Literature DB >> 25348474

Improved image quality at 256-slice coronary CT angiography in patients with a high heart rate and coronary artery disease: comparison with 64-slice CT imaging.

Seitaro Oda1, Kazuhiro Katahira2, Daisuke Utsunomiya3, Hiroko Takaoka2, Keiichi Honda2, Katsuo Noda4, Shuichi Oshima4, Hideaki Yuki3, Tomohiro Namimoto3, Yasuyuki Yamashita3.   

Abstract

BACKGROUND: The 256-slice computed tomography (CT) scanners with wider detector coverage and faster gantry rotation speed are now available. The performance of scanners that feature a rotation speed of 270 ms at coronary CT angiography (CCTA) has not been evaluated in patients with a higher heart rate.
PURPOSE: To evaluate the image quality of 256-slice CT with faster gantry rotation speed in patients undergoing CCTA.
MATERIAL AND METHODS: We enrolled 886 patients; 357(40.3%) underwent study on a 64-slice CT at a rotation speed of 420 ms, the other 529 (59.7%) were examined using a 256-slice CT scanner at 270 ms. Two observers judged the image quality of 2658 imaged coronary arteries on a 4-point scale.
RESULTS: The mean image quality score was significantly higher for the 256 - than the 64-slice CT scans (3.94 ± 0.28 vs. 3.73 ± 0.61; P < 0.01). There was no significant difference in the image quality scores between 64 - and 256-slice scans in patients whose heart rate (HR) was <60 bpm. However, in patients whose HR exceeded 60 bpm these scores were significantly higher for 256-slice CT images (P < 0.01).
CONCLUSION: CCTA performed on the 256-slice CT scanner yielded significantly better image quality in patients with an HR exceeding 60 bpm. © The Foundation Acta Radiologica 2014.

Entities:  

Keywords:  256-slice CT; Coronary CT angiography; computed tomography (CT); heart rate; image quality; rotation speed

Mesh:

Substances:

Year:  2014        PMID: 25348474     DOI: 10.1177/0284185114555152

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  5 in total

1.  CT compared to MRI for functional evaluation of the right ventricle: a systematic review and meta-analysis.

Authors:  Hang Fu; Xuedong Wang; Kaiyue Diao; Shan Huang; Hui Liu; Yue Gao; Qin Zhao; Zhi-Gang Yang; Ying-Kun Guo
Journal:  Eur Radiol       Date:  2019-05-27       Impact factor: 5.315

2.  256-Slice coronary computed tomographic angiography in patients with atrial fibrillation: optimal reconstruction phase and image quality.

Authors:  Seitaro Oda; Keiichi Honda; Akira Yoshimura; Kazuhiro Katahira; Katsuo Noda; Shuichi Oshima; Hideaki Yuki; Masafumi Kidoh; Daisuke Utsunomiya; Takeshi Nakaura; Tomohiro Namimoto; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2015-05-21       Impact factor: 5.315

3.  Clinical evaluation of new automatic coronary-specific best cardiac phase selection algorithm for single-beat coronary CT angiography.

Authors:  Hui Wang; Lei Xu; Zhanming Fan; Junfu Liang; Zixu Yan; Zhonghua Sun
Journal:  PLoS One       Date:  2017-02-23       Impact factor: 3.240

4.  Diagnosis of diaphragm injuries using modern 256-slice CT scanners: too early to abandon operative exploration.

Authors:  Rindi Uhlich; Jeffrey David Kerby; Patrick Bosarge; Parker Hu
Journal:  Trauma Surg Acute Care Open       Date:  2018-11-26

Review 5.  Low-Dose Radiation Advances in Coronary Computed Tomography Angiography in the Diagnosis of Coronary Artery Disease.

Authors:  Caryl E Richards; Daniel R Obaid
Journal:  Curr Cardiol Rev       Date:  2019
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.