Literature DB >> 25312782

Transcutaneous continuous carbon dioxide tension monitoring reduced incidence, degree and duration of hypercapnia during combined regional anaesthesia and monitored anaesthesia care in shoulder surgery patients.

Werner Baulig1, Marija Keselj, Barbara Baulig, Sandra Guzzella, Alain Borgeat, José Aguirre.   

Abstract

We studied the impact of transcutaneous continuous carbon dioxide tension (PtcCO2) monitoring on ventilation and oxygenation during monitored anaesthesia care (MAC) in patients scheduled for shoulder surgery with continuous interscalene block. 50 patients were randomised either to the intervention (I-group) or the control (C-group) group. In both groups MAC was performed using target controlled infusion of propofol and remifentanil. MAC regimen was adapted to PtcCO2 values in the I-group, whereas the C-group was blinded for these values. Primary outcome was the incidence, degree and duration of hypoventilation stages. In the I-group and the C-group the mean ± SD [range] of PtcCO2 and PaCO2 was 5.79 ± 0.84 [4.37] and 5.44 ± 0.59 [2.78] kPa, as well as 6.41 ± 1.17 [6.29] and 6.01 ± 0.96 [7.15] kPa. Periods of PtcCO2/PaCO2 > 6.5 kPa were 21.0 ± 35.7/1.2 ± 4.2 min in the I-group and 45.6 ± 40.0/18.6 ± 26.8 min in the C-group. Severe hypercapnia (PtcCO2 and/or PaCO2 > 7.5 kPa) was dected in 3/0 patients of the I-group and in 10/3 patients of the C-group. PtcCO2 and PaCO2 showed a strong correlation (r = 0.78), but only moderate agreement with a mean bias (LOA) of -0.37 (-1.69; +0.95) kPa showing an overestimation of the PaCO2. Sensitivity and specificity of PtcCO2 to detect changes of PaCO2 was 0.94 and 0.56, respectively. In no patient SpO2 or SaO2 values lower than 90% were measured. Despite a moderate agreement between PaCO2 and PtcCO2 the PtcCO2 monitoring significantly reduced incidence, degree and duration of hypercapnia in shoulder surgery patients with MAC.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25312782     DOI: 10.1007/s10877-014-9627-x

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  24 in total

1.  Overnight variability in transcutaneous carbon dioxide predicts vascular impairment in women.

Authors:  Jenni Aittokallio; Olli Polo; Jukka Hiissa; Arho Virkki; Jyri Toikka; Olli Raitakari; Tarja Saaresranta; Tero Aittokallio
Journal:  Exp Physiol       Date:  2008-02-22       Impact factor: 2.969

2.  The post-anesthesia recovery score revisited.

Authors:  J A Aldrete
Journal:  J Clin Anesth       Date:  1995-02       Impact factor: 9.452

3.  Transcutaneous arterial carbon dioxide pressure monitoring in critically ill adult patients.

Authors:  Pablo Rodriguez; François Lellouche; Jerome Aboab; Christian Brun Buisson; Laurent Brochard
Journal:  Intensive Care Med       Date:  2006-01-31       Impact factor: 17.440

4.  The revised digital transcutaneous PCO2/SpO2 ear sensor is a reliable noninvasive monitoring tool in patients after cardiac surgery.

Authors:  Regine Roediger; Beatrice Beck-Schimmer; Oliver M Theusinger; Denise Rusch; Burkhardt Seifert; Donat R Spahn; Edith R Schmid; Werner Baulig
Journal:  J Cardiothorac Vasc Anesth       Date:  2010-09-20       Impact factor: 2.628

5.  Detection of hypoventilation during deep sedation in patients undergoing ambulatory gynaecological hysteroscopy: a comparison between transcutaneous and nasal end-tidal carbon dioxide measurements.

Authors:  G S De Oliveira; S Ahmad; P C Fitzgerald; R J McCarthy
Journal:  Br J Anaesth       Date:  2010-04-23       Impact factor: 9.166

6.  Evaluation of the lateral modified approach for continuous interscalene block after shoulder surgery.

Authors:  Alain Borgeat; Alexander Dullenkopf; Georgios Ekatodramis; Ladislav Nagy
Journal:  Anesthesiology       Date:  2003-08       Impact factor: 7.892

7.  Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation.

Authors:  Jan H Storre; Boris Steurer; Hans-Joachim Kabitz; Michael Dreher; Wolfram Windisch
Journal:  Chest       Date:  2007-12       Impact factor: 9.410

8.  Transcutaneous carbon dioxide monitoring in spontaneously breathing, nonintubated patients in the early postoperative period.

Authors:  G Fanelli; M Baciarello; G Squicciarini; G Malagutti; M Zasa; A Casati
Journal:  Minerva Anestesiol       Date:  2008 Jul-Aug       Impact factor: 3.051

9.  Observational study of perioperative PtcCO2 and SpO2 in non-ventilated patients receiving epidural infusion or patient-controlled analgesia using a single earlobe monitor (TOSCA).

Authors:  A Kopka; E Wallace; G Reilly; A Binning
Journal:  Br J Anaesth       Date:  2007-07-25       Impact factor: 9.166

10.  Concordance between transcutaneous and arterial measurements of carbon dioxide in an ED.

Authors:  Samuel Delerme; Viviane Montout; Hélène Goulet; Amandine Arhan; Frederic Le Saché; Catherine Devilliers; Bruno Riou; Patrick Ray
Journal:  Am J Emerg Med       Date:  2012-07-12       Impact factor: 2.469

View more
  1 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: respiration.

Authors:  D S Karbing; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2015-12-30       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.