Literature DB >> 25326533

A longitudinal comparison of hemodynamics and intraluminal thrombus deposition in abdominal aortic aneurysms.

Amirhossein Arzani1, Ga-Young Suh2, Ronald L Dalman2, Shawn C Shadden3.   

Abstract

Abdominal aortic aneurysm (AAA) is often accompanied by in traluminal thrombus (ILT), which complicates AAA progression and risk of rupture. Patient-specific computational fluid dynamics modeling of 10 small human AAA was performed to investigate relations between hemodynamics and ILT progression. The patients were imaged using magnetic resonance twice in a 2- to 3-yr interval. Wall content data were obtained by a planar T1-weighted fast spin echo black-blood scan, which enabled quantification of thrombus thickness at midaneurysm location during baseline and followup. Computational simulations with patient-specific geometry and boundary conditions were performed to quantify the hemodynamic parameters of time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and mean exposure time at baseline. Spatially resolved quantifications of the change in ILT thickness were compared with the different hemodynamic parameters. Regions of low OSI had the strongest correlation with ILT growth and demonstrated a statistically significant correlation coefficient. Prominent regions of high OSI (>0.4) and low TAWSS (<1 dyn/cm(2)) did not appear to coincide with locations of thrombus deposition.
Copyright © 2014 the American Physiological Society.

Entities:  

Keywords:  computational fluid dynamics; hemodynamics; oscillatory shear index; thrombosis; wall shear stress

Mesh:

Year:  2014        PMID: 25326533      PMCID: PMC4269702          DOI: 10.1152/ajpheart.00461.2014

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  43 in total

1.  Flow behaviour in an asymmetric compliant experimental model for abdominal aortic aneurysm.

Authors:  Valerie Deplano; Yannick Knapp; Eric Bertrand; Emmanuel Gaillard
Journal:  J Biomech       Date:  2007-01-26       Impact factor: 2.712

Review 2.  An image-based modeling framework for patient-specific computational hemodynamics.

Authors:  Luca Antiga; Marina Piccinelli; Lorenzo Botti; Bogdan Ene-Iordache; Andrea Remuzzi; David A Steinman
Journal:  Med Biol Eng Comput       Date:  2008-11-11       Impact factor: 2.602

3.  Characterization of coherent structures in the cardiovascular system.

Authors:  Shawn C Shadden; Charles A Taylor
Journal:  Ann Biomed Eng       Date:  2008-04-25       Impact factor: 3.934

Review 4.  Review of prevalence and outcome of vascular disease in patients with diabetes mellitus.

Authors:  J S Weiss; B E Sumpio
Journal:  Eur J Vasc Endovasc Surg       Date:  2005-10-03       Impact factor: 7.069

Review 5.  Heart disease and stroke statistics--2013 update: a report from the American Heart Association.

Authors:  Alan S Go; Dariush Mozaffarian; Véronique L Roger; Emelia J Benjamin; Jarett D Berry; William B Borden; Dawn M Bravata; Shifan Dai; Earl S Ford; Caroline S Fox; Sheila Franco; Heather J Fullerton; Cathleen Gillespie; Susan M Hailpern; John A Heit; Virginia J Howard; Mark D Huffman; Brett M Kissela; Steven J Kittner; Daniel T Lackland; Judith H Lichtman; Lynda D Lisabeth; David Magid; Gregory M Marcus; Ariane Marelli; David B Matchar; Darren K McGuire; Emile R Mohler; Claudia S Moy; Michael E Mussolino; Graham Nichol; Nina P Paynter; Pamela J Schreiner; Paul D Sorlie; Joel Stein; Tanya N Turan; Salim S Virani; Nathan D Wong; Daniel Woo; Melanie B Turner
Journal:  Circulation       Date:  2012-12-12       Impact factor: 29.690

6.  A relation between near-wall particle-hemodynamics and onset of thrombus formation in abdominal aortic aneurysms.

Authors:  C Basciano; C Kleinstreuer; S Hyun; E A Finol
Journal:  Ann Biomed Eng       Date:  2011-03-04       Impact factor: 3.934

7.  Growth of thrombus may be a better predictor of rupture than diameter in patients with abdominal aortic aneurysms.

Authors:  J Stenbaek; B Kalin; J Swedenborg
Journal:  Eur J Vasc Endovasc Surg       Date:  2000-11       Impact factor: 7.069

Review 8.  Biochemomechanics of intraluminal thrombus in abdominal aortic aneurysms.

Authors:  J S Wilson; L Virag; P Di Achille; I Karsaj; J D Humphrey
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

9.  Ultrasonic evaluation of abdominal aortic thrombus.

Authors:  L P Harter; B H Gross; P W Callen; R A Barth
Journal:  J Ultrasound Med       Date:  1982-10       Impact factor: 2.153

10.  Intraluminal thrombus and risk of rupture in patient specific abdominal aortic aneurysm - FSI modelling.

Authors:  Danny Bluestein; Kris Dumont; Matthieu De Beule; John Ricotta; Paul Impellizzeri; Benedict Verhegghe; Pascal Verdonck
Journal:  Comput Methods Biomech Biomed Engin       Date:  2009-02       Impact factor: 1.763

View more
  27 in total

1.  Association of Intraluminal Thrombus, Hemodynamic Forces, and Abdominal Aortic Aneurysm Expansion Using Longitudinal CT Images.

Authors:  Byron A Zambrano; Hamidreza Gharahi; ChaeYoung Lim; Farhad A Jaberi; Jongeun Choi; Whal Lee; Seungik Baek
Journal:  Ann Biomed Eng       Date:  2015-10-01       Impact factor: 3.934

2.  A reduced-dimensional model for near-wall transport in cardiovascular flows.

Authors:  Kirk B Hansen; Shawn C Shadden
Journal:  Biomech Model Mechanobiol       Date:  2015-08-23

3.  Characterizations and Correlations of Wall Shear Stress in Aneurysmal Flow.

Authors:  Amirhossein Arzani; Shawn C Shadden
Journal:  J Biomech Eng       Date:  2016-01       Impact factor: 2.097

4.  A robust approach for exploring hemodynamics and thrombus growth associations in abdominal aortic aneurysms.

Authors:  Konstantinos Tzirakis; Yiannis Kamarianakis; Eleni Metaxa; Nikolaos Kontopodis; Christos V Ioannou; Yannis Papaharilaou
Journal:  Med Biol Eng Comput       Date:  2017-01-02       Impact factor: 2.602

5.  Mechanical platelet activation potential in abdominal aortic aneurysms.

Authors:  Kirk B Hansen; Amirhossein Arzani; Shawn C Shadden
Journal:  J Biomech Eng       Date:  2015-02-05       Impact factor: 2.097

6.  Three-dimensional extent of flow stagnation in transcatheter heart valves.

Authors:  Vrishank Raghav; Chris Clifford; Prem Midha; Ikechukwu Okafor; Brian Thurow; Ajit Yoganathan
Journal:  J R Soc Interface       Date:  2019-05-31       Impact factor: 4.118

7.  A Distributed Lumped Parameter Model of Blood Flow.

Authors:  Mehran Mirramezani; Shawn C Shadden
Journal:  Ann Biomed Eng       Date:  2020-07-01       Impact factor: 3.934

8.  A Re-Engineered Software Interface and Workflow for the Open-Source SimVascular Cardiovascular Modeling Package.

Authors:  Hongzhi Lan; Adam Updegrove; Nathan M Wilson; Gabriel D Maher; Shawn C Shadden; Alison L Marsden
Journal:  J Biomech Eng       Date:  2018-02-01       Impact factor: 2.097

9.  Evaluation of the distribution and progression of intraluminal thrombus in abdominal aortic aneurysms using high-resolution MRI.

Authors:  Chengcheng Zhu; Joseph R Leach; Bing Tian; Lizhen Cao; Zhaoying Wen; Yan Wang; Xinke Liu; Qi Liu; Jianping Lu; David Saloner; Michael D Hope
Journal:  J Magn Reson Imaging       Date:  2019-01-29       Impact factor: 4.813

10.  Hemodynamics-driven deposition of intraluminal thrombus in abdominal aortic aneurysms.

Authors:  P Di Achille; G Tellides; J D Humphrey
Journal:  Int J Numer Method Biomed Eng       Date:  2016-10-07       Impact factor: 2.747

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.