Literature DB >> 25343709

Assessment of the radiological safety of a Genoray portable dental X-ray unit.

S M Hosseini Pooya1, L Hafezi, F Manafi, A R Talaeipour.   

Abstract

OBJECTIVES: The portable dental radiographic systems are generally used in emergency situations (e.g. during natural disasters) for disabled/aged patients and in patient rooms. This study assesses the output exposure of a portable dental radiographic system measured using thermoluminescent dosemeters (TLDs).
METHODS: Occupational exposure of the operator was determined when the portable dental unit was used for mandibular and maxillary teeth exposure.
RESULTS: The doses of some critical organs of an operator were measured using TLDs implanted within the Rando phantom.
CONCLUSIONS: Considering the annual organ dose limits, the eye lens dose limit is the main factor determining the frequency of system application.

Entities:  

Keywords:  TLD; X-ray; absorbed dose; dental exposure; occupational exposure; portable dental exposure

Mesh:

Year:  2014        PMID: 25343709      PMCID: PMC4614165          DOI: 10.1259/dmfr.20140255

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  4 in total

1.  Calculation of patient effective dose and scattered dose for dental mobile fluoroscopic equipment: application of the Monte Carlo simulation.

Authors:  Boram Lee; Jungseok Lee; Sangwon Kang; Hyelim Cho; Gwisoon Shin; Jeong-Woo Lee; Jonghak Choi
Journal:  Radiat Prot Dosimetry       Date:  2012-05-28       Impact factor: 0.972

2.  Operator exposure to scatter radiation from a portable hand-held dental radiation emitting device (Aribex NOMAD) while making 915 intraoral dental radiographs.

Authors:  Robert A Danforth; Edward E Herschaft; John A Leonowich
Journal:  J Forensic Sci       Date:  2009-01-29       Impact factor: 1.832

Review 3.  ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context.

Authors:  F A Stewart; A V Akleyev; M Hauer-Jensen; J H Hendry; N J Kleiman; T J Macvittie; B M Aleman; A B Edgar; K Mabuchi; C R Muirhead; R E Shore; W H Wallace
Journal:  Ann ICRP       Date:  2012-02

4.  Radiation exposure with the NOMAD portable X-ray system.

Authors:  A D Goren; M Bonvento; J Biernacki; D C Colosi
Journal:  Dentomaxillofac Radiol       Date:  2008-02       Impact factor: 2.419

  4 in total
  1 in total

1.  Evaluation of stray radiation to the operator for five hand-held dental X-ray devices.

Authors:  Richard Smith; Richard Tremblay; Graeme M Wardlaw
Journal:  Dentomaxillofac Radiol       Date:  2019-02-12       Impact factor: 2.419