Literature DB >> 25321720

Performance of megahertz amplified optical time-stretch optical coherence tomography (AOT-OCT).

Jingjiang Xu, Xiaoming Wei, Luoqin Yu, Chi Zhang, Jianbing Xu, K K Y Wong, Kevin K Tsia.   

Abstract

Enabled by the ultrahigh-speed all-optical wavelength-swept mechanism and broadband optical amplification, amplified optical time-stretch optical coherence tomography (AOT-OCT) has recently been demonstrated as a practical alternative to achieve ultrafast A-scan rate of multi-MHz in OCT. With the aim of identifying the optimal scenarios for MHz operation in AOT-OCT, we here present a theoretical framework to evaluate its performance metric. In particular, the analysis discusses the unique features of AOT-OCT, such as its superior coherence length, and the relationship between the optical gain and the A-scan rate. More importantly, we evaluate the sensitivity of AOT-OCT in the MHz regime under the influence of the amplifier noise. Notably, the model shows that AOT-OCT is particularly promising when operated at the A-scan rate well beyond multi-MHz--not trivially achievable by any existing swept-source OCT platform. A sensitivity beyond 90 dB, close to the shot-noise limit, can be maintained in the range of 2 - 10 MHz with an optical net gain of ~10 dB. Experimental measurement also shows excellent agreement with the theoretical prediction. While distributed fiber Raman amplification is mainly considered in this paper, the theoretical model is generally applicable to any type of amplification schemes. As a result, our analysis serves as a useful tool for further optimization of AOT-OCT system--as a practical alternative to enable MHz OCT operation.

Entities:  

Mesh:

Year:  2014        PMID: 25321720     DOI: 10.1364/OE.22.022498

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  4 in total

1.  28 MHz swept source at 1.0 μm for ultrafast quantitative phase imaging.

Authors:  Xiaoming Wei; Andy K S Lau; Yiqing Xu; Kevin K Tsia; Kenneth K Y Wong
Journal:  Biomed Opt Express       Date:  2015-09-08       Impact factor: 3.732

2.  High-performance multi-megahertz optical coherence tomography based on amplified optical time-stretch.

Authors:  Jingjiang Xu; Xiaoming Wei; Luoqin Yu; Chi Zhang; Jianbing Xu; K K Y Wong; Kevin K Tsia
Journal:  Biomed Opt Express       Date:  2015-03-18       Impact factor: 3.732

Review 3.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

4.  Improved Resolution Optical Time Stretch Imaging Based on High Efficiency In-Fiber Diffraction.

Authors:  Guoqing Wang; Zhijun Yan; Lei Yang; Lin Zhang; Chao Wang
Journal:  Sci Rep       Date:  2018-01-12       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.