The Icare-Pro Rebound Tonometer Versus the Hand-held Applanation Tonometer in Congenital Glaucoma.

Lara Borrego Sanz1, Laura Morales-Fernandez, Jose M Martínez de-la-Casa, Federico Sáenz-Francés, Manuel Fuentes, Julián García-Feijóo.   

Abstract

PURPOSE: To compare intraocular pressure (IOP) measurements obtained using the new rebound tonometer Icare-Pro and the hand-held version of Goldmann Applanation Tonometer (Perkins tonometer) in children with primary congenital glaucoma (PCG) under general anesthesia.
MATERIALS AND METHODS: Using both tonometers, 3 IOP measurements were prospectively determined in 1 single session. Icare-Pro was always used first, and then Perkins. All measurements were recruited in 50 eyes of 50 patients with PCG under general anesthesia. Central corneal thickness, anterior chamber depth, and axial length were also measured in each patient. Data were compared by determining interclass correlation coefficient for each tonometer and representing the differences detected as Bland-Altman plots.
RESULTS: Good linear correlation was observed between IOP readings obtained using the Perkins and Icare-Pro (r=0.75, P<0.001), although the Icare-Pro readings were slightly higher (mean IOP difference 0.42 ± 3.69 mm Hg, P=0.41). A Bland-Altman plot revealed the 95% limits of agreement between the 2 methods: 7.7 to -6.8 mm Hg (slope=0.109, P=0.32). Intraclass correlation coefficient was 0.74 (95% confidence interval, 0.59-0.84) showing good agreement. For both tonometers, no correlation was detected between IOP measurements and central corneal thickness and axial length, but positive relation was found with anterior chamber depth.
CONCLUSIONS: IOP measurements determined using the new Icare-Pro rebound tonometer showed good correlation with those obtained using the hand-held Perkins applanation tonometer in children with PCG under general anesthesia.

Entities:  

Mesh:

Year:  2016        PMID: 25333612     DOI: 10.1097/IJG.0000000000000177

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  7 in total

1.  Critical pathway for primary open angle glaucoma diagnosis.

Authors:  Alejandro R Allocco; Julia A Ponce; Maria J Riera; Mauricio G Magurno
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

2.  A comparison of Icare PRO and Perkins tonometers in anesthetized children.

Authors:  Massimiliano Serafino; Edoardo Villani; Andrea Lembo; Giovanni Rabbiolo; Claudia Specchia; Rupal H Trivedi; Paolo Nucci
Journal:  Int Ophthalmol       Date:  2019-07-16       Impact factor: 2.031

3.  Intraocular Pressure Measurement in Childhood Glaucoma under Standardized General Anaesthesia: The Prospective EyeBIS Study.

Authors:  Alicja Strzalkowska; Nina Pirlich; Julia V Stingl; Alexander K Schuster; Jasmin Rezapour; Felix M Wagner; Justus Buse; Esther M Hoffmann
Journal:  J Clin Med       Date:  2022-05-18       Impact factor: 4.964

4.  Automatic method of analysis and measurement of additional parameters of corneal deformation in the Corvis tonometer.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2014-11-19       Impact factor: 2.819

5.  A Comparison of Rebound to Indentation Tonometry in Supine Sedated Children with Glaucoma.

Authors:  Dora H AlHarkan; Fatemah T Al-Shamlan; Deepak P Edward; Arif O Khan
Journal:  Middle East Afr J Ophthalmol       Date:  2016 Apr-Jun

6.  Roles of CYP2C19 Gene Polymorphisms in Susceptibility to POAG and Individual Differences in Drug Treatment Response.

Authors:  Xiang-Long Liu; Qiu-Ju Jia; Li-Na Wang; Zong-Ming Liu; Hai Liu; Xuan-Chu Duan; Xue-Man Lyu
Journal:  Med Sci Monit       Date:  2016-01-29

7.  Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer.

Authors:  Feng Gao; Xu Liu; Qing Zhao; Yingzhe Pan
Journal:  Exp Ther Med       Date:  2017-02-24       Impact factor: 2.447