INTRODUCTION: We conducted this pilot randomized clinical trial to determine the feasibility of a large clinical trial aimed at testing whether early use of catheter ablation of ventricular tachycardia (VT) is superior to antiarrhythmic medications at reducing mortality. METHODS AND RESULTS:Patients were enrolled at 4 sites if they had ischemic heart disease, an implantable cardioverter defibrillator (ICD), and received ≥1ICD shock or ≥3 antitachycardia pacing therapies for VT. Patients were randomized to 2 arms: (1) antiarrhythmic medication (n = 14) and (2) catheter ablation (n = 13); patients were followed at 3 and 6 months. Endpoints included recurrent VT, time to first ICD therapy for VT, and death. Of 243 screened patients, 27 were enrolled. Main reasons for screen failures were: (1) patient was already on an antiarrhythmic medication (88 [41%]), (2) VT due to a reversible cause (23 [11%]), and (3) incessant VT (20 [9%]). Fourteen patients had recurrent VT, 8 (62%) in the ablation arm and 6 (43%) in the antiarrhythmic medication arm. Median time to recurrent VT was 75 days (25th, 75th: 51, 89) in the ablation arm and 57 days (30, 145) in the antiarrhythmic arm. Four patients died, 2 in each arm. CONCLUSION: This clinical trial shows that most patients in clinical practice have already failed antiarrhythmic drug therapy before catheter ablation is considered, and the VT recurrence rates and death in these patients are high. For a large clinical trial to be feasible, factors limiting early consideration of catheter ablation need to be identified and addressed.
RCT Entities:
INTRODUCTION: We conducted this pilot randomized clinical trial to determine the feasibility of a large clinical trial aimed at testing whether early use of catheter ablation of ventricular tachycardia (VT) is superior to antiarrhythmic medications at reducing mortality. METHODS AND RESULTS:Patients were enrolled at 4 sites if they had ischemic heart disease, an implantable cardioverter defibrillator (ICD), and received ≥1 ICD shock or ≥3 antitachycardia pacing therapies for VT. Patients were randomized to 2 arms: (1) antiarrhythmic medication (n = 14) and (2) catheter ablation (n = 13); patients were followed at 3 and 6 months. Endpoints included recurrent VT, time to first ICD therapy for VT, and death. Of 243 screened patients, 27 were enrolled. Main reasons for screen failures were: (1) patient was already on an antiarrhythmic medication (88 [41%]), (2) VT due to a reversible cause (23 [11%]), and (3) incessant VT (20 [9%]). Fourteen patients had recurrent VT, 8 (62%) in the ablation arm and 6 (43%) in the antiarrhythmic medication arm. Median time to recurrent VT was 75 days (25th, 75th: 51, 89) in the ablation arm and 57 days (30, 145) in the antiarrhythmic arm. Four patients died, 2 in each arm. CONCLUSION: This clinical trial shows that most patients in clinical practice have already failed antiarrhythmic drug therapy before catheter ablation is considered, and the VT recurrence rates and death in these patients are high. For a large clinical trial to be feasible, factors limiting early consideration of catheter ablation need to be identified and addressed.
Authors: Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld Journal: J Interv Card Electrophysiol Date: 2020-10 Impact factor: 1.900
Authors: Sean D Pokorney; Daniel J Friedman; Hugh Calkins; David J Callans; Emile G Daoud; Paolo Della-Bella; Kevin P Jackson; Kalyanam Shivkumar; Samir Saba; John Sapp; William G Stevenson; Sana M Al-Khatib Journal: Heart Rhythm Date: 2016-04-02 Impact factor: 6.343
Authors: Divyang Patel; Vic Hasselblad; Kevin P Jackson; Sean D Pokorney; James P Daubert; Sana M Al-Khatib Journal: J Interv Card Electrophysiol Date: 2015-12-22 Impact factor: 1.900
Authors: Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Sáenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld Journal: Europace Date: 2019-08-01 Impact factor: 5.214