Jared H Cooper1, David L Johnson2, Margaret L Phillips1.
Abstract
PURPOSE: To assess the relative efficacy of three types of controls in reducing respirable silica exposure during artificial stone countertop cutting with a handheld circular saw. APPROACH: A handheld worm drive circular saw equipped with a diamond segmented blade was fitted with water supply to wet the blade as is typical. The normal wetted-blade condition was compared to (i) wetted-blade plus 'water curtain' spray and (ii) wetted-blade plus local exhaust ventilation (LEV). Four replicate 30-min trials of 6-mm deep, 3-mm wide cuts in artificial quartz countertop stone were conducted at each condition in a 24-m(3) unventilated tent. One dry cutting trial was also conducted for comparison. Respirable cyclone breathing zone samples were collected on the saw operator and analyzed gravimetrically for respirable mass and by X-ray diffraction for respirable quartz mass.Entities:
Keywords: countertop cutting; engineering controls; respirable silica
Mesh:
Substances:
Year: 2014 PMID: 25326187 PMCID: PMC4290629 DOI: 10.1093/annhyg/meu083
Source DB: PubMed Journal: Ann Occup Hyg ISSN: 0003-4878
1A secondary water flow provided a fan-shaped water curtain sprayed normal to the path of the ejected stone dust. The secondary flow could be shut off during LEV and wetted-blade-only trials. The LEV cowl was attached only during LEV trials.
Respirable dust concentrations (mg m−3) averaged over nominal 30-min sampling period
| Replicate | Wetted blade only | Wetted blade + water curtain | Wetted blade + LEV | Dry |
|---|---|---|---|---|
| 1 | 7.511 | 5.116 | 0.689a | 69.60 |
| 2 | 5.025 | 1.814a | 0.321a | |
| 3 | 3.654 | 5.965 | 0.201a | |
| 4 | 3.546 | 2.357 | 1.204b | |
| Mean | 4.934 | 3.813 | 0.604 | |
| SEM | 0.923 | 1.018 | 0.225 |
aMeasured mass from which this concentration was calculated was < LOD and LOQ.
bMeasured mass from which this concentration was calculated was < LOQ.
Respirable silica dust concentrations (mg m−3) averaged over nominal 30-min sampling period
| Replicate | Wetted blade only | Wetted blade + water curtain | Wetted blade + LEV | Dry |
|---|---|---|---|---|
| 1 | 4.846 | 2.944 | NDa | 44.37 |
| 2 | 2.563 | 0.920b | 0.139b | |
| 3 | 1.874 | 3.405 | 0.201b | |
| 4 | 2.209 | 1.373 | 0.669 | |
| Mean | 4.934 | 3.813 | 0.604 | |
| SEM | 0.923 | 1.018 | 0.225 |
ND, not detected.
aMeasured silica mass from which this concentration was calculated was < LOD.
bMeasured silica mass from which this concentration was calculated was < LOQ.