensitivity of 94 % (95 % CI 79-98 %) and a specificity of 88 % (95 % CI 79-93 %) in 120 male patients and an AUC of 0.89 (95 % CI 0.78-1.00), with a sensitivity of 86 % (95 % CI 60-96 %) and a specificity of 85 % (95 % CI 78-90 %) in 141 female patients.
CONCLUSIONS: Bone scintigraphy analyzed by BN2-B accurately identifies the presence of bone metastases in patients with concordance using three ANN systems, comprising 65 % of the patients we studied.

Entities:  

Mesh:

Year:  2014        PMID: 25348548     DOI: 10.1007/s12149-014-0919-5

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  3 in total

1.  Computer-assisted quantitative evaluation of bisphosphonate treatment for Paget's disease of bone using the bone scan index.

Authors:  Satoshi Nagano; Shunsuke Nakamura; Hirofumi Shimada; Masahiro Yokouchi; Takao Setoguchi; Yasuhiro Ishidou; Hiromi Sasaki; Setsuro Komiya
Journal:  Exp Ther Med       Date:  2016-11-14       Impact factor: 2.447

Review 2.  Radiomics Analysis of [18F]FDG PET/CT Thyroid Incidentalomas: How Can It Improve Patients' Clinical Management? A Systematic Review from the Literature.

Authors:  Mirela Gherghe; Alexandra Maria Lazar; Mario-Demian Mutuleanu; Adina Elena Stanciu; Sorina Martin
Journal:  Diagnostics (Basel)       Date:  2022-02-12

3.  Novel diagnostic model for bone metastases in renal cell carcinoma patients based on bone scintigraphy analyzed by computer-aided diagnosis software and bone turnover markers.

Authors:  Takeshi Ujike; Motohide Uemura; Taigo Kato; Koji Hatano; Atsunari Kawashima; Akira Nagahara; Kazutoshi Fujita; Ryoichi Imamura; Norio Nonomura
Journal:  Int J Clin Oncol       Date:  2022-02-04       Impact factor: 3.402

  3 in total