Literature DB >> 25316909

Measurement of maximum skin dose in interventional radiology and cardiology and challenges in the set-up of European alert thresholds.

J Farah1, A Trianni2, E Carinou3, O Ciraj-Bjelac4, I Clairand5, J Dabin6, C De Angelis7, J Domienik8, H Jarvinen9, R Kopec10, M Majer11, F Malchair12, A Negri13, L Novák14, T Siiskonen9, F Vanhavere6, Ž Knežević11.   

Abstract

To help operators acknowledge patient dose during interventional procedures, EURADOS WG-12 focused on measuring patient skin dose using XR-RV3 gafchromic films, thermoluminescent detector (TLD) pellets or 2D TL foils and on investigating possible correlation to the on-line dose indicators such as fluoroscopy time, Kerma-area product (KAP) and cumulative air Kerma at reference point (CK). The study aims at defining non-centre-specific European alert thresholds for skin dose in three interventional procedures: chemoembolization of the liver (CE), neuroembolization (NE) and percutaneous coronary interventions (PCI). Skin dose values of >3 Gy (ICRP threshold for skin injuries) were indeed measured in these procedures confirming the need for dose indicators that correlate with maximum skin dose (MSD). However, although MSD showed fairly good correlation with KAP and CK, several limitations were identified challenging the set-up of non-centre-specific European alert thresholds. This paper presents preliminary results of this wide European measurement campaign and focuses on the main challenges in the definition of European alert thresholds.
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2014        PMID: 25316909     DOI: 10.1093/rpd/ncu314

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Patient radiation doses and reference levels in pediatric interventional radiology.

Authors:  Bouchra Habib Geryes; Adeline Bak; Julie Lachaux; Augustin Ozanne; Nathalie Boddaert; Francis Brunelle; Olivier Naggara; Guillaume Saliou
Journal:  Eur Radiol       Date:  2017-02-16       Impact factor: 5.315

2.  Radiation-Induced Skin Injuries to Patients: What the Interventional Radiologist Needs to Know.

Authors:  Werner Jaschke; Matthias Schmuth; Annalisa Trianni; Gabriel Bartal
Journal:  Cardiovasc Intervent Radiol       Date:  2017-05-11       Impact factor: 2.740

3.  Vendor-independent skin dose mapping application for interventional radiology and cardiology.

Authors:  Marko Krajinović; Nikola Kržanović; Olivera Ciraj-Bjelac
Journal:  J Appl Clin Med Phys       Date:  2021-01-13       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.