Literature DB >> 25306938

Gradient composite materials for artificial intervertebral discs.

Katarzyna Migacz1, Jan Chłopek1, Anna Morawska-Chochół1, Maciej Ambroziak2.   

Abstract

Composites with the gradient of Young's modulus constitute a new group of biomimetic materials which affect the proper distribution of stresses between the implant and the bone. The aim of this article was to examine the mechanical properties of gradient materials based on carbon fibre-polysulfone composite, and to compare them to the properties of a natural intervertebral disc. Gradient properties were provided by different orientation or volume fraction of carbon fibres in particular layers of composites. The results obtained during in vitro tests displayed a good durability of the gradient materials put under long-term static load. However, the configuration based on a change in the volume fraction of the fibres seems more advantageous than the one based on a change of the fibres' orientation. The materials under study were designed to replace the intervertebral disc. The effect of Young's modulus of the material layers on the stress distribution between the tissue and the implant was analyzed and the biomimetic character of the gradient composites was stated. Unlike gradient materials, the pure polysulfone and the non-gradient composite resulted in the stress concentration in the region of nucleus pulposus, which is highly disadvantageous and does not occur in the stress distribution of natural intervertebral discs.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25306938

Source DB:  PubMed          Journal:  Acta Bioeng Biomech        ISSN: 1509-409X            Impact factor:   1.073


  3 in total

Review 1.  What is the preclinical evidence on platelet rich plasma and intervertebral disc degeneration?

Authors:  Matteo Formica; Luca Cavagnaro; Carlo Formica; Milena Mastrogiacomo; Marco Basso; Alberto Di Martino
Journal:  Eur Spine J       Date:  2015-08-14       Impact factor: 3.134

Review 2.  Intradiscal platelet-rich plasma (PRP) injections for discogenic low back pain: an update.

Authors:  Michael Monfett; Julian Harrison; Kwadwo Boachie-Adjei; Gregory Lutz
Journal:  Int Orthop       Date:  2016-04-12       Impact factor: 3.075

3.  Structure and Properties of Polysulfone Filled with Modified Twill Weave Carbon Fabrics.

Authors:  Dilyus I Chukov; Sarvarkhodza G Nematulloev; Viсtor V Tсherdyntsev; Valerii G Torokhov; Andrey A Stepashkin; Mikhail Y Zadorozhnyy; Dmitry D Zherebtsov; Galal Sherif
Journal:  Polymers (Basel)       Date:  2019-12-30       Impact factor: 4.329

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.